QuEChERS

Ihre Auswahl:

730972.100 - CHROMABOND QuEChERS Mix III Clean-up (1,05 g), BIG Box

Macherey-Nagel GmbH & Co. KG / QuEChERS

CHROMABOND QuEChERS Mix III Diamino Clean-up-Mix BIG Box bestehend aus: - 900 mg MgSO4 - 150 mg CHROMABOND Diamino einzeln eingewogen in 15 mL Zentrifugenröhrchen (PP) mit Deckel (PE). Empfohlene Anwendung: Ananas, Aprikose, Birne, Brokkoli, Erdbeere, Forensische Anwendungen und Drogenproben bzw. Medikamente, Lebensmittelproben, Pestizide, Proben mit geringem Fettgehalt, Probenvorbereitung, QuEChERS, Spargel, Äpfel

215,00 €
Details zum Produkt

730973 - CHROMABOND QuEChERS Mix IV Clean-up (1,065 g)

Macherey-Nagel GmbH & Co. KG / QuEChERS

CHROMABOND QuEChERS Mix IV Diamino/Carbon Clean-up-Mix bestehend aus: - 900 mg MgSO4 - 150 mg CHROMABOND Diamino - 15 mg CHROMABOND Carbon einzeln eingewogen in 15 mL Zentrifugenröhrchen (PP) mit Deckel (PE). Empfohlene Anwendung: Forensische Anwendungen und Drogenproben bzw. Medikamente, Kaffee, Karotte, Kopfsalat, Lebensmittelproben, Pestizide, Proben mit mäßigem Gehalt an Chlorophyll und Carotinoiden (Pigmente), Probenvorbereitung, Tee.

134,00 €
Details zum Produkt

730974 - CHROMABOND QuEChERS Mix VI Clean-up (1,2 g)

Macherey-Nagel GmbH & Co. KG / QuEChERS

CHROMABOND QuEChERS Mix VI Diamino/C18 ec Clean-up-Mix bestehend aus: - 900 mg MgSO4 - 150 mg CHROMABOND Diamino - 150 mg CHROMABOND C18 ec einzeln eingewogen in 15 mL Zentrifugenröhrchen (PP) mit Deckel (PE). Empfohlene Anwendung: Avocado, Babynahrung, Boden, Forensische Anwendungen und Drogenproben bzw. Medikamente, Getreide, Huhn, Lebensmittelproben, Molkereiprodukte, Nüsse, Pestizide, Proben mit höherem Fettgehalt, Probenvorbereitung, QuEChERS, Rindfleisch, Schweinefleisch, Öle.

108,00 €
Details zum Produkt

730974.100 - CHROMABOND QuEChERS Mix VI Clean-up (1,2 g), BIG Box

Macherey-Nagel GmbH & Co. KG / QuEChERS

CHROMABOND QuEChERS Mix VI BIG Box Diamino/C18 ec Clean-up-Mix bestehend aus: - 900 mg MgSO4 - 150 mg CHROMABOND Diamino - 150 mg CHROMABOND C18 ec einzeln eingewogen in 15 mL Zentrifugenröhrchen (PP) mit Deckel (PE). Empfohlene Anwendung: Avocado, Babynahrung, Boden, Forensische Anwendungen und Drogenproben bzw. Medikamente, Getreide, Huhn, Lebensmittelproben, Molkereiprodukte, Nüsse, Pestizide, Proben mit höherem Fettgehalt, Probenvorbereitung, QuEChERS, Rindfleisch, Schweinefleisch, Öle.

215,00 €
Details zum Produkt

31964 - AOAC QuEChERS Triphenylphosphate Solution

Restek / QuEChERS

AOAC QuEChERS Triphenylphosphate Solution • Ready to use for generating test mixes, calibration standards, and spiking experiments. • Reliable standards produced according to specifications defined in AOAC Official Method 2007.01. • Cost-effective QuEChERS standards can be used without dilutions for greater lab efficiency.

