Innovative Integra-Guard® Columns Get the protection without the connection! • No leaks for a more robust method. • No column connections for easier, faster maintenance. • No peak distortions due to connector dead volume and thermal capacity. For analysts who find it inconvenient to make a leak-free connection between the guard column and the analytical column, we offer Integra-Guard® columns. These innovative columns incorporate both a guard column and an analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems! The guard column section is marked separately from the analytical column using high-temperature string. A wide variety of our Integra-Guard® capillary columns are listed here. The Integra- Guard® column is so economical that we challenge you to compare our price against that of a conventional connection, even if you assemble it yourself. If you are currently using a guard column, or are considering using one, call today and ask about Integra- Guard® columns.
ShinCarbon ST Micropacked Columns SilcoSmooth Stainless Steel •Separate permanent gases, including carbon monoxide and carbon dioxide, without cryogenic cooling. •Rapid separations of permanent gas/light hydrocarbon mixtures. •Excellent compatibility with most GC detectors—minimal bleed, minimal baseline rise. •Preconditioned, less than 30 minutes to stabilize. •Maximum temperature of 280 °C/300 °C.
DiatoSorb Diatomaceous Earth Columns (bonded stationary phase packed columns) • Low bleed levels. • Longer column lifetimes. • Short conditioning times.
MXT-Biodiesel TGRetention Gap, 2m x 0.53mm
Rxi®-5Sil MS Columns (fused silica) (low-polarity phase; Crossbond® 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane) • Engineered to be a low-bleed GC-MS column. • Excellent inertness for active compounds. • General-purpose columns—ideal for GC-MS analysis of semivolatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons. • Temperature range: -60 °C to 350 °C. The Rxi®-5Sil MS stationary phase incorporates phenyl groups in the polymer backbone. This improves thermal stability, reduces bleed, and makes the phase less prone to oxidation. Rxi®-5Sil MS columns are ideal for GC-MS applications requiring high sensitivity, including use in ion trap systems.
Rt®-Alumina BOND/KCl Columns (fused silica PLOT) (KCl deactivation) • Restek’s lowest polarity alumina column. • Low moisture sensitivity reduces the need for frequent regeneration. • Acetylene elutes before n-butane. • Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene. • Stable to 200 °C.
Rtx-BAC2 Columns (fused silica) proprietary Crossbond phase • Application-specific columns for blood alcohol analysis—achieve baseline resolution in less than 3 minutes. Also excellent for abused inhalant anesthetics, γ-hydroxybutyrate (GHB)/γ-butyrolactone (GBL), glycols, and common industrial solvents. • Rtx-BAC2 confirmation column provides four elution order changes under the same conditions. • Stable to 260 °C.
2abc Refinery Gas Column Set (Packed Column) •Special Columns for Unsaturated Light Hydrocarbons •Faster separations of C1 to C4 hydrocarbons. •This 3-column set is finely tuned to resolve light hydrocarbons. When used in the proper valving system, it will elute C5+ hydrocarbons ahead of C1 through C4 hydrocarbons.
Rxi®-1ms: Secondary Columns for GCxGC What do Rxi® columns mean to you? Three things: •Ultra-low bleed. •Exceptional inertness. •Reproducible performance, column after column. Rxi® fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column characteristics assures Rxi® columns will have long lifetimes. The Restek chemists also have developed a stable, reproducible manufacturing process, so that Rxi® columns will meet your needs every time you install a new column. •Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses. •General purpose columns. •Temperature range: -60 °C to 330/350 °C (bleed tested temperature/maximum operating temperature).
Innovative Integra-Guard Columns Get the protection without the connection! • These innovative columns incorporate both guard column and analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems! • The guard column section is marked separately from the analytical column, using high-temperature string.
MXT®-502.2 Columns (Siltek®-treated stainless steel) (proprietary Crossbond® diphenyl/dimethyl polysiloxane phase) • Application-specific columns with unique selectivity for volatile organic pollutants, cited in U.S. EPA Method 502.2 and in many gasoline range organics (GRO) methods for monitoring underground storage tanks. Excellent separation of trihalomethanes; ideal polarity for light hydrocarbons and aromatics. • Temperature range: -20 °C to 320 °C. • 4.5" standard coil diameter. An MXT®-502.2 column will enable you to quantify all compounds listed in U.S. EPA Methods 502.2 or 524.2, whether you use a mass spectrometer or a PID in tandem with an ELCD. The diphenyl/dimethyl polysiloxane based MXT®-502.2 stationary phase provides low bleed and thermal stability to 320 °C. A 105-meter column can separate the light gases specified in EPA methods without subambient cooling.
Innovative Integra-Guard Columns Get the protection without the connection! • These innovative columns incorporate both guard column and analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems! • The guard column section is marked separately from the analytical column, using high-temperature string.
Rtx®-Dioxin2 Columns (fused silica) (proprietary Crossbond® phase) • Isomer specificity for 2,3,7,8-TCDD and 2,3,7,8-TCDF achieved with one GC column. • Thermally stable to 340 °C for longer lifetime. • Unique selectivity for toxic dioxin and furan congeners allows use as a confirmation GC column.
