Captiva pierceable 96-well collection plate cover, 10/pk
DuoSeal 96 96-well plate seals, 10/pk
• Standard SPE format • Ideal for LC/MS samples • Avoid sample transfer problems • Non-Drip (ND) 3 mL cartridges resist flow until vacuum is applied • Effectively remove phospholipids from biological samples with Captiva NDLipids
• Standard SPE format • Ideal for LC/MS samples • Avoid sample transfer problems • Non-Drip (ND) 3 mL cartridges resist flow until vacuum is applied • Effectively remove phospholipids from biological samples with Captiva NDLipids
• Standard SPE format • Ideal for LC/MS samples • Avoid sample transfer problems • Non-Drip (ND) 3 mL cartridges resist flow until vacuum is applied • Effectively remove phospholipids from biological samples with Captiva NDLipids
• Protect HPLC columns from clogging to reduce instrument downtime • Clean and clear filtrates offer improved sensitivity • High analyte recovery with simple robust methods allows faster method development
Captive ND Lipids 96-well bulk
Captiva Premium Syringe Filters are available in a wide range of sizes, formats, and membranes to cover every matrix and sample. • Certified. All products are supplied with an HPLC or LC/MS Certificate, guaranteeing extremely low levels of observed extractables. • Exceptional Flow Rate. Captiva syringe filters have excellent flow rates and maximum sample loading capacity. • Highest Quality. Agilent Captiva syringe filters are constructed with the highest-grade virgin polypropylene housing, and are securely welded to prevent bursting and ensure sample integrity.
Disposable Syringes All two-part Captiva disposable syringes are made of high-quality polyethylene and polypropylene. They allow you to accurately dispense liquid volumes and filter samples before analysis, in conjunction with the syringe filter. Features: • 1, 2, 5, 10, and 20 mL disposable syringes • Sterile and non-sterile choices • Luer lock or Luer slip choices
Captiva Glass Layered Filters with Microfiber Pre-Filter.
SPEC (Captiva 10U) 3 mL W.Filter A
PTFE-faced polypropylene filter which is pushed down through the sample to enable in-situ filtering. For use with 50 mL digestion tubes (p/n 190047900).
PTFE membrane filter which is pushed down through the sample to enable in-situ filtering. For use with 50 mL digestion tubes (p/n 190047900).
Includes 5 Captiva filter plates, 10 DuoSeal 96 96-well plate seals, 5 Captiva 96 deep-well 1 mL collection plates, 5 Captiva collection plate pierceable covers
Captiva ND Lipids 96-well filtration replacement kit; includes 2 Captiva NDLipids filter plates, 2 Captiva 96 deep well 1 mL collection plates and 1 captiva collection plate pierceable covers.
Captiva ND Lipids 96-well filtration starter kit; includes 1 CaptiVac vacuum collar, 2 Captiva NDLipids filter plates, 2 Captiva 96 deep well 1 mL collection plates and 1 captiva collection plate pierceable covers.
Captiva 10 µm Filtration replacement kit
Captiva 96-deep well collection plate, 1 mL, 10/pk
Captiva 96 well collection plate, 1 mL, 100/pk
Captiva EMR-Lipid 96WP, 40mg. The 96-well plate and 1 mL cartridge formats contain a solvent retention frit, which allows in-well protein precipitation that streamlines sample preparation. The improved filter design promotes easy flow with vacuum or positive pressure. The easy-to-use 3 and 6 mL cartridge formats allow gravity flow due to the absence of solvent retention frits.
Captiva EMR-Lipid 96WP, 40mg. The 96-well plate and 1 mL cartridge formats contain a solvent retention frit, which allows in-well protein precipitation that streamlines sample preparation. The improved filter design promotes easy flow with vacuum or positive pressure. The easy-to-use 3 and 6 mL cartridge formats allow gravity flow due to the absence of solvent retention frits.