55,00 €
Details zum Produkt

Q-sep QuEChERS dSPE Zentrifugenröhrchen

Restek / QuEChERS

Q-sep™ QuEChERS dSPE-Röhrchen zur Extraktreinigung • Gebrauchsfertige Röhrchen, keine Glaswaren erforderlich. • Vorgewogene, hochreine Sorbentien. • Unterstützung der ursprünglichen ungepufferten, AOAC (2007.01), europäischen (EN 15662) und Mini-Multiresidue-QuEChERS-Methoden. QuEChERS-Methoden sind schnell, einfach und kostengünstig, und Restek Q-sep™-Produkte machen QuEChERS-Verfahren noch einfacher. Alle Extraktionssalze, Sorbentien und Probenröhrchen sind enthalten – es sind keine speziellen Geräte oder Glaswaren erforderlich. Bereiten Sie Proben effizienter vor mit einer kompletten Reihe von QuEChERS-Verbrauchsmaterialien von Restek. • Verpackt in Folien-Unterpackungen mit 10 Stück für verbesserten Schutz und Lagerstabilität. Mehrere Sorbentien werden verwendet, um verschiedene Arten von Interferenzen zu extrahieren. MgSO4 entfernt überschüssiges Wasser PSA entfernt Zucker, Fettsäuren, organische Säuren und Anthocyanin-Pigmente C18 entfernt unpolare Störungen GCB entfernt Pigmente, Sterole und unpolare Störungen PSA – primäres und sekundäres Amin-Austauschmaterial GCB – graphitierter Ruß

139,00 €

33263 - QuEChERS Stock Solution PCB 153

Restek / QuEChERS

QuEChERS Single-Component Reference Standards • Ready to use for QuEChERS extractions—no dilutions necessary. • Support for GC and LC with MS, MS/MS, and selective detectors. Pesticide analysis is fast and simple using QuEChERS methods. Use these cost-effective QuEChERS standards for even greater lab efficiency. Standards are compatible with all major methods, including mini-multiresidue, AOAC, and European procedures. Save time with convenient mixes or make your own blend using our full line of single-component solutions.

49,00 €
Details zum Produkt

31152 - QuEChERS Performance Standards Kit

Restek / QuEChERS

QuEChERS Performance Standards Kit • Designed for use in all QuEChERS methods for pesticides in fruits and vegetables, including the original unbuffered method, AOAC 2007.01, and EN15662. • Kit contains organochlorine, organonitrogen, organophosphorus, and carbamate pesticides commonly used on fruits and vegetables. • Volatile, polar, active, base-sensitive, and nonvolatile compounds are included to allow comprehensive evaluation of QuEChERS extraction and cleanup efficiencies, and optimization of GC and LC instrumental conditions. • Ideal for initial method evaluations and ongoing method performance validations. • Analytes are divided into three ampuls based on compatibility for maximum stability and shelf life.* • Precise formulations improve data quality and operational efficiency, spend more time running samples and less time sourcing and preparing standards. • Quantitatively analyzed to confirm the composition and stability of each mixture. • Produced and tested in accordance with ISO Guide 34 and 17025 accreditation. *When combining compounds with different functionalities, chemical stability can be an issue. The analytes in this kit are separated into three mixes to ensure maximum long-term storage stability. For analysis, a fresh working standard should be prepared by combining the three kit mixes in a 1:1:1 ratio to prepare a 100 μg/mL working standard solution. Once blended, Restek does not recommend storing working standards or subsequent dilutions for future use. Contains 1 mL each of these mixtures. 31153: QuEChERS Performance Standard A 31154: QuEChERS Performance Standard B 31155: QuEChERS Performance Standard C Compounds: Cat.# 31153: QuEChERS Performance Standard A (16 components) Acephate (30560-19-1) Azinphos methyl (86-50-0) Chlorpyrifos (2921-88-2) Coumaphos (56-72-4) Diazinon (333-41-5) Dichlofluanid (1085-98-9) Dichlorvos (DDVP) (62-73-7) Dimethoate (60-51-5) Fenthion (55-38-9) Malathion (121-75-5) Methamidophos (10265-92-6) Mevinphos (7786-34-7) Omethoate (1113-02-6) Phosalone (2310-17-0) Pirimiphos methyl (29232-93-7) Propargite (2312-35-8) Cat.# 31154: QuEChERS Performance Standard B (7 components) gamma-BHC (Lindane) (58-89-9) Chlorothalonil (1897-45-6) 4,4′-DDT (50-29-3) Dicofol (Kelthane) (115-32-2) Endosulfan sulfate (1031-07-8) Endrin (72-20-8) 2-Phenylphenol (90-43-7) Cat.# 31155: QuEChERS Performance Standard C (17 components) Bifenthrin (82657-04-3) Captan (133-06-2) Carbaryl (sevin) (63-25-2) Cyprodinil (121552-61-2) Deltamethrin (52918-63-5) Fenhexamid (126833-17-8) Fenpropathrin (39515-41-8) Folpet (133-07-3) Imazalil (35554-44-0) Iprodione (36734-19-7) Metalaxyl (57837-19-1) Methiocarb (2032-65-7) Myclobutanil (88671-89-0) cis-Permethrin (61949-76-6 ) trans-Permethrin (61949-77-7) Thiabendazole (148-79-8) Vinclozolin (50471-44-8)

