Maintenance on site HCP according to Memmert maintenance plan (available on request) (travel costs are not included yet)
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances
Holder for water tank (2.5 litres) for mounting on the rear of the appliance. Standard equipment for size 750
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/410/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6
4 - 20 mA current loop interface (0 to +310 °C = 4 - 20 mA); Temperature controller, actual value
Climatic test chamber CTC265, 256 l, -42 °C to +190 °C without humidity, +10 °C to +95 °C with humidity, humidity adjustable from 10 98 % rh, adaptive, fuzzy-supported, multifunctional, digital PID microprocessor controller with auto-diagnostc system; 2 Pt100 sensors, USB interface incl. Celsius software for programming and documentation, printer interface, longtime documentation according to the GLP guidelines (ring memory as datalogger) of all relevant data, twin compressor, adjustable speed condenser fan and electronically controlled refrigerant injection; chlorine-free, ozone-neutral refrigerant R449A, stainless steel interior, hermetically welded, 3-layer high tech insulation, with 1 grid, heated stainless steel door, telescopic slide for 2 x 10 l tanks for destilled water as fresh water and 2 x 10 l as condensate collector, automatic water tank changer-over with alarm for continuous operation, over- and undertemperature protection; works calibration certificate at -30 °C and +160 °C; textured stainless steel exterior: 898 x 1730 x 1100 mm; stainless steel interior: 640 x 670 x 597 mm; voltage: 400 V, 3ph N, 50 Hz; max. electrical load: approx. 7000 W
4 - 20 mA current loop interface; Humidity controller, actual value (0 to 100 % rh = 4 - 20 mA) (requires option K7 or K6)
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet)
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge)
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.