Thermo Scientific™ TraceGOLD™ TG-5MT Metal GC Columns provide greater stability and inertness at higher temperatures and when working with very active compounds. Offers greater robustness under increased stress. • Can be used at elevated temperatures without risk of bleeding or damage • Excellent inertia when working with highly active compounds • Robust under load
Thermo Scientific™ TraceGOLD TG-5SilMS GC Columns incorporate phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation. • Low polarity, silarylene phase with selectivity comparable to 5% diphenyl/95% dimethyl polysiloxane • Designed for low bleed and outstanding inertness • Similar to DB-5MS, VF-5ms, CP-Sil 8 Low-Bleed/MS, Rxi-5Sil MS, BPX5, ZB-5ms, Optima-5MS, SLB-5 Recommended for: • GC/MS applications using ion-trap systems • Polycyclic aromatics • Hydrocarbons including chlorinated hydrocarbons • Phthalates • Phenols • Amines • Organophosphates
TG-PEST5MS GC Column 20m x 0.18mmx0.2µm
GC Column TraceGOLD TG-1HT, 0.1 µm, 0.32 mm x 15 m
Perform fast analysis of multi-class contaminants including pesticides, PCB, PAHs, and PBDE with Thermo Scientific™ TraceGOLD™ TG-Contaminants GC columns. These highly inert capillary columns combine thermal stability with a unique selectivity to ensure excellent chromatographic peak shapes and sensitivity. Key Benefits • Perform multi-class contaminant analysis on one column • Optimized efficiency and selectivity for high throughput • Robust with a maximum temperature of 360°C
TG-FAME GC Column 50m x 025mm x 020µm
Thermo Scientific™ TraceGOLD™ TG-5SILMS Guard GC Columns with SafeGuard offer the benefit of an integrated SafeGuard for extended column lifetime. Using a guard column with a TraceGOLD TG-5SILMS GC column will lead to greater consistency in results over a longer period of time. • With integrated SafeGUARD • Available in a range of phases Spcifications: • Low polarity, silarylene phase with selectivity comparable to 5% diphenyl/95% dimethyl polysiloxane • Designed for low bleed and outstanding inertness • Similar to DB-5MS, VF-5ms, CP-Sil 8 Low-Bleed/MS, Rxi-5Sil MS, BPX5, ZB-5ms, Optima-5MS, SLB-5 Recommended for: • GC/MS applications using ion-trap systems • Polycyclic aromatics • Hydrocarbons including chlorinated hydrocarbons • Phthalates • Phenols • Amines • Organophosphates
TG-Packed Column PP-Q 80/100 2M, 2.0 mm ID 1/8IN OD NICKEL GEN CONFIG NOC KIT-D
TG-Packed Column HS-Q 80/100 10.0FT 2.0 mm ID 1/8ID OD SILCO HP STD HP CPMFIG OC INV: 2.0IN OUTV:1.5IN NO KIT
TG-Micropacked Column TCEP-D4815 0.56 m, 0.75 mm ID
TG-Packed Column 30.0% DC-200/500 CHR-PNAW 80/100 0.4 m 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC NO KIT
TG-Packed Column 30.0% DC-200/500 CHR-PNAW 80/100 7.3 m 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC NO KIT
TG-Packed Column MS-5A 80/100 8m 2.0 mm ID 1/8IN OD SILCO GEN CONFIG NOC KIT-D
TG-Packed Column PP-N 80/100 1.83m 2.0 mm ID 1/8IN OD SILCO HP STD HP CONFIGG OC INV:2.0IN OUTV:1.5IN NO KIT
TG-Packed Column MS-5A 60/80 1.83m 2.0 mm ID 1/8IN OD SILCO HP STD HP CONFIG OC INV:2.0IN OUTV:1.5IN NO KIT
Thermo Scientific™ TraceGOLD TG-5MS AMINE GC Column enables analysis of ppm levels of amines without column priming. • Low polarity phase, 5% diphenyl/95% dimethyl polysiloxane • Tubing surface is chemically altered to reduce tailing of active basic compounds • Also allows analysis of neutral or weakly acidic compounds (e.g., phenols) and compounds susceptible to hydrogen bonding • Low bleed at maximum operating temperature Recommended for: • Amines and other basic compounds, including alkylamines, diamines, triamines, ehtanolamines • Nitrogen-containing heterocyclics
Specifications: • Low polarity phase, 5% diphenyl/95% dimethyl polysiloxane • Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity • Exceptional inertness ideal for analysis of active compounds • Equivalent to USP G27 phase • Similar to Rxi™-5ms, DB-5, HP-5, HP-5ms, Ultra-2, SPB-5, Equity-5, CP-Sil 8 Recommended for: • Semivolatiles • Phenols • Amines • Residual solvents and solvent impurities • Drugs of abuse • Pesticides • PCB cogeners • Aroclor mixes
TG-Packed Column 30.0 DC-200/500 CHR-PAW 60/80 2.0 ft 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC KIT-B
TG-Packed Column MS-13X 45/60 4.0 ft. 2.0 mm ID 1/8IN OD SS GEN CONFIG NOC KIT-B
TG-Packed Column 30.0% DC-200/500 CHR-PAW 60/80 35.0 ft 2.0 mm ID 1/8IN OD KIT-B
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.