400,00 €
Details zum Produkt

31155 - QuEChERS Performance Standard C

Restek / QuEChERS

QuEChERS Performance Standard C (17 components) • Designed for use in all QuEChERS methods for pesticides in fruits and vegetables, including the original unbuffered method, AOAC 2007.01, and EN15662. • Ideal for initial method evaluations and ongoing method performance validations. • Optimized blend of chemically compatible analytes for maximum stability and shelf life. • Precise formulation improves data quality and operational efficiency, spend more time running samples and less time sourcing and preparing standards. • Quantitatively analyzed to confirm the composition and stability of each mixture. • Produced and tested in accordance with ISO Guide 34 and 17025 accreditation. Evaluating a new method? Try our full kit! QuEChERS performance standards kitare ideal for broad class work because they provide a wide range of commonly used organochlorine, organonitrogen, organophosphorus, and carbamate pesticides, while still keeping the total number of analytes to a reasonable level. Compounds: Bifenthrin (82657-04-3) Captan (133-06-2) Carbaryl (sevin) (63-25-2) Cyprodinil (121552-61-2) Deltamethrin (52918-63-5) Fenhexamid (126833-17-8) Fenpropathrin (39515-41-8) Folpet (133-07-3) Imazalil (35554-44-0) Iprodione (36734-19-7) Metalaxyl (57837-19-1) Methiocarb (2032-65-7) Myclobutanil (88671-89-0) cis-Permethrin (61949-76-6 ) trans-Permethrin (61949-77-7) Thiabendazole (148-79-8) Vinclozolin (50471-44-8)

174,00 €
Details zum Produkt

31963 - AOAC QuEChERS IS Solution

Restek / QuEChERS

AOAC QuEChERS IS Solution

196,00 €
Details zum Produkt

TOP-PRODUKTE DES MONATS

Kontakt-Formular

Sie haben Fragen zu unserem Shop oder einem unserer Produkte?

Bitte füllen Sie Ihre Kontaktdaten und Ihr Anliegen aus, wir melden uns umgehend mit allen gewünschten Informationen.

Katalogbestellung

Sie haben Fragen zu unserem Shop oder einem unserer Produkte?

Bitte füllen Sie Ihre Kontaktdaten und Ihr Anliegen aus, wir melden uns umgehend mit allen gewünschten Informationen.

Sind Sie Firmen- oder Privatkunde?