GC capillary columns

Your filters:
999 Found products
Products per page

HP-PLOT Al2O3 M GC Säule

Agilent / GC Kapillarsäulen

HP-PLOT AL2O3 M is the most polar aluminum oxide phase deactivated with proprietary deactivation. It is a good general use column for analysis of C1-C8 hydrocarbon isomers. It is excellent for resolving acetylene from butane and propylene from isobutene. Similar phases are, AB-PLOT Al2O3 M, BGB-PLOT Al2O3 M and AT-Alumina.

1,611.00 €

HP-PLOT Al2O3 KCI GC Säule mit 2 PT

Agilent / GC Kapillarsäulen

PLOT GC column, with two particle traps (front and rear)

1,617.00 €

HP-PLOT Al2O3 M GC Säule mit 2x PT

Agilent / GC Kapillarsäulen

PLOT GC column, with two particle traps (front and rear) HP-PLOT AL2O3 M is the most polar aluminum oxide phase deactivated with proprietary deactivation. It is a good general use column for analysis of C1-C8 hydrocarbon isomers. It is excellent for resolving acetylene from butane and propylene from isobutene.

1,877.00 €

19095P-K23LTM - HP-PLOT Al2O3 KCI GC Säule (LTM)

Agilent / GC Kapillarsäulen

LTM column module.

2,028.00 €

HP-PLOT Molesieve 5A GC Säule

Agilent / GC Kapillarsäulen

PLOT GC Columns. HP-PLOT Molesieve are offered in 0.53 and 0.32 mm id. For applications requiring resolution of argon and oxygen without expensive cryogenic cooling, select thick-film HP-PLOT Molesieve columns. The thin-film configurations are ideal for many applications, including routine air monitoring and analysis in less than 10 seconds. The thin-film column resolves argon and oxygen at subambient temperatures. Features • A PLOT column for the analysis of permanent gases • O2, N2, CO, and CH4 resolve in less than 5 minutes • Durable molecular sieve 5Å coating minimizes baseline spiking and damage to multiport valves • Select a thick film for Ar/O2 separation without cryogenic cooling • Select thin film HP-PLOT Molesieve columns for routine air monitoring applications • Replaces GS-Molesieve • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each GC column • Note: Molecular sieve columns absorb water, which over time results in changes in retention time. We use an advanced, proprietary deactivation process that allows for rapid regeneration. Fully saturated HP-PLOT Molesieve columns regenerate in 7 hours or less at 200 °C

1,180.00 €

HP-PLOT-Q GC Säule

Agilent / GC Kapillarsäulen

PLOT GC Columns. HP-PLOT Q is a bonded polystyrene-divinylbenzene (DVB) column with polarity between Porapak-Q and Porapak-N. It was specially developed for the separation of targeted nonpolar and polar compounds, including hydrocarbons (natural gas, refinery gas, ethylene, propylene, all C1–C3 isomers); CO2, methane, air/CO, and water; polar solvents (methanol, acetone, methylene chloride, alcohols, ketones, aldehydes, esters); and sulfur compounds (H2S, mercaptans, COS).

1,024.00 €

19095P-QO4LTM - HP-PLOT-Q, GC Säule (LTM)

Agilent / GC Kapillarsäulen

LTM column module. PLOT GC Columns. HP-PLOT Q is a bonded polystyrene-divinylbenzene (DVB) column with polarity between Porapak-Q and Porapak-N. It was specially developed for the separation of targeted nonpolar and polar compounds, including hydrocarbons (natural gas, refinery gas, ethylene, propylene, all C1–C3 isomers); CO2, methane, air/CO, and water; polar solvents (methanol, acetone, methylene chloride, alcohols, ketones, aldehydes, esters); and sulfur compounds (H2S, mercaptans, COS).

