CO2 Sensor InPro5000i/12/220
In-Line CO2 Measurement in Biotechnology. • The InPro 5000i 12/220 is an on-line carbon dioxide sensor with ISM that allows for accurate measurement and control of dissolved CO2 in biopharmaceutical applications. It is based on the widely accepted Severinghaus principle of CO2 measurement. • In situ measurement of CO2 with the InPro 5000i 12/120 allows immediate reaction to CO2 changes to help maximize productivity in cell culture. • Sterilized and autoclaved: The InPro 5000i 12/120 is fully SIP resistant and autoclavable. It is made of FDA compliant materials, making it optimal for pharmaceutical processes. • This CO2 sensor uses a membrane body concept to dramatically limit maintenance time. The inner body, a pH electrode, can easily be replaced on site. • This CO2 sensor uses Intelligent Sensor Management (ISM) technology. This provides pre-batch diagnostics for the best measurement performance and full traceability for complete documentation. The Plug and Measure feature supports seamless integration. Specifications: Measuring range: Concentration: 10 to 1000 mbar pCO2 Measuring range (concentration): 0.145 to 14.5 psig pCO2 Accuracy: ± (10% of measured value + 10mbar) Hygiene/Biocompatibility Approvals: EHEDG EL Class 1, USP Class VI/FDA/USP Class 6 IP protection class: IP67 Autoclavable/sterilizable: Yes CIP capable: Yes Certificates and Approvals: Quality Certificate, Material Certificate 3.1, Surface Finish Certificate, FDA/USP Class IV Measurement parameters: carbon dioxide Cable connection: K8S ISM (digital) or analogue: ISM (digital) Wetted metallic material: 316L stainless steel Surface roughness of the wetted parts (2): N5/Ra16 (Ra = 0.4 μm/16 μin) Sensor diameter (2): 12mm O-ring material: Viton®, silicone Measuring temperature range: 0°C – 60°C Mechan. Temp. resistance: 0°C – 135°C Operating pressure (bar): 0.200 to 2,000 bar Design pressure: 3 bar CO2 operating range: 10 mbar – 1,000 mbar Pressure range during measurement: 0.2 bar – 2 bar Primary media/application: pharmaceuticals/life science production Process connection: Pg 13.5 Response time: T90 = < 120 s, air to CO2 at 25 °C Sensor length: 220 mm Membrane material in contact with media: PTFE Measuring technology: Potentiometric (Severinghaus) Plug design: Straight Feedback geben Seitenleisten
Article nr. | Name | PackageContent | Genauigkeit | Messbereich | Anschluss | Länge mm | Typ | Ø mm |
---|---|---|---|---|---|---|---|---|
30019005 | 1 | ± (10 % des Messwerts + 10 mbar) | 10 bis 1000 mbar Pco2 (Konzentration) / 0,145 bis 14,5 psig Pco2 (Konzentration) | K8S | 220 | CO2 Sensor InPro5000i/12/220 | 12 |