The 3M™ Freeze Watch™ Indicator consists of a highly sensitive indicator liquid in a specially designed ampoule and is used to monitor temperature-sensitive products that can be damaged by freezing temperatures, reliably indicating whether the product has been exposed to a temperature that is too high or too low. - Selection of different temperatures - Self-adhesive, easy to apply Recommended industry: Bakery products, chemicals, egg products, fish and seafood, meat, poultry, grains & oilseeds, beverages and table water, small animal & livestock feed, dairy products, food supplements, fruits and vegetables, confectionery
Class 4 indicators with endpoint reaction. With chemical coating, change their colour when the sterilization cycle is successfully completed. Indicator strips for steam sterilization or ethylene oxide sterilization. - Steam sterilization colour change from yellow to black - EO sterilization colour change from red to green - Economical due to the possibility of cutting in half - Complies with EN ISO 11140-1
Time/Temperature indicators 3M™ MonitorMark™ 3M™ MonitorMark™ Time Temperature Indicator 9860C solves the challenge of monitoring thermal exposure of temperature-sensitive products during transportation and storage. The large indicator window displays exposure, the smaller windows to the right indicate for how long temperature exposure took place. - Clear display of temperature exceedances and the duration of the exceedance - Self-adhesive, easy to apply Recommended industry: Bakery products, chemicals, egg products, fish and seafood, meat, poultry, grains & oilseeds, beverages and table water, small animal & livestock feed, dairy products, food supplements, fruits and vegetables, confectionery
4-pole adapter. Applications: • for bridging different plug or socket sizes • for connecting existing connections to thermal sensors • for the simple connection of measuring cables with plugs or Lemo® sockets
Securely fixes all thermometers with an outer diameter of 7-8 mm with a flexible seal made of PTFE / silicone and a screw cap made of PPS. Integrated combination nut (Safe-Lab) for simply securing and loosening the conical joint. The medium only comes into contact with PTFE.
Two independent measuring sensors PT 100 in one with PTFE coated stainless steel tube (1.4571). Fall protection ring Ø 12 mm. The connection is made via two Lemo® socket connectors mounted directly on the sensor Size 1, each with 4-wire technology. Applications: »Parallel temperature measurement in aggressive media »Double security through redundant system »Control function through two independent measuring sensors »Suitable for simultaneous temperature measurement and safety switching according to the specifications of DIN EN 61010-2-010 when only one NS or GL nozzle, the measuring sensors are switched separately »Ideal for permanently installed measuring cables »Identical in construction also available in dissipative PTFE-EX
Two independent measuring sensors PT 100 in one with dissipative PTFE-EX coated stainless steel tube (1.4571). Fall protection ring Ø 12 mm, Bore Ø for earth connection 5 mm. The circuits are according to the standard EN 61010-2-010: 2013 spatially separated from each other. The connection is made via two Lemo® plug connections mounted directly on the sensor, Socket size 1, each with 4-wire technology.
PFA-coated, 4-pole measuring cable with Lemo® connections. Due to the 4-wire technology an adjustment with a measuring device is not required. Suitable for all BOLA thermocouples with connection coupling type Lemo®. Applications: • To extend existing measuring cables. • For permanent installation in e.g. deductions.
Immersion sensor class A, PT 100, fall protection ring Ø 5 mm. The connection is made through a white PFA hose Cable (4 m long, 4-wire technology).
Thermocouple K (Ni Cr + Ni) in a PTFE-coated stainless steel tube (1.4571). Probe Ø 8 mm, with pointed probe end, fall protection ring Ø 12 mm. The connection is made using a green PFA-coated cable (1.5 m long). Applications: • for temperature measurement in aggressive media • connection cable offers flexibility from the measuring instrument to the medium
Thermocouple K (Ni Cr + Ni) in a stainless steel tube coated with PTFE (1.4571). Probe Ø 8 mm, with pointed probe end, fall protection ring Ø 12 mm. The connection is made using a green PFA-coated cable (1.5 m long) with mounted SMP connector. Applications: • for temperature measurement in aggressive media • connection cable offers flexibility from the measuring instrument to the medium
Measuring sensor PT 100 in a stainless steel tube encased in PTFE (1.4571). Probe Ø 8 mm, probe tips Ø 6 mm, fall protection ring Ø 12 mm. The connection is made using a PFA-coated cable (1.5 m long, 4-wire technology). Applications: • for temperature measurement in aggressive media • connection cable offers flexibility from the measuring instrument to the medium
Measuring sensor PT 100 in a stainless steel tube encased in PTFE (1.4571). Probe Ø 8 mm, probe tips Ø 6 mm, fall protection ring Ø 12 mm. The connection is made using a PFA-coated cable (1.5 m long), and mounted plug connection type Lemo® socket size 1, 4-wire technology. Applications: • for temperature measurement in aggressive media • connection cable offers flexibility from the measuring instrument to the medium
Measuring sensor PT 100 in a stainless steel tube encased in PTFE (1.4571). Probe Ø 8 mm, probe tips Ø 6 mm, fall protection ring Ø 12 mm. The connection is made using a PFA-coated cable (1.5 m long), and mounted plug connection type Lemo® plug size 1, 4-wire technology. Applications: • for temperature measurement in aggressive media • connection cable offers flexibility from the measuring instrument to the medium
Measuring sensor PT 100 in a stainless steel tube encased in PTFE (1.4571). Probe Ø 8 mm, probe tips Ø 6 mm, fall protection ring Ø 12 mm. The connection is made via a plug connection mounted directly on the sensor Type Lemo® socket size 1, 4-wire technology. Applications: • for temperature measurement in aggressive media • ideal for permanently installed measuring cables • identical in construction also available in dissipative PTFE-EX
FiveGo carrying case including 4 sample bottles
Protective Dust Filters. Dust filters for HC/HE and HR/HG/HB/MJ moisture analyzers prevent dust from entering the instrument through the ventilator. Ideal for dusty or dirty environments.
