Environmental Spike Mix, 100ml - Dangerous Good
Environmental calibration standard, 1000 ppm each of Fe, K, CA, Na, Mg, 10 ppm each of Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, Zn, Th, U in 10% HNO3, 100 mL. Dangerous goods
Neutral density attenuator 1.5 Abs. 1/pk
Calibrated solution validation test kit. Solution validation test kit of 12 sealed cells for testing performance of a UV spectrophotometer (wavelength accuracy, photometric accuracy, stray light, etc). Includes potassium dichromate 40 mg/L, 60 mg/L, 120 mg/L, 600 mg/L plus perchloric acid blank for photometric accuracy tests, holmium perchlorate 4 % in 10 % perchloric acid for wavelength accuracy tests, potassium chloride solution 12 g/L, sodium nitrite solution 50 g/L, sodium iodide - 1 % solution plus water blank for stray light tests, 0.02 % toluene in hexane plus a hexane blank for resolution tests. Each solution is sealed in a quartz cuvette. A certificate of traceability and performance is included for each solution.
ICP-MS Calibration Standards.
6020 Interference Check Solution A. For use with ICP-MS systems, 100 ml bottle, in 5% HNO3 with trace amounts of HF
6020 Interference Check Solution B. For use with ICP-MS systems. Contains: 20 ppm of Cr, Co, Cu, Mn, Ni and V, 10 ppm of As, Cd, Se, and Zn, 5 ppm of Ag. Bottle of 100ml, Matrix = 5% HNO3
ICP-MS Stock Tuning Solution; Li, Y, Ce, Tl and Co; 100 mL, 10 mg/L; matrix 2% HNO3
ICP-MS tuning solution; Li, Mg, Y, Ce, Tl and Co; 100 mL, 10 mg/L; matrix 2% HNO3
ICP-MS checkout solution, required by Agilent installation engineer to validate Agilent 7700 performance on site. Includes tuning solution, dual mode (1), dual mode (2), wash solution, water blank solution
ICP-MS Checkout Solution for 7500s. Contains tuning solution, dual mode (1), dual mode (2), abundance sensitivity (1), abundance sensitivity (2), detection limit solution, high sensitivity tune, wash, and water blank solutions
ICP-MS Checkout Soln for 7500a and 7500i
Quality control standard, QCSTD-27, 100 mL. Contains: Al, Sb, As, Ba, Be, B, Cd, Ca, Cr, Co, Cu, Fe, Pb, Mg, Mn, Mo, Ni, K, Se, Si, Ag, Sr, Na, Tl, Ti, V & Zn at 100 mg/L
Calibration mix 1 for AA and ICP-OES; 125 mL, contains 100 mg/L Sb, Mo, Sn and Tl in 2 % HNO3 + 0.5 % HF
Calibration mix 2 for AA and ICP-OES; 125 mL, contains 100 mg/L Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Se, Tl, Th, U, V and Zn in 5 % HNO3
Calibration mix majors for AA and ICP-OES; 125 mL, contains 500 mg/L Ca, Fe, K, Mg and Na in 5 % HNO3
Calibration mix 3, organic for AA and ICP-OES; 100 mL, contains 500 mg/kg Ag, Al, B, Ba, Ca, Cd, Cr, Cu, Fe, Mg, Mn, Mo, Na, Ni, P, Pb, Si, Sn, Ti, V and Zn in mineral oil
ICP-OES wavelength calibration solution; 500 mL, contains 50 mg/L Al, As, Ba, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Sr, Zn and 500 mg/L K in 5 % HNO3
ICP-OES wavelength calibration solution; 500 mL, contains 5 mg/L Al, As, Ba, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Sr, Zn and 50 mg/L K in 5 % HNO3
Calibration blank solution 5% HNO3 for ICP-OES, MP-AES, and AA, Certified Reference Material, 500 mL