Thermo Scientific™ TRACE TR-50MS GC Columns are mid-polarity columns well-suited to GC/MS applications. • Mid-polarity phase, 50% Phenyl polysilphenylene-siloxane • Low-bleed decreases MS contamination • Particularly useful for applications requiring a higher temperature and more polarity than a 5% phenyl column • Column inertness results in minimal peak tailing and decreased breakdown of sensitive samples • Similar to: OV-17, SP-2250, DB-17, DB-17ms, DB-17ht, BPX50, Rtx-50, SPB-50, HP-50+, HP-17, AT50, RSL-300, PE-17, CC-17, 007-17(MPS-50), SPB-17, ZB-50 Recommended for: • Herbicides • Drugs of Abuse • EPA 604, 608, 8060, 8081 • Pharmaceuticals
The column has a strongly cross-linked phase with an operating temperature limit of 400°C. Its stable low-bleed profile facilitates consistent background subtraction, which is common practice in these analyses. Specifications: • Nonpolar phase, 100% dimethyl polysiloxane • Optimized for simulated distillation analysis • High temperature limits (400˚C for films <1.0μm; 370˚C for 2.65μm films) • Strongly cross-linked Applications: • High molecular weight hydrocarbons • Simulated distillation • ASTM D2887, D6532 Recommended For: • Simulated distillation • Petroleum Alternative Uses: • Xylenes Similar To: DB-HT Sim Dis, DB-2887, BPX1, Rtx™-2887, HP-1, Petrocol™ 2887, Petrocol™ EX2887
Thermo Scientific™ TRACE TR-V1 GC-Säulen sind Dickfilmsäulen mittlerer Polarität. • Phase mittlerer Polarität, 6 % Cyanopropylphenyl Polysiloxan • Dickfilm-Säule zur Analyse flüchtiger Analyten • Geringes Bluten, geeignet für MS-Detektion • Ähnlich: DB-624, BPX Volatiles, Rtx Volatiles, VOCOL 56, OV-624, AT-624, HP-VOC, CP-Select 624CB, 007-624, ZM-624 Empfohlen für: • Flüchtige organische Verbindungen • Alkohole • EPA 502.2, 608 und 624
Specifications: • Mid-polarity phase (14% cyanopropylphenyl, 86% dimethyl polysiloxane) • Fully characterized for long-term reproducibility, column-to-column consistency and low-bleed • Optimal for confirmation analysis • Equivalent to USP G46 phase • Similar to: Rtx-1701, DB-1701, HP-1701, SPB-1701, VF-1701, CP-Sil 19 CB Recommended for: • Alcohols • Pesticides • Oxygenates • PCB cogeners • Aroclor mixes
Specifications: • Polar phase, polyethylene glycol • Highly cross-linked and fully deactivated • Solvent washable Applications: • Esters • Alcohols • Ketones • Glycols • Aromatic isomers Similar To: DB-Wax, BP20, Rtx™-Wax, Stabilwax™, HP20M, HP-Wax, HP-INNOWax, SUPELCOWAX™ 10, AT™-Wax, Nukol™, CP Wax52CB, SUPEROX II, Carbowax™, PE-WAX, ZBWAX
For high-polarity separations as part of GC/MS analysis, choose the low-bleed, high polarity Thermo ScientificTM TRACETM TR-WaxMS GC Column. The TRACE TR-WaxMS column is manufactured using a proprietary bonding technique that minimizes bleed and extends the maximum operating temperature (260 to 280 ̊C). Engineered for Superior Performance: • Polar phase, polyethylene glycol • Proprietary bonding method for expanded operating temperatures • Extremely low-bleed for improved sensitivity and library matches • High stability with oxygen and water Applications: • Aromatic hydrocarbons • Food additives • Essential oils • Alcohols • Esters • Aldehydes • Ketones Similar To: DB-Wax, Rtx™-Wax, Stabilwax™, HP20M, BP20, HP-Wax, HP-INNOWax, SUPELCOWAX™ 10, AT™-Wax, Nukol™, CP Wax 52CB, ZB-Wax
Thermo Scientific™ TraceGOLD TG-1301MS GC Columns provide low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS. • Low to mid-polarity phase, 6% cyanopropylphenyl/94% dimethyl polysiloxane • Long lifetime • Excellent inertness • Equivalent to USP G43 phase • Similar to: Rtx-1301, DB-1301, BP-624, HP-1301, HP-624, SPB-1301, SPB-624, VP-1301, BF-624ms, CP-1301, CP-Select 624 CB Recommended for: • Alcohols • Volatile organics • Oxygenates • Residual solvents
Thermo Scientific™ TraceGOLD TG-35MS AMINE GC Columns utilizes a chemically altered tubing surface to reduce peak tailing and eliminates the need for column priming when analyzing amines and other basic compounds. • Midpolarity phase, 35% diphenyl/65% dimethyl polysiloxane • Developed for analysis of active basic compounds without derivatization • Also allows analysis of neutral compounds and adsorptive compounds with oxygen groups susceptible to hydrogen bonding • Low bleed at maximum operating temperature Recommended for: • Amines including alkylamines, diamines, triamines and ethanolamines • Nitrogen-containing heterocyclics
Thermo Scientific™ TraceGOLD TG-35MS Columns offers a higher phenyl content providing useful elution order and retention time changes. • Mid-polarity phase, 35% diphenyl/65% dimethyl polysiloxane • Equivalent to USP G42 phase • Similar to Rtx™-35, BD-35, HP-35, SPB-35, SPB-608 Recommended for: • Organochlorine pesticides and herbicides • Pharmaceuticals • PCB cogeners • Aroclor mixes • Sterols • Rosin acids • Phthalate esters
TRACE TR-BioDiesel (M); for determination of residual methanol content in biodiesel according to EN Method 14110
TRACE TR-BioDiesel (G); for the analysis of total glyceride content according to EN Method 14105
TRACE TR-BioDiesel (F); for the analysis of FAME content in biodiesel according to EN Method 14103
TG-BIODIESELMT 15MX0.32MM coating: BR-BIODIESEL DF=0.10UM with Guard Column. Used for glycerides analysis according ASTM D6584.