2,108.00 €

HP-PLOT-Q GC Säule mit 2x PT

Agilent / GC Kapillarsäulen

PLOT GC Columns with two particle traps (front and rear). HP-PLOT Q is a bonded polystyrene-divinylbenzene (DVB) column with polarity between Porapak-Q and Porapak-N. It was specially developed for the separation of targeted nonpolar and polar compounds, including hydrocarbons (natural gas, refinery gas, ethylene, propylene, all C1–C3 isomers); CO2, methane, air/CO, and water; polar solvents (methanol, acetone, methylene chloride, alcohols, ketones, aldehydes, esters); and sulfur compounds (H2S, mercaptans, COS).

706.00 €

VF-1701MS GC Säule +EZ-Vorsäule

Agilent / GC Kapillarsäulen

VF-1701ms 30mx0,25mmx0,25um +5m EZ-Guard. EZ-Guard columns combine an Agilent J&W VF GC column with a built-in guard column. The first 5 or 10 m section of the column (depending on the configuration) is not coated with stationary phase, but has been deactivated. Eliminating the column connection between the guard and analytical sections ensures 100% leak-free performance.

944.00 €

CP915192 - Lowox UltiMetal gepackte GC-Säule

Agilent / GC Kapillarsäulen

J&W GC packed column in UltiMetal tubing, length 0.33 ft (0.1 M), 1/16 in. OD, 1 mm OD, Lowox phase on Chromosorb 750 packing, mesh size 80/100

1,157.00 €

VF-WAXMS GC Säule

Agilent / GC Kapillarsäulen

Low Bleed GC/MS Columns: • Specially designed wax phase for accurate MS results with polar compounds • Operating temperature range of 20 to 250/260 °C • Improves signal-to-noise ratio for trace analysis • Ideal for GC/MS food, flavor, and fragrance applications, especially where trace analyses are required • Ultra low bleed provides increased sensitivity and extended column lifetime at higher temperatures • Improved performance with no change in the typical selectivity of PEG • 0.15 mm id columns available for high efficiency GC and GC/MS analyses • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column • Similar phases: SUPELCOWAX 10, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, Rtx-WAX, ZB-WAX, ZB-WAX plus

834.00 €

CP957754 - CP7170 auf 11,5-cm-Korb

Agilent / GC Kapillarsäulen

Catalog No. 7170 on 115 mm cage

1,361.00 €

CP958368 - CarboBOND UltiMetal

Agilent / GC Kapillarsäulen

CarboBOND UltiMetal 25m x 0,25mm x 10um

2,153.00 €

DB-17HT GC Säule

Agilent / GC Kapillarsäulen

High Temperature GC Columns. DB-17ht provides excellent performance for accurate extended temperature range analysis. These mid-polarity columns are solvent rinsable and feature a special high-temperature polyimide-coated fused silica tubing. Stable and efficient manufacturing, utilizing high-quality components and processes, results in improved resolution for the effective analysis of triglycerides and other high boilers over extended temperature limits of 40 to 340/365 °C. Features: • (50%-Phenyl)-methylpolysiloxane • Mid-polarity • Extended upper temperature limit of 365 °C • High temperature, polyimide-coated, fused silica tubing • Excellent peak shape and faster elution times for high boilers • Improved resolution for triglycerides • Ideal for confirmation analysis • Bonded, crosslinked, and solvent rinsable • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column • Similar phases: Rtx-65TG, BPX50

1,301.00 €

122-1831LTM - DB-17HT LTM GC Säule

Agilent / GC Kapillarsäulen

LTM column module. High Temperature GC Columns. DB-17ht provides excellent performance for accurate extended temperature range analysis. These mid-polarity columns are solvent rinsable and feature a special high-temperature polyimide-coated fused silica tubing. Stable and efficient manufacturing, utilizing high-quality components and processes, results in improved resolution for the effective analysis of triglycerides and other high boilers over extended temperature limits of 40 to 340/365 °C. Features: • (50%-Phenyl)-methylpolysiloxane • Mid-polarity • Extended upper temperature limit of 365 °C • High temperature, polyimide-coated, fused silica tubing • Excellent peak shape and faster elution times for high boilers • Improved resolution for triglycerides • Ideal for confirmation analysis • Bonded, crosslinked, and solvent rinsable • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column • Similar phases: Rtx-65TG, BPX50

