Tuning Solution for ICP-MS, contains 1 µg/L each of Li, Mg, Y, Ce, Tl and Co in a matrix of 2% HNO3; 2 x 500 mL bottles
Color standard, calibrated, 2 inch od, certified values in 10 nm increments from 380 to 830 nm. Includes 4 colored standards, values traceable to NIST
Tuning solution, Li, Y, Ce, Tl, and Co in 2 % HN03, 10 µg/L, 2 x 500 mL bottles Add to Favorites
Multi-element calibration standard-2A, One bottle contains 10 mg/L. Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, K, Li, Mg, Mn, Na, Ni, Pb, Rb, Se, Sr, Tl, U, V, Zn in a matrix of 5% HNO3. Second bottle contains 10 mg/L Hg in a matrix of 5% HNO3, 2 x 100 mL bottles.
Spectralon diffuse color standards, calibrated, red, green, blue, yellow, for highly stable reproducible spectral reflectance, 2 in diameter
Spectralon 99% reflectance standard, calibrated, for diffuse reflectance, 2 inch diameter, in durable Delrin holder with protective cover
Certified glass neutral density standards to certify UV instruments from 440 to 635 nm for accuracy and linearity to USP
Certified reference standard for certification of UV instruments to USP requirements. Includes 0.006% potassium dichromate plus perchloric acid blank and neutral density filters of 0.5, 0.7 + 1.0 Abs. for photometric accuracy tests. Also includes 4% holmium perchlorate in 10% perchloric acid for wavelength accuracy tests. Each solution is sealed in a quartz cuvette. A certificate of calibration with NIST traceability is included for each solution/filter.
Spectralon 99% reflectance standard, calibrated, for diffuse reflectance, 1.25 in diameter, in durable Delrin holder with protective cover, for DRA-CA-30I. Includes diffuse reflectance data from 250 to 2500, every 50 nm
standard, for ICP-OES and MP-AES
ICP-OES Calibration Standards
Single Element Inorganic Standards for AA and MP-AES
Matrix Modifiers for Graphite Furnace AA
ICP-MS Standards (single element)
Semiquantitative calibration standard 1, in 40% aqua regia, Ag, Al, As, Ba, Bi, Ca, Cd, Ce, Dy, Er, Eu, Ga, Gd, Ho, La, Lu, Mg, Na, Nd, P, Pb, Pr, Rb, Sc, Se, Sm, Sr, Tb, Th, Tl, Tm, U, Y, Yb 10 µg/mL
Semiquantitative calibration standard 2, in 40% aqua regia, trace HF, Au, B, Be, Co, Cr, Cu, Fe, Ge, Hf, Ir, K, Li, Mn, Mo, Nb, Ni, Os, Pd, Pt, Re, Rh, Ru, Sb, Si, Sn, Ta, Te, Ti, V, W, Zn, Zr 10 µg/mL
Tuning and calibration standard 6020 for EPA 200.8, 10 µg/mL Be, Mg, Co, In, Pb, in 5% HNO3, 100 mL
Tuning and calibration standard, 10 µg/mL Li, Co, In, Tl, in 5% HNO3, 100 mL
ICS interference A for EPA 200.7, 5 mg/mL Al, Ca, Mg, 2 mg/mL Fe, in 20% HCl, 500 mL
Initial calibration verification, 1,000 mg/L of Fe, K, Ca, Na, Mg; 100 mg/L of Sr; 10 mg/L of Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, Zn, Th, U in 5% HNO3, 100 mL. Dangerous goods,
Environmental Spike Mix, 100ml - Dangerous Good
Environmental calibration standard, 1000 ppm each of Fe, K, CA, Na, Mg, 10 ppm each of Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, Zn, Th, U in 10% HNO3, 100 mL. Dangerous goods
Neutral density attenuator 1.5 Abs. 1/pk
Calibrated solution validation test kit. Solution validation test kit of 12 sealed cells for testing performance of a UV spectrophotometer (wavelength accuracy, photometric accuracy, stray light, etc). Includes potassium dichromate 40 mg/L, 60 mg/L, 120 mg/L, 600 mg/L plus perchloric acid blank for photometric accuracy tests, holmium perchlorate 4 % in 10 % perchloric acid for wavelength accuracy tests, potassium chloride solution 12 g/L, sodium nitrite solution 50 g/L, sodium iodide - 1 % solution plus water blank for stray light tests, 0.02 % toluene in hexane plus a hexane blank for resolution tests. Each solution is sealed in a quartz cuvette. A certificate of traceability and performance is included for each solution.
