Passive Air Sampling Kit

Restek / Probennahme

Passive Air Sampling Kits: Integrated • Provide accurate integrated sampling without a sampling pump. • Siltek®-treated components ensure accurate sampling of active components. • Excellent for sampling times from 0.5 hour to 125 hours. Restek’s passive air sampling kit incorporates all the hardware necessary to collect air samples and is easy to assemble for field sampling.* The improved filter design greatly reduces the number of potential leak sites. The passive air sampling kit is available in seven sampling flow ranges and in stainless steel or Siltek®-treated finish. The stainless steel kit is ideal to partner with the Restek TO-Can® air sampling canister for TO-14A and TO-15 methods. Use the Siltek®-treated version with the Restek SilcoCan® air sampling canister when collecting low-level volatile sulfur compounds, or other active compounds. 1. Veriflo® SC423XL flow controller This flow controller is the heart of the sampling train. It is a high-quality device designed to maintain a constant mass flow as the pressure changes from -30″ Hg to 7″ Hg (we recommend you stop sampling at or before 7″ Hg of vacuum). All wetted parts of the flow controller can be Siltek® treated. 2. Stainless steel vacuum gauge, 1/8″ NPT Fitted to the flow controller, the gauge monitors canister vacuum change during sampling. 3. 1/4-inch Siltek® sample inlet The 0.3 m x 1/4-inch tubing includes a stainless steel nut on the inlet end, to prevent water droplets from accumulating at the edge of the tubing, where they could be pulled into the sampling train. 4. 2-micron frit filter and washer Located prior to the critical orifice to prevent airborne particles from clogging the critical orifice. Replaceable. Available in stainless steel, or Siltek® treated for optimum inertness. 5. Interchangeable critical orifice An interchangeable ruby critical orifice allows you to control the flow with very high precision. Note: All fitting connections are 1/4″ tube, except where noted. *Air sampling canisters sold separately.

1.472,00 €
Artikel-Nr. Material Orifice Bohrung Zoll Flussrate (mL/min) Einzelpreis Best.Einh. Menge
Preis
22100 Edelstahl 0,0090 80-340 1.290,00 € St
1.290,00 €
22101 Siltek-behandelt 0,0090 80-340 1.499,00 € St
1.499,00 €
24160 Siltek-behandelt 0,0012 2-4 1.472,00 € St
1.472,00 €
24161 Siltek-behandelt 0,0016 4-8 1.472,00 € St
1.472,00 €
24162 Siltek-behandelt 0,0020 8-15 1.472,00 € St
1.472,00 €
24163 Siltek-behandelt 0,0030 15-30 1.514,00 € St
1.514,00 €
24164 Siltek-behandelt 0,0060 30-80 1.514,00 € St
1.514,00 €
24165 Edelstahl 0,0012 2-4 1.266,00 € St
1.266,00 €
24166 Edelstahl 0,0016 4-8 1.266,00 € St
1.266,00 €
24167 Edelstahl 0,0020 8-15 1.266,00 € St
1.266,00 €
24168 Edelstahl 0,0030 15-30 1.266,00 € St
1.266,00 €
24169 Edelstahl 0,0060 30-80 1.266,00 € St
1.266,00 €
24216 Edelstahl 0,0008 0,5-2 1.167,00 € St
1.167,00 €
24217 Siltek-behandelt 0,0008 0,5-2 1.472,00 € St
1.472,00 €
Artikel-Nr. Name Orifice Bohrung Zoll VE Material Flussrate (mL/min)
22100 0,0090 1 Edelstahl 80-340
22101 0,0090 1 Siltek-behandelt 80-340
24160 0,0012 1 Siltek-behandelt 2-4
24161 0,0016 1 Siltek-behandelt 4-8
24162 0,0020 1 Siltek-behandelt 8-15
24163 0,0030 1 Siltek-behandelt 15-30
24164 0,0060 1 Siltek-behandelt 30-80
24165 0,0012 1 Edelstahl 2-4
24166 0,0016 1 Edelstahl 4-8
24167 0,0020 1 Edelstahl 8-15
24168 0,0030 1 Edelstahl 15-30
24169 0,0060 1 Edelstahl 30-80
24216 0,0008 1 Edelstahl 0,5-2
24217 0,0008 1 Siltek-behandelt 0,5-2
Passive Air Sampling Kits: Integrated • Provide accurate integrated sampling without a sampling pump. • Siltek®-treated components ensure accurate sampling of active components. • Excellent for sampling times from 0.5 hour to 125 hours. Restek’s passive air sampling kit incorporates all the hardware necessary to collect air samples and is easy to assemble for field sampling.* The improved filter design greatly reduces the number of potential leak sites. The passive air sampling kit is available in seven sampling flow ranges and in stainless steel or Siltek®-treated finish. The stainless steel kit is ideal to partner with the Restek TO-Can® air sampling canister for TO-14A and TO-15 methods. Use the Siltek®-treated version with the Restek SilcoCan® air sampling canister when collecting low-level volatile sulfur compounds, or other active compounds. 1. Veriflo® SC423XL flow controller This flow controller is the heart of the sampling train. It is a high-quality device designed to maintain a constant mass flow as the pressure changes from -30″ Hg to 7″ Hg (we recommend you stop sampling at or before 7″ Hg of vacuum). All wetted parts of the flow controller can be Siltek® treated. 2. Stainless steel vacuum gauge, 1/8″ NPT Fitted to the flow controller, the gauge monitors canister vacuum change during sampling. 3. 1/4-inch Siltek® sample inlet The 0.3 m x 1/4-inch tubing includes a stainless steel nut on the inlet end, to prevent water droplets from accumulating at the edge of the tubing, where they could be pulled into the sampling train. 4. 2-micron frit filter and washer Located prior to the critical orifice to prevent airborne particles from clogging the critical orifice. Replaceable. Available in stainless steel, or Siltek® treated for optimum inertness. 5. Interchangeable critical orifice An interchangeable ruby critical orifice allows you to control the flow with very high precision. Note: All fitting connections are 1/4″ tube, except where noted. *Air sampling canisters sold separately.

Kontakt-Formular

Sie haben Fragen zu unserem Shop oder einem unserer Produkte?

Bitte füllen Sie Ihre Kontaktdaten und Ihr Anliegen aus, wir melden uns umgehend mit allen gewünschten Informationen.

Katalogbestellung

Sie haben Fragen zu unserem Shop oder einem unserer Produkte?

Bitte füllen Sie Ihre Kontaktdaten und Ihr Anliegen aus, wir melden uns umgehend mit allen gewünschten Informationen.

Sind Sie Firmen- oder Privatkunde?