Stainless steel mobile phase filter 10um
Filter extender tube, NW 25 x 100 mm, for Agilent Quiet Cover on LC/MS, GC-QTOF, and ICP-MS instruments
Includes 1 CaptiVac vacuum collar, 5 Captiva filter plates, 10 DuoSeal 96 96-well plate seals, 5 Captiva 96 deep-well 1 mL collection plates, 5 Captiva collection plate pierceable covers
• Protect HPLC columns from clogging to reduce instrument downtime • Clean and clear filtrates offer improved sensitivity • High analyte recovery with simple robust methods allows faster method development
Captiva filter vials remove particulates from your sample and are ideal for simple mechanical filtration. Filtering samples before analysis can extend column lifetime, decrease instrument downtime, and improve sample integrity. Captiva filter vials reduce the steps in your gas chromatography (GC) or high-performance liquid chromatography (HPLC) workflow. Just fill, cover, and plunge! Filter vials are a fast, economical, and environmentally conscience way to filter samples. The single, convenient and easy-to-use unit replaces the combination of syringe filters, syringes, autosampler vials, septa, and caps. With Captiva filter vials, there are fewer touchpoints in the sample journey, meaning fewer chances for contamination. Plus, they allow you to filter only what you need for analysis, saving time. Available in both 0.2 µm (white septum) and 0.45 µm (red septum) pore sizes, as well as nonslit and preslit formats, we have a variety of membrane choices to meet your application needs. Caps are color-coded based on membrane type for easy identification. Choose from polytetrafluoroethylene (PTFE), nylon, polyethersulfone (PES), and regenerated cellulose (RC) membranes. PES filter vials are a great choice for protein analysis applications due to their low protein binding. RC filters are suitable for general filtration for aqueous based samples. Nylon is a versatile filter for particulate filtration from both aqueous and organic matrices, while PTFE is most suitable for organic solvents. Features: • Syringeless filters provide fast, economical sample filtration before GC or HPLC analysis • Filtration takes place inside the vial, reducing the number of steps and required tools or consumables. • Filter vial design eliminates the need for an autosampler vial • Fewer touchpoints in your sample journey mean fewer chances for contamination • Prevents even small particulates from clogging your column inlet, preventing high backpressure, retention-time shift, and resolution loss – which improves data quality • Environmentally-friendly design means less glass and plastic are discarded during sample filtration process • Available in 0.2 and 0.45 µm pore sizes • Nonslit and preslit options available • Color-coded caps based on membrane type for easy identification: PTFE (light blue), nylon (blue), PES (light green), regenerated cellulose (teal) • Closure tool available to use with multiple filter vials simultaneously
Captiva EMR with Carbon S. Captiva EMR (Enhanced Matrix Removal) enables pass-through filtration with selective removal of matrix interferences. For example, Captiva EMR-Lipid removes lipids with a pass-through filtration (resin retains lipids). This selective retention of unwanted analyte interferences has been extended to removal of pigments that interfere with analysis, like chlorophyll. Captiva EMR product line can now be targeted to specific sample types based on interferences. If you have a sample with High Chlorophyll in a Fresh leafy vegetable like spinach, argula, chard, use EMR-HCF1 or EMR-HCF2. If it is a General Pigment Fresh (berries, peppers, broccoli) or General Pigmented Dry (spices, seasoning, Herbal medicine), choose EMR-GPF or EMR-GPD respectively. And for samples that are Lower Pigment and Dried like nuts, tobacco, light pigmented spices, seeds, use EMR-LPD. Features: • Highly selective and efficient removal of matrix interferences: • Clog-free operation: Advanced filter design and construction technology ensures easy flow • Save 15 to 30% sample preparation time and improve precision: No need to develop lengthy Solid Phase Extraction (SPE)-like protocols