Rtx®-624 Columns (fused silica) (low- to midpolarity phase) • Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. • Temperature range: -20 °C to 240 °C. • Equivalent to USP G43 phase. The unique polarity of the Rtx®-624 column makes it ideal for analyzing volatile organic pollutants. Although the Rtx®-502.2 column is recommended in many methods, the Rtx®-624 column offers better resolution of early eluting compounds. The Rtx®-624 phase produces greater than 90% resolution of the first six gases in EPA Methods 8260 and 524.2. This stationary phase is especially well-suited for EPA Method 524.2 since it resolves 2-nitropropane from 1,1-dichloropropanone, which share quantification ion m/z 43 and must be separated chromatographically.
•Application-specific columns for flavor and fragrance compounds, specially tested. •True nonbonded Carbowax® 20M polarity. •Temperature range: 60 °C to 220 °C.
Innovative Integra-Guard® Columns Get the protection without the connection! • No leaks for a more robust method. • No column connections for easier, faster maintenance. • No peak distortions due to connector dead volume and thermal capacity. These innovative columns incorporate both a guard column and an analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems! The guard column section is marked separately from the analytical column using high-temperature string.
Metal MXT® PLOT Columns Advantages of metal MXT® PLOT columns include: • Can be made in small coil diameters—perfect for tight spaces. • Rugged material withstands rough handling and shock. • Designed for robust performance in process GCs and field instruments. • Available in 3.5"-coil diameter or 7"-diameter, 11-pin cage. Restek® chemists have developed technology that allows many of our popular PLOT columns to be made on Siltek®-treated stainless steel. These columns have the same characteristics and performance as fused silica PLOT columns, but offer additional benefits for process GCs and field applications as they are virtually unbreakable and can be coiled into very small diameters.
Rtx-CLP Cap. Column Kit11139/11324/10027 w/Angled Y Presstight
Low-Pressure GC (LPGC) Column Kit Leverage Your MS Vacuum to Significantly Speed Up Separations • 3x faster multiresidue pesticides analysis in foods. • Factory-coupled, leak-free kit makes setting up LPGC as simple as a column change. • Ideal for speeding up GC-MS and GC-MS/MS methods. • Integrated transfer line reduces background and stabilization time. Includes: Factory-coupled restrictor column (5 m x 0.18 mm ID) and Rtx-5ms analytical column (15 m, 0.53 mm ID, 1 µm plus 1 m integrated transfer line on the outlet end)
Chromosorb Micropacked GC Columns • Increased efficiency over traditional packed columns. • Higher capacity than PLOT columns. • Made from inert, flexible SilcoSmooth tubing. • Wide range of packings available. • Standard coils fit all instruments. No special instrument configurations required.
MXT-Biodiesel TG Columns (Siltek-treated stainless steel) • Fast analysis times and sharp mono-, di-, and triglyceride peaks. • Temperature range: -60 to 430 °C
Rxi-SVOCms Columns (fused silica) Proprietary 5% phenyl-type phase • Column chemistry optimized specifically to give premium performance for semivolatiles in complex matrices. • Long column lifetime—restore performance with a quick trim instead of a time-consuming replacement. • Outstanding inertness keeps calibrations passing and samples running. • Excellent resolution of critical pairs for improved accuracy. • Consistent column-to-column performance. • Engineered to be a low-bleed GC-MS column. • Temperature range: -60 °C to 340 °C. • Equivalent to USP G27 and G36 phases.
XTI-5 Cap. Column 30m 0.25mm ID 0.25um with 5m Integra-Guard Column
Stx-CLP Cap. Column Kit 0.32mmID 11544/11444 /10027 With Angled Y Presstight Connector
Innovative Integra-Guard Columns Get the protection without the connection! • These innovative columns incorporate both guard column and analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems! • The guard column section is marked separately from the analytical column, using high-temperature string.
Rt®-Alumina BOND/Na2SO4 Columns (fused silica PLOT) (Na2SO4 deactivation) • Acetylene and propadiene elute after butanes. • Best separation for butene isomers (impurities in butene streams). • Methyl acetylene elutes after 1,3-butadiene. • Cyclopropane (impurity in propylene) elutes well before propylene. • Stable to 200 °C.