Rainbow Kit 1 consists of 3 x 2 bottles of 250ml pH buffer solution 4.01, 7.00, 9.21
Connection cable AS9/5m-ST-Triax7
Expand the instrument at any time, adding new measurement parameters.
Low maintenance pH electrodes
Precision Balances: Big Performance in a Compact Footprint. • MonoBloc weighing cell FACT • fully automatic temperature-controlled internal adjustment • MinWeigh warning function • Wind ring for faster settling times • Metal bottom housing (ABS/PC top housing) • 4.5" large color TFT touchscreen • LevelControl function • Statistics – improved management of weighing data • Easy cleaning with QuickLock for glass panels • Extra small footprint • Overload protection • Battery operation • ISO-Log – records important changes, e.g. adjustments, leveling status • Up to 4 Sample ID's – avoid confusion between samples and provides traceability • Passcode protection – only authorized users can make adjustments • 3 interfaces – USB device, USB host and RS232 • Bluetooth option • PC Direct application for easy data transfer (no software needed) • Legal for Trade: No
Solutions for ion-selective perfectION™ combination electrodes
Ammonia GSE. Membrane Kit for GSE Ammonia (3 membranes + electrolyte) Precise determinations Replaceable membranes for an optimal Ion measurement
Protective cover - single - for balance type PG-S
Moisture Analyser HC103 Halogen moisture analyser for advanced requirements in quality and process control. Compact and rugged, with simplified user interface. Even suitable for untrained users. New drying methods can be downloaded in the device via USB port More than 100 pre-configured methods Very fast measurements in only a few minutes Operated via touch screen with intuitive interface Drying process is visualised in real time Results can be transferred via USB or RS232 interface Easy to clean
Connection cable AK9/20m With K8S or K9 plug head
Corded barcode reader for the reading of 1D / linear codes
Gel-Filled Electrode for pH. The InPro 3100 is a pH electrode with temperature sensor, designed for measurement in bioprocesses where CIP and SIP procedures are required. The InPro 3100 offers stable measurement without risk of diaphragm clogging due to the patented Argenthal silver-ion trap reference system. This is a gel-filled electrode that provides effective, accurate pH measurement with low maintenance requirements. This sensor provides fast and precise pH measurement even after repeated autoclaving and sterilization cycles. Features: • Fully autoclavable or sterilizable in-situ • Gel electrolyte reduces maintenance • Resistant to poisoning substances • EHEDG certified • Pressure resistant up to 6 barg (87 psig) • Watertight connector (IP 68) • Integral temperature sensor permits automatic temperature compensation • ISM (digital) or Analogue: Analogue • pH sensor technology: Highly alkaline-resistant glass membrane for the harshest conditions (HA) • Process connection: thread Pg 13.5 • Shaft material: glass • pH Range: 0 – 14 • Operating Temperature (Celsius): 0 °C - 80 °C • Cable Connector: VarioPin • Solution Ground/Redox Metal: Platinum • Electrolyte refillable: No • Reference system: gel electrolyte, ceramic diaphragm, Argenthal with silver ion barrier
Precise ion calibration. With this ready to use ion calibration standard no weighing and dilutiong is required anymore.
Electrolyte TISAB 3 250 ml, ISA solution, fluoride (no dan. goods)
SMP inner capillaries marked
FiveEasy power supply including connecting plug 230V/DC 9V
A glass-body, micro combination pH electrode with S7 screw head. Designed for measurements in NMR tubes. The slim shaft diameter allows measurements of very small sample volumes. The ARGENTHALTM reference system uses silver-ion-free electrolyte. Thereby is no danger of the junction becoming blocked by sulfides or proteins. The S7 sensor head offers flexibility and can easily be connected to any meter.