Captiva EMR with Carbon S. Captiva EMR (Enhanced Matrix Removal) enables pass-through filtration with selective removal of matrix interferences. For example, Captiva EMR-Lipid removes lipids with a pass-through filtration (resin retains lipids). This selective retention of unwanted analyte interferences has been extended to removal of pigments that interfere with analysis, like chlorophyll. Captiva EMR product line can now be targeted to specific sample types based on interferences. If you have a sample with High Chlorophyll in a Fresh leafy vegetable like spinach, argula, chard, use EMR-HCF1 or EMR-HCF2. If it is a General Pigment Fresh (berries, peppers, broccoli) or General Pigmented Dry (spices, seasoning, Herbal medicine), choose EMR-GPF or EMR-GPD respectively. And for samples that are Lower Pigment and Dried like nuts, tobacco, light pigmented spices, seeds, use EMR-LPD. Features: • Highly selective and efficient removal of matrix interferences: • Clog-free operation: Advanced filter design and construction technology ensures easy flow • Save 15 to 30% sample preparation time and improve precision: No need to develop lengthy Solid Phase Extraction (SPE)-like protocols
Captiva EMR with Carbon S. Captiva EMR (Enhanced Matrix Removal) enables pass-through filtration with selective removal of matrix interferences. For example, Captiva EMR-Lipid removes lipids with a pass-through filtration (resin retains lipids). This selective retention of unwanted analyte interferences has been extended to removal of pigments that interfere with analysis, like chlorophyll. Captiva EMR product line can now be targeted to specific sample types based on interferences. If you have a sample with High Chlorophyll in a Fresh leafy vegetable like spinach, argula, chard, use EMR-HCF1 or EMR-HCF2. If it is a General Pigment Fresh (berries, peppers, broccoli) or General Pigmented Dry (spices, seasoning, Herbal medicine), choose EMR-GPF or EMR-GPD respectively. And for samples that are Lower Pigment and Dried like nuts, tobacco, light pigmented spices, seeds, use EMR-LPD. Features: • Highly selective and efficient removal of matrix interferences: • Clog-free operation: Advanced filter design and construction technology ensures easy flow • Save 15 to 30% sample preparation time and improve precision: No need to develop lengthy Solid Phase Extraction (SPE)-like protocols
Captiva EMR with Carbon S. Captiva EMR (Enhanced Matrix Removal) enables pass-through filtration with selective removal of matrix interferences. For example, Captiva EMR-Lipid removes lipids with a pass-through filtration (resin retains lipids). This selective retention of unwanted analyte interferences has been extended to removal of pigments that interfere with analysis, like chlorophyll. Captiva EMR product line can now be targeted to specific sample types based on interferences. If you have a sample with High Chlorophyll in a Fresh leafy vegetable like spinach, argula, chard, use EMR-HCF1 or EMR-HCF2. If it is a General Pigment Fresh (berries, peppers, broccoli) or General Pigmented Dry (spices, seasoning, Herbal medicine), choose EMR-GPF or EMR-GPD respectively. And for samples that are Lower Pigment and Dried like nuts, tobacco, light pigmented spices, seeds, use EMR-LPD. Features: • Highly selective and efficient removal of matrix interferences: • Clog-free operation: Advanced filter design and construction technology ensures easy flow • Save 15 to 30% sample preparation time and improve precision: No need to develop lengthy Solid Phase Extraction (SPE)-like protocols
Captiva EMR with Carbon S. Captiva EMR (Enhanced Matrix Removal) enables pass-through filtration with selective removal of matrix interferences. For example, Captiva EMR-Lipid removes lipids with a pass-through filtration (resin retains lipids). This selective retention of unwanted analyte interferences has been extended to removal of pigments that interfere with analysis, like chlorophyll. Captiva EMR product line can now be targeted to specific sample types based on interferences. If you have a sample with High Chlorophyll in a Fresh leafy vegetable like spinach, argula, chard, use EMR-HCF1 or EMR-HCF2. If it is a General Pigment Fresh (berries, peppers, broccoli) or General Pigmented Dry (spices, seasoning, Herbal medicine), choose EMR-GPF or EMR-GPD respectively. And for samples that are Lower Pigment and Dried like nuts, tobacco, light pigmented spices, seeds, use EMR-LPD. Features: • Highly selective and efficient removal of matrix interferences: • Clog-free operation: Advanced filter design and construction technology ensures easy flow • Save 15 to 30% sample preparation time and improve precision: No need to develop lengthy Solid Phase Extraction (SPE)-like protocols
ValueLab Round 96-well collection plate, 500 µL
ValueLab 96-well filter plate 0.350 uL, 0.22 μm pore size, polytetrafluoroethylene hydrophilic (PTFE-H)
CHROMABOND Multi 96 mikrotiter plate volume: 96x0.5 mL material: PP
CHROMABOND Multi 96 PP-reservoir-vessels consists of twelve 8-well-strips volume: 96x1.0 mL
CHROMABOND Multi 96 deep-well collecting plate made of polypropylene (PP), volume - 96x2 mL.
