5975T LTM column module. LTM column module asembly for Agilent 5975T; includes LTM column toroid, LTM transferlines, cooling fan, cover, ultimate unions and sheetmetal housing.
Intuvo GC column module (compatible only with the Intuvo 9000 GC System)
Intuvo GC column module (compatible only with the Intuvo 9000 GC System)
Intuvo GC column module (compatible only with the Intuvo 9000 GC System)
Intuvo GC column module (compatible only with the Intuvo 9000 GC System)
Intuvo Petroleum Specialty Columns For challenging petrochemical and petroleum analysis applications with the Intuvo 9000 GC system.
Standard Polysiloxane GC Columns. DB-1701 is a low/mid-polarity (14% cyanopropyl-phenyl)-methylpolysiloxane column. It is ideal for the analysis of pesticides, herbicides, trimethylsilyl (TMS) derivatives of sugars and related substances, and aroclors. The column is bonded, crosslinked, and solvent rinsable and is available with DuraGuard (the GC column with a built-in guard column). Features: • (14%-Cyanopropyl-phenyl)-methylpolysiloxane • Solvent rinsable with low/mid polarity • Bonded and crosslinked • Exact replacement of HP-1301 and HP-1701 • Available with DuraGuard (the GC column with a built-in guard column) • Tested against the strictest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column • Similar phases: SPB-1701, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-1701
Intuvo GC column module (compatible only with the Intuvo 9000 GC System)
Ultra Inert GC Columns. DB-WAX Ultra Inert (UI) represents the ultimate performance of PEG stationary phase inertness, providing symmetric peak shape and improved response for challenging polar compounds. All DB-WAX UI columns are individually tested with an Ultra Inert Wax test probe mixture according to the strictest industry QC standards to ensure consistent column-to-column inertness performance for challenging active analytes such as free fatty acids, alcohols, diols, and aldehydes, with minimal compound adsorption or degradation. Since it offers the same selectivity as Agilent J&W DB-WAX, upgrading to Ultra Inert performance is easy, with minimal validation required – there's no need to recreate or modify existing compound libraries that are based on DB-WAX selectivity. Features: • Improved peakshape for challenging polar compounds with DB-WAX Ultra Inert • Reliable column-to-column inertness performance • Bonded polyethylene glycol (PEG) selectivity equivalent to DB-WAX • No method revalidation needed • High polarity • Equivalent to USP G16 • Excellent performance for acidic compounds, including free fatty acids – no need for FFAP type column • Bonded and crosslinked phase is solvent rinseable and tolerates aqueous injections
Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, HP-Innowax, Rtx-WAX, ZB-WAX Temperature Limits: 20 to 250/260 °C
LTM column toroid assembly for Agilent 5975T
• Polyethylene glycol (PEG) • Extended Temperature Range (etr) • High polarity • Excellent column-to-column repeatability • Bonded and cross-linked • Solvent rinsable • Equivalent to USP Phase G16
Application Specific GC Columns. CP-Sil 88 contains a highly substituted and stabilized cyanopropyl phase. It has the highest polarity and is non-chemically bonded. The extremely high polarity of this column offers maximum resolution in separations where the boiling point and polarity of the analytes are nearly equal, for example, in the separation of positional and geometric isomers.
PLOT GC Columns. CP-Molsieve 5Å is a molecular-sieve-coated PLOT capillary column specially suited for high-resolution separation of permanent gases. Analysis times are reduced by up to 75% compared to packed columns. Baseline separation of Ar/O2 is achieved at ambient temperature. The column’s thin-layer dimensions produce fast elution of CO with symmetrical peaks.
PLOT GC Columns: PoraPLOT Q is recommended for column switching systems that analyze polar and apolar volatile compounds. Water elutes as a sharp and quantifiable peak, making retention times of target compounds repeatable, as they are not influenced by water in the sample.
CP-Al2O3/Na2SO4 is an aluminum oxide PLOT column that offers high selectivity for separating ppm levels of C1–C5 hydrocarbons in a main stream of C1–C5 hydrocarbons. The Na2SO4 deactivation salt provides a polar Al2O3 surface, so that unsaturated compounds such as ethylene and acetylene are retained longer. These columns analyze more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, CP-Al2O3/Na2SO4 provides increased selectivity and allows all C1–C5 hydrocarbon isomers to be separated. These columns operate without the need for sub-ambient cooling. Similar phases: Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT, Rt-Alumina BOND/Na2SO4, MXT-AluminaBOND/Na2SO4, Alumina sulfate PLOT
WAX GC Columns: • Polyethylene glycol (PEG) phase • High polarity, suitable for a broad range of separations • Excellent column-to-column inertness reproducibility • Sharp and symmetrical peak shape performance for active polar compounds • Bonded, crosslinked, and solvent rinsable • Wider temperature range than non-bonded polyethylene glycols • High resolution of low boiling point analytes • Excellent temperature stability for a variety of EPA and ASTM methods • QC tested with highly demanding test probes • Performance Summary shipped with each column • UltiMetal column recommended for working in rugged environments with process or portable instruments • Similar phases: Supelcowax 10, Stabilwax, BP-20, 007-CW, Rtx-WAX, ZB-WAX, ZB-WAXPlus
PLOT GC Columns: PoraBOND Q is the long-term solution for analyzing volatile solvents and hydrocarbons. It is the most stable column of its kind and withstands repeated water injections. The porous polymer is very pure and has virtually no catalytic activity. This means that PoraBOND Q can be used up to 320 °C without decomposition. Features • Bonded PLOT column for more reliable results for analysis of volatile solvents and hydrocarbons • Extended analysis offers broad application range • Temprerature limits of 300 isothermal and 320 °C programmed • Engineered for high stability, withstands repeated water injections • Proprietary manufacturing technique results in very pure porous polymer with virtually no catalytic activity, allowing operation to 320 °C without decomposition • Bonding technology results in greatly reduced particle shedding, reduces the needs for particle traps • Tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency • Performance Summary shipped with each column
PLOT PT columns have an integral particle trap at each end, eliminating the need to connect separate traps. Operation is more convenient, with no risk of leaks. Integrated particle-trapping technology on both column ends reduces downtime and allows the use of GC/MS for detailed qualitative and quantitative analysis.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.