InfinityLab fitting for InfinityLab Stay Safe cap.
Ultra Clean Tubing Kit for 1290 Infinity II
Bottle head assembly for Solvent Reservoir.
Bottle head assembly, for 1260/1290 Infinity II Preperative LC system, includes bottle cap, tubing PTFE-ESD 2 m, fittings, and solvent inlet filter.
Bottle Head Assyembly for Prep System
Bottle head assembly for Agilent 1290 Infinity II LC SFC System.
Bottle head assembly, ultraclean tubing quality, long, recommended for MS applications
Bottle head assembly, 2.28 m extra long solvent tubing for the connection of the 1260 Infinity II Degasser (G7122A), when placed as lowest module in the stack
Bottle head assy For capillary and nano systems (with stainless steel solvent filter)
InfinityLab vent valve, PTFE, with time strip for InfinityLab Stay Safe cap
InfinityLab Stay Safe cap, GL45, 1 port, 1 InfinityLab vent valve, fitting
InfinityLab Stay Safe cap, GL45, 2 ports, 1 InfinityLab vent valve, 2 x fitting
InfinityLab Stay Safe cap, GL45, 3 ports, 1 InfinityLab vent valve, 3 x 3.2 mm od fitting
InfinityLab Stay Safe cap, GL45, 4 ports for waste, 2 x 3.2 mm od fitting, 2.3 mm od fitting, 1.6 mm od fitting
InfinityLab Stay Safe cap, GL38, 4 ports for waste, 2 x 3.2 mm od fitting, 2.3 mm od fitting, 1.6 mm od fitting. Recommended but not included is the 5043-1193 InfinityLab charcoal filter with time strip
InfinityLab Stay Safe cap, GL38, 1 port, 1 InfinityLab vent valve, 3.2 mm od fitting
Waste bin, for InfinityLab Flex Bench.
InfinityLab solvent bottle Pressure Plus for HPLC applications.
Flex Bench shelf assembly, with valve mounts 3/pk, for external valve drives allowing the attachment of up to three external valve drives underneath the shelf
InfinityLab identification silicone rings (2 x four colors)for solvent bottle.
Stickers, for InfinityLab solvent bottles.
InfinityLab Stay Safe cap starter kit, includes caps (5043-1217 3/pk and 5043-1218), venting valves with time strip (5043-1190 4/pk), fittings 3.2 mm 4/pk
Replacement hardware kit, for InfintiyLab Flex Bench, includes caster front/rear each, screws, nuts, bolts, tools.
Solvent line label clip set, set of clips for labeling the solvent supply lines (3.2 mm od), includes 1 each. Clip marked A, B,C, D, A1, A2, B1, B2
Bottle head tubing, ultra clean quality (recommended for MS application. Includes set of clips for marking the various channels, and solvent tubes, 2280 mm long, with premounted fittings on one side (1/4-28).
Bottle head tubing. Includes set of clips for marking the various channels, and solvent tubes, 2280 mm long, with premounted fittings on one side (1/4-28).
LC waste container, HDPE, 5 L, GL38, 23.5 × 6.4 × 37 cm
Screw plug, 5/16 in-24, POM, for prep LC caps
Solvent; bottle, clear, 2 L, 2 inlets
InfinityLab solvent bottle with cap for HPLC applications.
Fitting for 4.7 mm tubing, for prep LC Stay Safe caps, 2/pk
InfinityLab PFC-free HPLC Conversion Kit. For 1290 Infinity II systems with G7120A & G7167B. In trace-level PFAS analysis, the per- and polyfluorinated compounds (PFC)-free HPLC conversion kit is a complete solution for reducing PFAS background.
PFC-free Bottlehead Assembly. Includes PFC-free Stay Safe Cap & Vent Valve, PP tubing & Fitting, Stainless Steel Filter
PFC-free Sealwash Bottlehead Assembly. Includes PFC-free Stay Safe Cap & Vent Valve, Silicone tubing & PP Fitting, Stainless Steel Filter
Stay Safe starter kit and purging bottle, consisting of InfinityLab Stay Safe purging bottle (PN 5043-1339) and Stay Safe caps starter kit (PN 5043-1222)
Screw cap made of PPS for thread GL45 / PP for thread GLS 80, freely rotatable insert made of PP with 4 lateral connections (GL45) suitable for b.safe caps GL 45 and 3 central capillary connections (UNF 1/4 "). Rinsing the HPLC system without contamination or loss of solvents. It is very easy to use: Put the distributor on the rinsing bottle. Dismantle the b.safe caps from the eluent bottles and mount them on the connections of the rinsing bottle distributor. The passage on the distributor neck is sufficiently dimensioned so that the capillaries and filters mounted on the cap can be inserted into the rinsing bottle. With the GL45 flushing bottle distributor, the use of the smallest possible suction filter (max. Ø 14 mm) simplifies the insertion of the capillaries through the bottle neck. If a connection of the rinsing bottle distributor is not used, it can be closed with a screw cap GL45. The escape of harmful solvent vapors or contamination of the rinsing solution by ambient air are prevented by the b.safe caps with ventilation valve. In addition, the flushing bottle distributor can also be used directly for flushing the piston and needle seat. To do this, simply connect the desired capillaries and a ventilation valve to the centric capillary connections with b.safe fittings.