MXT-Alumina BOND/MAPD Columns (Siltek-treated stainless-steel PLOT) • Optimized deactivation produces maximum response when analyzing trace levels of acetylene, methyl acetylene, and propadiene. • Stable response factors make this column ideal for process-type applications where recalibration must be minimized. • High loadability reduces peak tailing and improves separations. • Extended temperature range up to 250 °C for fast elution of high molecular weight (HMW) hydrocarbons and accelerated column regeneration following exposure to water. • Temperature range: -60 to 250 °C. MXT-Alumina BOND/MAPD PLOT columns are made specifically for the analysis of petrochemicals and downstream products such as ethylene, propylene, butylenes, and butadiene! No guarantee for loose particles Non-returnable/Non-refundable
Micropacked GC Column TCEP-D4815 0.56m 0.75mm ID Pack of 6
MXT-Biodiesel TG Columns (Siltek-treated stainless steel) • Fast analysis times and sharp mono-, di-, and triglyceride peaks. • Temperature range: -60 to 430 °C
HT8-PCB GC Capillary Column 8% Phenyl (equiv.) Polycarborane siloxane • Unique ultra high temperature column optimizes for 209 PCB congener separations • Optimized for 209 PCB congener separations
BP5MS GC Capillary Column •Perfect for your 5% GC-MS analysis. •Optimized Silphenylene content for general purpose MS analyses. Application Areas: 5% GC-MS analyses
BPX5 GC Capillary Column •High temperature, •General Purpose GC column - suitable for over 80% of all routine analyses performed by gas chromatography, •Very Low Bleed - ideal for trace analysis , •Non-Polar , •Extremely inert , •Ideal for GC-MS . Application Areas: Ultra trace analyses, pesticides/herbicides, hydrocarbons, solvents, phenols, amines, GC/MS and other specific detector applications
BPX90 GC Capillary Column •Unique bonded phase •Highly Polar •Thermally Stable Application areas: ideal for fast separation of fragrances, aromatics, petrochemical, pesticides, PCBs and isomers of Fatty Acid Methyl Esters (FAMEs)
BPX1- Simulated Distillation GC Capillary Column 100% Dimethyl Polysiloxane •Non-polar column •Dimensionally stabilized phase •Low bleed •Specifically designed for high temperature hydrocarbon analysis •Ideal for simulated distillation Application Areas: ASTM methods D2887 and D6532
SolGel-WAX GC Capillary Column •The world's highest temperature wax phase •Bonded polyethylene glycol •Very robust high-temperature column •Less susceptible to damage by oxygen than conventional wax phases •Polar phase •Low bleed and inert Application Areas: Recommended for highly active compounds
BP10 GC Capillary Column •Ideal for organochlorine pesticides analysis, •Highly Inert, •Low bleed. Application Areas: Environmental analyses (EPA methods 608 and 8081), pesticides/herbicides, drugs of abuse, pharmaceuticals
35% Phenyl Polysilphenylene-siloxane •Mid polarity column •Ideal for confirmational analysis •Inert •Equivalent to USP phase G42 •High temperature •Low bleed •Pharmaceutical specialist Application Areas: Environmental analyses, pesticides/herbicides, drugs of abuse, pharmaceuticals, polynuclear aromatic hydrocarbons, GC/MS applications
BP5 GC Capillary Column •Excellent general purpose GC column, •Low bleed, •Non-polar, •High temperature. Application Areas: Aromatics, pesticides, herbicides, drugs of abuse, hydrocarbons, GC/MS applications
CYDEX-B GC Capillary Column Permethylated Beta Cyclodextrin (Chiral) •Separation of Chiral Compounds Application Areas: Separation of enantiomeric compounds found in natural products
HT8 GC Capillary Column •High temperature •Low Bleed •Preferred column for polychlorinated biphenyl (PCB) compounds •Separates PCB's on ortho ring substitution as well as boiling point •Ideal for environmental analysis Application Areas: PCB congener alayses, nitro-substituted aromatics, polynuclear aromatic hydrocarbons, pesticides/herbicides
HT5 GC Capillary Column •Ultra High temperature column range •Unique phase - no equivalent phases •Ideal for simulated distillation applications (petroleum industry) Application Areas: Simulated distillation, general hydrocarbon profiles, pesticides/herbicides, GC/MS applications
BP1 GC Capillary Column •Classic dimethyl polysiloxane technology with high temperature cross-linking, •Excellent general purpose GC column, •Low Bleed, •Non-polar, •Suitable for all routine analyses. Application areas: suitable for analysis of hydrocarbons, aromatics, pesticides, phenol, herbicides, amines Suitable replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.
BP624 GC Capillary Column •US EPA 624 optimized column •designed for volatiles analysis •Ideal for EPA624, SW-846 and 8240/8260 methods •Ideal for USP G43 method Application Areas: EPA method 624, drinking water volatiles, chlorinated hydrocarbons, solvents
SolGel-1ms GC Capillary Column A robust, inert, high temperature, non-polar phase for use with mass spectrometers. •Highly Inert •Less Bleed - Better MS library identification •Less bleed - Less ion source maintenance •Less Bleed - Better sensitivity •Can also be used for all non-MS detectors Application Areas: recommended for highly active compounds
BPX70 GC Capillary Column 70% Cyanopropyl Polysilphenylene-siloxane • High temperature • Custom designed for separation of fatty acid methyl esters (FAMEs) • Industry standard column for FAME analysis • Ideal for cis/trans isomer separation • Polar phase Application areas: Fatty acid methyl esters, carbohydrates, pharmaceuticals, GCMS applications. Operating temperature: 0.2-0.5 μm film thickness: 50°C to 250/260°C. Suitable replacement for: CP-Sil 88, DB-23, Rtx-2330, SP-2330, SP-2380, VF-23ms, ZB-FAME.