96-well polypropylene plates for the simultaneous iltration of 96 samples · Advantages of this high-throughput system are: Economical by saving time and solvent The use of multi-channel pipetters facilitates liquid trans- fer steps Readily adaptable to all common automated and robotic handling systems Minimized dead volume (≤ 40 μL) · Membrane materials correspond to the respective CHROMAFIL® syringe filter
For simultaneous preparation of 96 samples - High-throughput SPE. Silica gel based octadecyl phase, not endcapped. It is a classical and widely used nonpolar material for hydrophobic interactions with a wide variety of organic compounds. Recommended application: For simultaneous preparation of 96 samples, SPE applications (solid phase extraction), VALUELIST.EA.Sample preparation, Clean-up or enrichment
For simultaneous preparation of 96 samples - High-throughput SPE. Unmodified silica gel, polar, weakly acidic. Recommended application: For simultaneous preparation of 96 samples, SPE applications (solid phase extraction), VALUELIST.EA.Sample preparation, Clean-up or enrichment
For simultaneous preparation of 96 samples - High-throughput SPE. Silica gel modified with quaternary amine, strongly basic anion exchanger (SAX). Capacity ~ 0.3 meq/ g, not suited for very strong anions such as sulfonic acids, because these are difficult to elute. Recommended application: For simultaneous preparation of 96 samples, SPE applications (solid phase extraction), VALUELIST.EA.Sample preparation, Clean-up or enrichment
For simultaneous preparation of 96 samples - High-throughput SPE. LLE/SLE phase CHROMABOND XTR made of kieselguhr (also known as diatomaceous earth, hydromatrix, celite) for simultaneous preparation of several samples. No problems with phase separation and no formation of emulsions. Organic solutions need not to be dried after the separation. CHROMABOND XTR provides high recovery rates. Recommended application: For simultaneous preparation of 96 samples, SPE applications (solid phase extraction), VALUELIST.EA.Sample preparation, Clean-up or enrichment
For simultaneous preparation of 96 samples - High-throughput SPE. Spherical, hydrophobic polystyrene-divinylbenzene resin for SPE. High-purity material with highest reproducibility and lowest blank values due to an optimized manufacturing process. Excellent recovery rates especially for the enrichment of pharmaceuticals/active ingredients due to the spherical structure of the particles, very homogeneous surface, and optimized pore structure. Recommended application: For simultaneous preparation of 96 samples, Sample preparation, SPE applications (solid phase extraction), VALUELIST.EA.Clean-up or enrichment
For simultaneous preparation of 96 samples - High-throughput SPE. State-of-the-art spherical polymer for highest demands in solid phase extraction. PS/DVB copolymer with benzenesulfonic acid modification for mixed-mode SPE with strong cation exchange and reversed-phase properties (MCX). Exchange capacity 1.0 meq/g, pKa < 1 and RP capacity 300 mg/g (caffeine in water). High-purity material with ideal flow properties and highest reproducibility. Allows highest reproducibility with extremely low blind values due to an optimized production process. Outstanding recovery rates especially for the enrichment of basic (bases with pKa 2–10) analytes. Recommended application: For simultaneous preparation of 96 samples, Sample preparation, SPE applications (solid phase extraction), VALUELIST.EA.Clean-up or enrichment
For simultaneous preparation of 96 samples - High-throughput SPE. State-of-the-art spherical polymer for highest demands in solid phase extraction. PS/DVB copolymer with benzenesulfonic acid modification for mixed-mode SPE with strong cation exchange and reversed-phase properties (MCX). Exchange capacity 1.0 meq/g, pKa < 1 and RP capacity 300 mg/g (caffeine in water). High-purity material with ideal flow properties and highest reproducibility. Allows highest reproducibility with extremely low blind values due to an optimized production process. Outstanding recovery rates especially for the enrichment of basic (bases with pKa 2–10) analytes. Recommended application: For simultaneous preparation of 96 samples, Sample preparation, SPE applications (solid phase extraction), VALUELIST.EA.Clean-up or enrichment
For simultaneous preparation of 96 samples - High-throughput SPE. State-of-the-art spherical polymer for highest demands in solid phase extraction. Hydrophilic-lipophilic balanced (HLB) N-vinylpyrrolidone-divinylbenzene copolymer. Applicable for a wide range of analyte polarities. Enhanced retention for polar compounds. High loadability and outstanding performance. Water wettable – even if bed runs dry, SPE can be continued. Recommended application: For simultaneous preparation of 96 samples, SPE applications (solid phase extraction), VALUELIST.EA.Sample preparation, Clean-up or enrichment
CHROMABOND Multi 96 collection rack with polypropylene tube strips (twelve 8-well-strips) volume: 96x1.0 mL, material: PP
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.