Oxygen measurement

Your filters:
19 Found products
Products per page

59906816 - O²-Simulator 82

Mettler-Toledo GmbH / Sauerstoffmessung

The O2 simulator 82 is used to test the functional integrity of the O2 transmitter and the connecting cable. It simulates a METTER TOLEDO O2 sensor. Each O2 simulator 82 is tested by METTLER TOLEDO prior to delivery. Important notes – Maintenance-free; no batteries required. – The O2 simulator is not yet approved for use in explosion-hazard rooms. – Do not open the O2 simulator. Product performance The O2 simulator 82 is connected to the transmitter with a cable instead of the METTLER TOLEDO O2 sensor

883.75 €

Sauerstoffmessgerät Seven2Go™ S4

Mettler-Toledo GmbH / Sauerstoffmessung

Portable routine model for dissolved oxygen measurement. • New, intuitive menu structure with fast and easy T-Pad navigation • Robust design with IP67 protection for use in harsh and demanding environments • Intelligent Sensor Management (ISM®) functionality reduces the risk of errors • Up to 2 calibration points and a choice of 2 predefined oxygen standards • Automatic, manual and time dependant endpoint recording • Data memory storage for 200 data points • Power requirements: 4 x 1.5 V AA or 1.3 V NiMH accumulators Supplied with: S4-Meter: Includes instrument, electrode clip, operating instructions, quick guide, test certificate, declaration of conformity, batteries S4-Standard kit: As S4-Meter, but also with InLab 605-ISM and zero oxygen tablets S4-Field kit: As S4-Standard kit, but also with bottles for calibration, uGo™ carrying case Specifications Measuring range (O2 Saturation): 0.1 ... 600.0% Resolution: 0.1 Accuracy: ±10% Measuring range (Temperature): Accuracy: 0.0 ... 60.0°C Resolution: 0.1°C Accuracy: ±0.2°C Measuring range (O2concentration): 0.01 ... 99.99 mg/l (ppm) Accuracy (display): ±0.2 mg/l in range 0 ... 15 mg/l / ±10% in range 15 ... 60 mg/l Measuring range (Pressure): 500 ... 1100 mbar Resolution: 1 Accuracy: ±2% Dimensions (W x D x H): 222 x 70 x 35 mm

650.00 €

59906445 - O²-Polarisations-Modul OPM 131

Mettler-Toledo GmbH / Sauerstoffmessung

The O2 polarization module supplies the polarization voltage of 675 mV and is switched on automatically when connec ted to the sensor. The battery of the module has a lifetime of more than 5 years. The voltage can be measured between pins A and C and should be greater than 2.5 Volts. If the voltage drops below this level, the polari zation module should be returned to your supplier for a battery exchange. Operating environment: – For indoor use only – Max. relative humidity: 80% – Temperature range: 5...40°C – Never sterilize the polarization module

897.40 €

O²-Sensor InPro6800

Mettler-Toledo GmbH / Sauerstoffmessung

Oxygen Probe for Sterile Conditions. • The InPro 6800 dissolved oxygen sensor with 12 mm diameter body provides maximum accuracy and ultimate cleanability. • A sensor for hygienic applications • The sensor has been developed to comply fully with the EHEDG and FDA flat-surface recommendations for extremely high-level hygienic applications. • The 316L stainless steel construction allows for CIP, steam sterilization or autoclaving in place. The sensor finish eliminates process contamination. • The InPro 6800 DO sensor is easy to integrate into your process. Its watertight VP connector (IP68) helps ensure reliable measurements. • Ingold's PTFE/silicone membranes have been designed with an internal steel mesh that makes the membrane more rugged and dramatically increases membrane life. Specifications: Measurement parameters: oxygen Measuring technology: Amperometric/polarographic Measuring temperature range: 0°C – 80°C Accuracy: ± (1% of reading +6ppb) Response time: T98 = < 90 s at 25 °C (77 °F) (air on N2) IP protection class: IP68 Primary media/application: pharmaceuticals/life science production ISM (digital) or Analogue: Analogue Anti-bubble design: no Wetted metallic material: 316L stainless steel Surface roughness of the wetted parts (2): N5/Ra16 (Ra = 0.4 μm/16 μin) O-ring material: silicone Process connection: Ingold (25 mm) Membrane material in contact with media: PTFE Plug design: Straight Autoclavable/sterilizable: Yes Mechan. Temp. resistance: -5°C – 140°C Operating pressure (bar): 0.2 to 6 bar Pressure range during measurement. 0.2bar - 6bar Design pressure: 12 bar Analog integration: nA signal Cable connection: VP6 Hygiene/Biocompatibility Approvals: EHEDG/FDA/USP Class 6 Approvals for hazardous areas: FM (C US): IS / I, II, III / 1 / ABCDEFG/ T6 Ta=60 °C 53 800 002 Unit ATEX:/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb/Ex ia IIIC T69°C/T81°C/T109°C/T161°C Da/Db Certificates and Approvals: Quality Certificate, Material Certificate 3.1, Surface Finish Certificate, ATEX/IECEx/FM Certificate, FDA/USP Class VI Sensor signal in ambient air at 25 °C: 50 to 110 nA Detection limit: 6 ppb Measuring range: 0 to 100% O2 saturation Sterilizable/Autoclavable Yes Residual signal in oxygen-free media: <0.1% of the signal in ambient air Connection: VP (IP 68) Pg 13.5 ​

3,113.95 €

30298424 - O²-Elektrolyt Lösung Kaliumhydroxidlösung

Mettler-Toledo GmbH / Sauerstoffmessung

O²-electrolyte solution UN 1814, 8, III, (E) pack of 3x25 ml

114.10 €

MONTHLY TOP PRODUCTS

Contact form

You have any questions on our shop or to one of our products?

Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.

Catalog request

You have any questions on our shop or to one of our products?

Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.

Are you a company or a private?