1,935.00 €

DB-200 GC Säule

Agilent / GC Kapillarsäulen

Standard Polysiloxane GC Columns. DB-200 is a (35% trifluoropropyl)-methylpolysiloxane column. This mid-polarity column is ideal for difficult-to-separate positional isomers. It has unique interactions with compounds containing nitro, halogen, and carbonyl groups. Features: • (35% Trifluoropropyl)-methylpolysiloxane • Temperature limits of 300 °C isothermal and 320 °C programmed • Mid polarity, more polar than DB-1701 or DB-17 • Ideal for difficult-to-separate positional isomers • Unique interactions with compounds containing nitro, halogen, and carbonyl groups • Low ECD bleed • Unique selectivity • Close equivalent to USP phase G6 • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column

738.00 €

122-2032LTM - DB-200 LTM GC Säule

Agilent / GC Kapillarsäulen

LTM column module. Standard Polysiloxane GC Columns. DB-200 is a (35% trifluoropropyl)-methylpolysiloxane column. This mid-polarity column is ideal for difficult-to-separate positional isomers. It has unique interactions with compounds containing nitro, halogen, and carbonyl groups. Features: • (35% Trifluoropropyl)-methylpolysiloxane • Temperature limits of 300 °C isothermal and 320 °C programmed • Mid polarity, more polar than DB-1701 or DB-17 • Ideal for difficult-to-separate positional isomers • Unique interactions with compounds containing nitro, halogen, and carbonyl groups • Low ECD bleed • Unique selectivity • Close equivalent to USP phase G6 • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column

1,854.00 €

DB-225 GC Säule

Agilent / GC Kapillarsäulen

DB-225 is crosslinked and solvent rinsable and is fully operational between temperature limits of 40 and 220/240 °C. These columns are excellent for effective separations of cis- and trans-fatty acid methyl esters. • (50%-Cyanopropylphenyl)-dimethylpolysiloxane • Mid/high polarity • Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) • Bonded, crosslinked, and solvent rinsable • Exact replacement of HP-225 • Close equivalent to USP Phase G7 • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column • Similar phases: SP-2330, Rtx-225, BP-225, OV-225, 007-225, AT-225

873.00 €

122-2232LTM - DB-225 LTM GC Säule

Agilent / GC Kapillarsäulen

LTM column module. DB-225 is crosslinked and solvent rinsable and is fully operational between temperature limits of 40 and 220/240 °C. These columns are excellent for effective separations of cis- and trans-fatty acid methyl esters. • (50%-Cyanopropylphenyl)-dimethylpolysiloxane • Mid/high polarity • Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) • Bonded, crosslinked, and solvent rinsable • Exact replacement of HP-225 • Close equivalent to USP Phase G7 • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column • Similar phases: SP-2330, Rtx-225, BP-225, OV-225, 007-225, AT-225

1,854.00 €

DB-23 GC Säule

Agilent / GC Kapillarsäulen

Standard Polysiloxane GC Columns DB-23 is specifically designed for the high-quality separation of fatty acid methyl esters (FAMEs). It is bonded, crosslinked, and solvent rinsable, and is a close equivalent to USP phase G5 and G48. This column has excellent resolution and a wide operating temperature range, and is well suited for procedures using cis- and trans- FAME isomers. Features: • (50%-Cyanopropyl)-methylpolysiloxane • High polarity, replaces HP-23 • Designed for separation of fatty acid methyl esters (FAMEs) • Excellent resolution for cis- and trans-FAME isomers • Close equivalent to USP phase G5 and G48 • Bonded, crosslinked, and solvent rinsable • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column

879.00 €

MONTHLY TOP PRODUCTS

Contact form

You have any questions on our shop or to one of our products?

Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.

Catalog request

You have any questions on our shop or to one of our products?

Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.

Are you a company or a private?