Tare container holder for volumetric flasks from 20 - 200ml to use on XPE/XS analytical balances Weigh Directly into Tare Containers ErgoClips can be easily assembled on all Excellence XP/XS Analytical Balances, allowing one step dosing directly into the tare container. The ErgoClips safer dosing method substantially reduces contamination risks, enables fast dosing processes and increases productivity.
perfectION™ Calcium membrane module for combined Calcium electrode
Printer catridge ribbon, black, set of 2 ink ribbons. For LC-P, SF-42, GA42 und GA45
Low maintenance pH electrodes
For an easy start, choose one of our ready-to-use kits which includes the pH meter, an application-specific sensor and calibration standards. • pH electrode InLab® Routine Pro-ISM with ARGENTHAL™ reference system and NTC 30 kΩ temperature sensor. The particularly robust HA membrane glass is specially designed for use at high pH values and reduces the alkali error that usually occurs to a minimum Scope of supply: pH meter SevenDirect™ SD20, electrode arm EasyPlace™, pH electrode InLab® Routine Pro-ISM, 3 x 2 calibration buffer sachets pH 4.01, 7.00 and 9.21 or 10.01, protective cover, power supply, get-started-guide
Electrolyte solution KCl ges. 6x250 ml -9810-
Seven2Go Pro micro to A USB cable
Calibration Substance Vanillin 5 g. Certified Reference Substance. This recommended melting point standard comes with a certificate stating the thermodynamic, the FP and the MP Pharmacopeia melting points. The certified melting point is traceable to a primary standard (LGC, London). Suitable for Dropping Point Calibration: Yes USP Melting Point Reference Standard: No
pH-combination electrode with glass shaft, ARGENTAL™ reference system with Ag+trap and S7 electrode head. Cable - please order separately. Specifications Temperature range: 0 ... 80 °C pH range: 0 ... 14 pH Temperature sensor: no Length / Diam.: 60 mm / 3 mm Electrolyte: Fluid, KCl 3 mol/l Diaphragm: Ceramic type Z (pore size 0.9 µm) Membrane resistance at 25 °C: < 1000 MΩ
HCl/thiourea solution Corrosive acidic organic liquid n.o.s. UN 3265, 8, III, (E), diaphragm cleaner 6x250ml
ORP-Elektrode ORP 41 EasySense
Chemical-resistant protective cover for the terminal for HX204 / HS153. The 100% transparent plastic cover protects the terminal from dirt and scratches
O-ring set Si FDA InPro6XXX for InPro6xxx
The InPro 3251i SG/120 is a digital, pre-pressurized, low maintenance ISM pH & ORP sensor combined with a temperature sensor for in-line measurement in demanding applications. The 120 mm version is optimal for short installation lengths. • The InPro 3251i SG/120 provides stable and precise readings at temperatures down to -25⁰ C, thanks to its low temperature pH glass membrane. • This digital pH sensor has Intelligent Sensor Management (ISM) technology, offering predictive diagnostics to reduce maintenance and calibration. • This sensor provides fast and precise pH and ORP measurement, even after repeated autoclaving and sterilization cycles. • This pH sensor features a digital signal and intelligent diagnostics to help manage your maintenance. The sensor provides a clear display of its remaining lifetime, time remaining until calibration, and counts of the SIP and CIP cycles it has undergone. • The InPro 3251i SG/120 is suited for chemical and pharmaceutical production. Its certification covers hazardous zone use, biocompatibility of the electrolyte, and all relevant hygiene and safety regulations. • This sensor can measure both pH and ORP (Redox), and has a built-in digital temperature sensor. It is pressure resistant up to 4 barg (58 psig), has a watertight connector, and can withstand repeated sterilization and autoclave cycles. Specifications: ISM (digital) or analogue: ISM (digital) pH sensor technology: Glass membrane suitable for low temperatures (LoT) pH range: 1 – 11 Reference system: Pre-printed liquid electrolyte, ceramic junction, Argenthal cartridge with silver ion barrier Operating temperature (Celsius): -25°C - 80°C Cable connection: K8S Process connection: thread Pg 13.5 Sterilizable/Autoclavable: Yes Sensor length: 120 mm Certificates and approvals: CE, METTLER TOLEDO quality certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG / T6, EHEDG, ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb, PED Operating pressure (bar): 0 to 4 barg Temperature sensor: digital Shaft material: glass Solution Ground/Redox Metal: Platinum Electrolyte refillable: No