Thermo Scientific™ TRACE™ GC Columns for Drugs of Abuse. TRACE TR-DoA 5MS: Widely used for the analysis and determination of a range of toxicological target compounds including amphetamines, codeine, and morphine.
Thermo Scientific™ TRACE™ GC Columns for Drugs of Abuse. TRACE TR-DoA 35MS: Ideal for the determination of carboxy-THC because of its higher polarity, making it the recommended column for use in drug testing labs for the confirmation of THC
Columns Tailored Specifically for Dioxins and PCBs: • TRACE TR-Dioxin 5MS: dioxin and furan testing • TRACE TR-PCB 8MS: high-resolution GC/MS analysis of PCBs • Excellent Quality and Reproducibility • Low bleed, even at elevated temperatures • Outstanding robustness for difficult separations • Reliable and reproducible performance
Identify organophosphate and organochlorine pesticides with high performance, sensitivity, and reproducibility using the Thermo Scientific™ TRACE™ GC Columns for Pesticides. These columns are specifically designed and tested to meet the most stringent requirements for the analysis of pesticides and herbicides. Excellent Quality and Reproducibility: • Low bleed decreases MS contamination • Innovative design facilitates use at higher temperatures • Column inertness results in minimal peak tailing and decreased breakdown of sensitive samples Alternative Uses: • Chlorinated aromatics • Plant sterols • Pyrethroids
Thermo Scientific™ Hydrogold Column Guard
Thermo Scientific™ TraceGOLD TG-5HT GC Columns offer extended operation up to 400°C, ideal for high temperature GC applications. • Low polarity, 5% diphenyl/95% dimethyl polysiloxane • Lower bleed and better inertness than comparable high-temperature columns • Special design of fused silica tubing extends column lifetime by up to 40% • Similar to Rxi™-5HT, BD-5HT, VF-5HT, ZB-5HT Recommended for: • Phenols • Residual solvents • Drugs of abuse • Semivolatiles • Pesticides • PCBs • Solvent impurities
TG-5MT 053MM X30UM
Thermo Scientific™ TraceGOLD™ TG-5MT Metal GC Columns provide greater stability and inertness at higher temperatures and when working with very active compounds. Offers greater robustness under increased stress. • Can be used at elevated temperatures without risk of bleeding or damage • Excellent inertia when working with highly active compounds • Robust under load
Thermo Scientific™ TraceGOLD TG-5SilMS GC Columns incorporate phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation. • Low polarity, silarylene phase with selectivity comparable to 5% diphenyl/95% dimethyl polysiloxane • Designed for low bleed and outstanding inertness • Similar to DB-5MS, VF-5ms, CP-Sil 8 Low-Bleed/MS, Rxi-5Sil MS, BPX5, ZB-5ms, Optima-5MS, SLB-5 Recommended for: • GC/MS applications using ion-trap systems • Polycyclic aromatics • Hydrocarbons including chlorinated hydrocarbons • Phthalates • Phenols • Amines • Organophosphates
TG-PEST5MS GC Column 20m x 0.18mmx0.2µm
GC Column TraceGOLD TG-1HT, 0.1 µm, 0.32 mm x 15 m
Perform fast analysis of multi-class contaminants including pesticides, PCB, PAHs, and PBDE with Thermo Scientific™ TraceGOLD™ TG-Contaminants GC columns. These highly inert capillary columns combine thermal stability with a unique selectivity to ensure excellent chromatographic peak shapes and sensitivity. Key Benefits • Perform multi-class contaminant analysis on one column • Optimized efficiency and selectivity for high throughput • Robust with a maximum temperature of 360°C
TG-FAME GC Column 50m x 025mm x 020µm