ICP-MS Calibration Standards.
6020 Interference Check Solution A. For use with ICP-MS systems, 100 ml bottle, in 5% HNO3 with trace amounts of HF
6020 Interference Check Solution B. For use with ICP-MS systems. Contains: 20 ppm of Cr, Co, Cu, Mn, Ni and V, 10 ppm of As, Cd, Se, and Zn, 5 ppm of Ag. Bottle of 100ml, Matrix = 5% HNO3
ICP-MS Stock Tuning Solution; Li, Y, Ce, Tl and Co; 100 mL, 10 mg/L; matrix 2% HNO3
ICP-MS tuning solution; Li, Mg, Y, Ce, Tl and Co; 100 mL, 10 mg/L; matrix 2% HNO3
ICP-MS checkout solution, required by Agilent installation engineer to validate Agilent 7700 performance on site. Includes tuning solution, dual mode (1), dual mode (2), wash solution, water blank solution
ICP-MS Checkout Solution for 7500s. Contains tuning solution, dual mode (1), dual mode (2), abundance sensitivity (1), abundance sensitivity (2), detection limit solution, high sensitivity tune, wash, and water blank solutions
ICP-MS Checkout Soln for 7500a and 7500i
Quality control standard, QCSTD-27, 100 mL. Contains: Al, Sb, As, Ba, Be, B, Cd, Ca, Cr, Co, Cu, Fe, Pb, Mg, Mn, Mo, Ni, K, Se, Si, Ag, Sr, Na, Tl, Ti, V & Zn at 100 mg/L
Calibration mix 1 for AA and ICP-OES; 125 mL, contains 100 mg/L Sb, Mo, Sn and Tl in 2 % HNO3 + 0.5 % HF
Calibration mix 2 for AA and ICP-OES; 125 mL, contains 100 mg/L Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Se, Tl, Th, U, V and Zn in 5 % HNO3
Calibration mix majors for AA and ICP-OES; 125 mL, contains 500 mg/L Ca, Fe, K, Mg and Na in 5 % HNO3
Calibration mix 3, organic for AA and ICP-OES; 100 mL, contains 500 mg/kg Ag, Al, B, Ba, Ca, Cd, Cr, Cu, Fe, Mg, Mn, Mo, Na, Ni, P, Pb, Si, Sn, Ti, V and Zn in mineral oil
ICP-OES wavelength calibration solution; 500 mL, contains 50 mg/L Al, As, Ba, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Sr, Zn and 500 mg/L K in 5 % HNO3
ICP-OES wavelength calibration solution; 500 mL, contains 5 mg/L Al, As, Ba, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Sr, Zn and 50 mg/L K in 5 % HNO3
Calibration blank solution 5% HNO3 for ICP-OES, MP-AES, and AA, Certified Reference Material, 500 mL
Multi-element calibration standard-4B, 10 µg/mL Ge, Mo, Nb, P, Re, S, Si, Sn, Ta, Ti, Wi, Zr in HNO3/trace hydrofluoric acid, 100 mL
Multi-element calibration standard-1, 10 µg/mL Ce, Dy, Er, Eu, Gd, Ho, La, Lu, Nd, Pr, Sc, Sm, Tb, Th, Tm, Y, Yb in 5% HNO3, 100 mL
Multi-element calibration standard-3, 10 µg/mL Sb, Au, hydrofluoric acid, Ir, Pd, Pt, Rh, Ru, Te, Sn in 10% HCl, 100 mL
Rhodamine B, concentrated solution sealed in triangular cuvette, for collecting excitation correction factors
Fluorescence Calibration Standards
Holmium perchlorate, 4% in perchloric acid, sealed in quartz cuvette, wavelength accuracy standard
Europium in polymer block
Sodium tetrahydridoborate(NaBH4), 500 g, hazardous
OQ/PV standards kit-1, for UV/VIS spectrophotometer. Includes 2 x 10 mL potassium dichromate, 2 x 10 mL sulfuric acid, 10 mL sodium nitrite, 10 mL sodium iodide, 10 mL potassium chloride, 2 x 10 mL hexane, 10 mL toluene in hexane. Dangerous goods
OQ/PV standards kit-2, for UV/VIS spectrophotometer. Includes 2 x 10 mL perchloric acid, 10 mL holmium oxide in perchloric acid. Dangerous goods
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.