HPLC sets for removal of up to four bottles with GL 45 thread, consisting of b.safe caps GL 45, PFA fittings for capillaries with an outer diameter of 3.2 mm, blind fittings made of PFA to close unneeded connections, and ventilation valve with change indicator. Scope of delivery Starter Box A 3 x b.safe Cap GL 45 with 1 capillary connection 1 x b.safe Cap GL 45 with 2 capillary connections 4 x ventilation valve with change display 5 x fitting for hose outer Ø 3.2 mm (yellow) 1 x blind fitting (milky white) Scope of delivery starter box B 4 x b.safe Cap GL 45 with 2 capillary connections 4 x ventilation valves with change display 8 x fitting for hose outer Ø 3.2 mm (yellow) 4 x blind fitting (milky white) Scope of delivery Starter Box C 4 x b.safe Cap GL 45 with 3 capillary connections 4 x ventilation valves with change display 12 x fitting for hose outer Ø 3.2 mm (yellow) 8 x blind fittings (PFA-milky-white). Application Perfectly coordinated system for withdrawing eluents. With the b.safe fittings made of PFA, hoses can be inserted down to the bottom of the bottle, the conical sealing cone clamps the hose and reliably seals the connection. The b.safe ventilation valve is specially adapted to the volume flows in the HPLC. The integrated non-return valve prevents the evaporation of solvents and allows ambient air to flow into the bottle when there is negative pressure. The upstream membrane made of porous PTFE effectively holds back dirt particles and other impurities from the outside. The 6-month downtime can be easily monitored with the replacement display: Simply trigger it at the push of a button and replace the valve when the display is completely red or document the replacement date by hand and clip the display onto the valve.
Valve body made of PP with connection (thread UNF 1/4“ 28G) suitable for b.safe Caps. Lid with aeration opening and Luerlock connector, integrated non-return valve with upstream porous PTFE membrane (1 μm), including clip-on service life indicator. Chemical resistance: ++ very good. Applications For extraction of eluents. The b.safe Air Valve is especially adapted to the flow rate in HPLC. The integrated non-return valve avoids evaporation of solvents and lets flow ambient air into the bottle in case of vacuum. The upstream porous PTFE membrane restrains pollutant particles and other contaminations from outside. The 6 months service life of the Air Valve can be easily monitored through either activating the display on the service life indicator and exchanging the valve in case of completely red colouring or documentation of the exchange date by hand and clip on the service life indicator at the valve.
Screw cap made of PE for thread B83, freely rotatable insert made of PTFE. With PFA fittings for capillaries with an outer diameter of 3.2 mm (thread UNF 1/4 “), blind fittings made of PFA to close unneeded connections and a ventilation valve with change indicator. Perfectly coordinated system for withdrawing eluents. With the b.safe fittings made of PFA, hoses can be inserted down to the bottom of the bottle, the conical sealing cone clamps the hose and reliably seals the connection. The b.safe ventilation valve is specially adapted to the volume flows in the HPLC. The integrated non-return valve prevents the evaporation of solvents and allows ambient air to flow into the bottle when there is negative pressure. The upstream membrane made of porous PTFE effectively holds back dirt particles and other impurities from the outside. The 6-month downtime can be easily monitored with the replacement display: Simply trigger it at the push of a button and replace the valve when the display is completely red or document the replacement date by hand and clip the display onto the valve.
Screw cap made of PPS for thread GL45, freely rotatable insert made of PTFE. With PFA fittings for capillaries with an outer diameter of 3.2 mm (thread UNF 1/4 "), PTFE fittings preparative for tubing with an outer diameter of 6.35 mm (thread NPT 1/8"), blind fittings made of PTFE for closing unused connections and a ventilation valve with change indicator. Especially for the needs of preparative HPLC. At the hose connection, preparative hoses with an outer diameter of 4 mm to 6.35 mm can be inserted to the bottom of the bottle with b.safe fittings, the conical sealing cone clamps the hose and reliably seals the connection. The b.safe ventilation valve is specially adapted to the volume flows in the HPLC. The integrated non-return valve prevents the evaporation of solvents and allows ambient air to flow into the bottle when there is negative pressure. The upstream membrane made of porous PTFE effectively retains dirt particles and other contaminants from the outside. The 6-month downtime can be easily monitored with the replacement display: Simply trigger it at the push of a button and replace the valve when the display is completely red or document the replacement date by hand and clip the display onto the valve.