Thermo Scientific™ TraceGOLD™ TG-5SILMS Guard GC Columns with SafeGuard offer the benefit of an integrated SafeGuard for extended column lifetime. Using a guard column with a TraceGOLD TG-5SILMS GC column will lead to greater consistency in results over a longer period of time. • With integrated SafeGUARD • Available in a range of phases Spcifications: • Low polarity, silarylene phase with selectivity comparable to 5% diphenyl/95% dimethyl polysiloxane • Designed for low bleed and outstanding inertness • Similar to DB-5MS, VF-5ms, CP-Sil 8 Low-Bleed/MS, Rxi-5Sil MS, BPX5, ZB-5ms, Optima-5MS, SLB-5 Recommended for: • GC/MS applications using ion-trap systems • Polycyclic aromatics • Hydrocarbons including chlorinated hydrocarbons • Phthalates • Phenols • Amines • Organophosphates
TG-Packed Column PP-Q 80/100 2M, 2.0 mm ID 1/8IN OD NICKEL GEN CONFIG NOC KIT-D
TG-Packed Column HS-Q 80/100 10.0FT 2.0 mm ID 1/8ID OD SILCO HP STD HP CPMFIG OC INV: 2.0IN OUTV:1.5IN NO KIT
TG-Micropacked Column TCEP-D4815 0.56 m, 0.75 mm ID
TG-Packed Column 30.0% DC-200/500 CHR-PNAW 80/100 0.4 m 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC NO KIT
TG-Packed Column 30.0% DC-200/500 CHR-PNAW 80/100 7.3 m 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC NO KIT
TG-Packed Column MS-5A 80/100 8m 2.0 mm ID 1/8IN OD SILCO GEN CONFIG NOC KIT-D
TG-Packed Column PP-N 80/100 1.83m 2.0 mm ID 1/8IN OD SILCO HP STD HP CONFIGG OC INV:2.0IN OUTV:1.5IN NO KIT
TG-Packed Column MS-5A 60/80 1.83m 2.0 mm ID 1/8IN OD SILCO HP STD HP CONFIG OC INV:2.0IN OUTV:1.5IN NO KIT
Thermo Scientific™ TraceGOLD TG-5MS AMINE GC Column enables analysis of ppm levels of amines without column priming. • Low polarity phase, 5% diphenyl/95% dimethyl polysiloxane • Tubing surface is chemically altered to reduce tailing of active basic compounds • Also allows analysis of neutral or weakly acidic compounds (e.g., phenols) and compounds susceptible to hydrogen bonding • Low bleed at maximum operating temperature Recommended for: • Amines and other basic compounds, including alkylamines, diamines, triamines, ehtanolamines • Nitrogen-containing heterocyclics
Specifications: • Low polarity phase, 5% diphenyl/95% dimethyl polysiloxane • Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity • Exceptional inertness ideal for analysis of active compounds • Equivalent to USP G27 phase • Similar to Rxi™-5ms, DB-5, HP-5, HP-5ms, Ultra-2, SPB-5, Equity-5, CP-Sil 8 Recommended for: • Semivolatiles • Phenols • Amines • Residual solvents and solvent impurities • Drugs of abuse • Pesticides • PCB cogeners • Aroclor mixes
TG-Packed Column 30.0 DC-200/500 CHR-PAW 60/80 2.0 ft 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC KIT-B
TG-Packed Column MS-13X 45/60 4.0 ft. 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC KIT-B
TG-Packed Column 30.0% DC-200/500 CHR-PAW 60/80 35.0 ft 2.0 mm ID 1/8IN OD KIT-B
TG-Packed Column 1.0% OV-101 CHR-GAW 100/120 2.0ft 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC KIT-B
TG-Packed Column HS-D 80/100 2.0m 2.0 mm ID 1/8IN OD SILCO GEN CONFIG NOC KIT-B
TG-Packed Column HS-N 80/100 0.5m 2.0 mm ID 1/8IN OD SILCO GEN CONFIG NOC KIT-B
TG-Packed Column PP-Q 80/100 0.5m 2.0 mm ID 1/8IN OD SILCO GEN CONFIG NOC KIT-B
TG-Packed Column HS-Q 80/100 0.5m 2.0 mm ID 1/8IN OD GEN CONFIG NOC KIT-D
TG-Packed Column PP-N 80/100 1.83m 2.0 mm ID 1/8IN OD GEN CONFIG NOC KIT-D
TG-Packed Column MS-5A 80/100 1.83m 2.0 mm ID 1/8IN OD GEN CONFIG NOC KIT-D
TG-Packed Column 1m x 2.0mmID x1/8IN OD MS-5A 60/80 SILCO GEN CONFIG PRECOND NOC KIT C 6IN COIL
TG-Packed Column 4m x 2.0mmID x 1/8IN OD MS-5A 60/80 SILCO GEN CONFIG PRECOND NOC KIT C 6 IN COIL
TG-Micropacked Column 1.5m x 1.0mmID x 1/16IN OD MS-5A 80/100 SILCO PRECOND NOC 6IN COIL