OQ/PV hardware kit for UV-VIS. Includes 2 flow cells, cell passivating fluid, tubing kit, MCT adjustment hook, temperature sensor support, syringes, OQ/PV manual
IQ test sample, certified, for UV/VIS spectrophotometer, 10 mg/L caffeine in water, 50 mL
Tubing kit for UV/VIS OQ/PV tests, to flush flow cell of Agilent 8453 UV-Vis spectrophotometer. Includes tubing, fittings, adapter
Diffuse reflectance wavenumber standard, certified, 1.25 in diameter, PTFE, in durable Delrin holder with a protective cover, typical reflectance of 99% over UV-VIS-NIR spectrum from 250 to 2500 nm
Diffuse reflectance wavelength and wavenumber standard, certified, 1.25 in diameter, PTFE, in durable Delrin holder with a protective cover, typical reflectance of 99% over UV-VIS-NIR spectrum from 250 to 2500 nm. Includes certificate with reflectance data every 50 nm, traceable to NIST
Cuvette, water-filled, fluorescence, for signal-to-noise measurements of Raman band of water
Wear Metal and Metallo-organic Standards Contains Ag, Al, B, Ba, Ca, Cd, Cr, Cu, Fe, Mg, Mn, Mo, Na, Ni, P, Pb, Si, Sn, Ti, V, Zn.
Wear Metal and Metallo-organic Standards Contains Ag, Al, B, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, P, Pb, Si, Sn, Ti, V, Zn
Internal Standard for Oil Analysis, 5000 μg/g Co in 75 cSt Hydrocarbon Oil
Base mineral oil blank, 2 ppm, in 75 cSt mineral oil, 1/2 gal
V-Solv ICP solvent, 1 gal
Standard for metals in biodiesel, contains Ca, K, Mg, Na and P.
Standard for sulfur in biodiesel. Contains sulfur. Packed in 100 ml bottles
Single element calibration standards in mineral oil.
PerkinElmer alternate trace metal drinking pollution and wastewaters I for ICP and AA, 20 μg/mL Al, Fe, V, 10 μg/mL Co, Cu, Mn, Ni, Zn, 5 μg/mL Sb, Be, TL, in 2% HNO3, 100 mL
PerkinElmer alternate trace metal drinking pollution and wastewaters II for ICP and AA, 500 μg/mL Ca, Na, 100 μg/mL Mg, K, in 2% HNO3, 100 mL
PerkinElmer initial calibration verification for ICP, AA, or GFAA, contains (μg/mL) 500 Ca, K, Mg, Na, 200 Al, in 5% HNO3, Ba, 100 Fe, 60 Sb, 50 Co, V, 40 N, 25 Cu, 20 Zn, 15 Mn, 10 Ag, As, Cr, TL, in 5% HNO3, 5 Be, Cd, Se, 3 Pb
PerkinElmer CLP instrument calibration solution 1, 5,000 μg/mL Ca, Mg, K, Na, in 5% HNO3, 125 mL
PerkinElmer UV wavecal solution, 100 μg/mL K, P, S, 20 μg/mL As, La, Li, Mn, Mo, Na, Ni, Sc, 1 μg/mL Ca, in 5% HCl, 500 mL
PerkinElmer Vis wavecal solution, 50 μg/mL K, 10 μg/mL La, Li, Mn, Na, Sr, 1 μg/mL Ba, Ca, in 2% HNO3, 250 mL
PerkinElmer CLP instrument calibration mix 4, 100 μg/mL As, TL, 50 μg/mL Cd, Se, 30 μg/mL Pb, in 5% HNO3, 125 mL
PerkinElmer mixed calibration solution for ICP-OES, 50 μg/mL As, K, 10 μg/mL La, Li, Mn, Ni, Sr, Zn, 1 μg/mL Ba, Mg, in 2% HNO3, 500 mL
Butanetriol-interner Standard für Biodiesel-Analyzer: 1000 µg/ml in Pyridin 1 x 5 ml.
Didymium standard for UV, certified to USP857, NIST traceable
Acetone standard for UV certification to USP857, certified, NIST traceable
Certified standard for specular reflectance measurement at 7 degree angle of incidence, NIST-traceable certificate
ICH Q3D and USP 232 kit, includes 5 standards: 5190-9766, 5190-9767, 5190-9768, 5190-9769, 5190-9770 at 100 mL each
Magnesium standard, 1000 ug/mL, 125 ML, water with trace nitric acid
Complex Cyanide standard, 1000 ug/mL, 125 ML, water with dilute sodium hydroxide
Single Element Inorganic Standards
Anion standards for ion chromatography
Lanthanum (La) buffer, 100,000 μg/mL in 10% HNO3, 500 mL
ICH/USP target elements standard A, Hg 30 µg/mL, As 15 µg/mL, Cd and Pb 5 µg/mL in 2 % HNO3, 100 mL
ICH/USP oral target elements standard B, Ni 200 µg/mL, Ag and Se 150 µg/mL, V 100 µg/mL, Tl 8 µg/mL, Co 50 µg/mL in 2 % HNO3
ICH/USP oral target elements standard C, Au, Ir, Os, Pd, Pt, Rh, and Ru 100 µg/mL in 15 % HCl
ICH/USP oral target elements standard D: Cr 11,000 µg/mL, Sn 6000 µg/mL, Cu and Mo 3000 µg/mL, Ba 1400 µg/mL, Sb 1200 µg/mL, Li 550 µg/mL in 5% HNO3/tr. HF
Pharma internal standard 1: Te 25 µg/mL, Sc 10 µg/mL, Ge, In, Lu, and Bi 5 µg/mL in 2% HNO3/tr. HF
Potassium (K) buffer, 100,000 μg/mL in 2-5% HNO3, 500 mL
Buffers/Ionization Suppressant for Flame AA. Supplied in 500 mL bottles.
Buffers/Ionization Suppressant for Flame AA. Supplied in 500 mL bottles.
Buffers/Ionization Suppressant for Flame AA. Supplied in 500 mL bottles.
ICP-OES Calibration Standards.Kit - contains five bottles: 125 mL of each of the following standards ICM-202 ICM-203 ICM-204 ICM-205 ICP-051
EPA States Standards. Kit - contains four bottles: 50 mL of each of the following standards ICM-221, ICM-223 plus 125 mL of each of the following standards ICP-051, ICM-224
ICP-MS Calibration Standards. Kit − contains six bottles: 125 mL of each of the following standards ICM-231, ICM-232, ICM-233, ICM-234, ICM-235, ICM-642
EPA States Standards
ICP Standards
ICP-OES Calibration Standards
Atomic Absorption Calibration Standards.
ICP-MS Calibration Standards
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.