Screw cap made of PPS for thread GL45, freely rotatable insert made of PTFE. With PFA fittings for capillaries with an outer diameter of 3.2 mm (thread UNF 1/4 ") and a ventilation valve with change indicator. All capillary connections with integrated shut-off valve, connection to the bottom of the bottle via an additional capillary connection on the underside of the lid. Perfectly coordinated system for withdrawing eluents. With the b.safe fittings made of PFA, hoses can be connected to the capillary connections, the conical sealing cone clamps the hose and reliably seals the connection. The additional capillary connections on the underside of the lid allow hoses to be extended to the bottom of the bottle. The taps can be used to simply prevent dripping from connected lines when changing bottles. In addition, connections that are not required can be closed. The b.safe ventilation valve is specially adapted to the volume flows in the HPLC. The integrated non-return valve prevents the evaporation of solvents and allows ambient air to flow into the bottle when there is negative pressure. The upstream membrane made of porous PTFE effectively retains dirt particles and other contaminants from the outside. The 6-month downtime can be easily monitored with the replacement display: Simply trigger it at the push of a button and replace the valve when the display is completely red or document the replacement date by hand and clip the display onto the valve.
Screw cap made of PPS for thread GL28, freely rotatable insert made of PTFE. With PFA fittings for capillaries with an outer diameter of 3.2 mm (thread UNF 1/4 “), blind fittings made of PFA to close unneeded connections and a ventilation valve with change indicator. Perfectly coordinated system for withdrawing eluents. With the b.safe fittings made of PFA, hoses can be inserted down to the bottom of the bottle, the conical sealing cone clamps the hose and reliably seals the connection. The b.safe ventilation valve is specially adapted to the volume flows in the HPLC. The integrated non-return valve prevents the evaporation of solvents and allows ambient air to flow into the bottle when there is negative pressure. The upstream membrane made of porous PTFE effectively retains dirt particles and other contaminants from the outside. The 6-month downtime can be easily monitored with the replacement display: Simply trigger it at the push of a button and replace the valve when the display is completely red or document the replacement date by hand and clip the display onto the valve.
Screw cap made of PPS for thread S40, freely rotatable insert made of PTFE. With PFA fittings for capillaries with an outer diameter of 3.2 mm (thread UNF 1/4 “) and a ventilation valve with change indicator. All capillary connections with an integrated shut-off valve, connection to the bottom of the bottle via an additional capillary connection on the underside of the lid. Perfectly coordinated system for withdrawing eluents. With the b.safe fittings made of PFA, hoses can be connected to the capillary connections, the conical sealing cone clamps the hose and reliably seals the connection. The additional capillary connections on the underside of the lid allow hoses to be extended to the bottom of the bottle. The taps can be used to simply prevent dripping from connected lines when changing bottles. In addition, connections that are not required can be closed. The b.safe ventilation valve is specially adapted to the volume flows in the HPLC. The integrated non-return valve prevents the evaporation of solvents and allows ambient air to flow into the bottle when there is negative pressure. The upstream membrane made of porous PTFE effectively retains dirt particles and other contaminants from the outside. The 6-month downtime can be easily monitored with the replacement display: Simply trigger it at the push of a button and replace the valve when the display is completely red or document the replacement date by hand and clip the display onto the valve.
Screw cap made of PPS for thread GL45, flat, freely rotatable insert made of PTFE with threaded connections on the side at an angle of 90 ° to the bottle thread. With PFA fittings for capillaries with an outer diameter of 3.2 mm, blind fittings made of PFA to close off unneeded connections and a ventilation valve with change indicator. Particularly recommended when space is limited in height. Perfectly coordinated system for withdrawing eluents. With the b.safe fittings made of PFA, hoses can be inserted down to the bottom of the bottle, the conical sealing cone clamps the hose and reliably seals the connection. The b.safe ventilation valve is specially adapted to the volume flows in the HPLC. The integrated non-return valve prevents the evaporation of solvents and allows ambient air to flow into the bottle when there is negative pressure. The upstream membrane made of porous PTFE effectively retains dirt particles and other contaminants from the outside. The 6-month downtime can be easily monitored with the replacement display: Simply trigger it at the push of a button and replace the valve when the display is completely red or document the replacement date by hand and clip the display onto the valve.
Screw cap made of PP for thread GLS80, freely rotatable insert made of PTFE. With PFA fittings for capillaries with an outer diameter of 3.2 mm (thread UNF 1/4 “), blind fittings made of PFA to close unneeded connections and a ventilation valve with change indicator. Perfectly coordinated system for withdrawing eluents. With the b.safe fittings made of PFA, hoses can be inserted down to the bottom of the bottle, the conical sealing cone clamps the hose and reliably seals the connection. The b.safe ventilation valve is specially adapted to the volume flows in the HPLC. The integrated non-return valve prevents the evaporation of solvents and allows ambient air to flow into the bottle when there is negative pressure. The upstream membrane made of porous PTFE effectively retains dirt particles and other contaminants from the outside. The 6-month downtime can be easily monitored with the replacement display: Simply trigger it at the push of a button and replace the valve when the display is completely red or document the replacement date by hand and clip the display onto the valve.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.