Microscopic slides, extrawhite, 76 x 26 mm, double frosted end, ground edges 90°, ISO 8037/I, CE acc. IVD 98/79 EC.
Tube test for the determination of Aluminum. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with NANOCOLOR photometers.
Tube test for the determination of Chloride. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with NANOCOLOR photometers.
Tube test for the determination of TOC. Precise rapid tests for water samples. Time-saving and reliable analysis together with NANOCOLOR photometers.
Standard test for the determination of Phosphate. Reagent kit for highly sensitive photometric measurements with low costs per sample. Pre-programmed on NANOCOLOR photometers.
Reliable, Reusable Glass Cuvettes. The Standard Q macro cuvette with an optical path length of 10 millimeters is made of fused quartz glass and comes in a matching pair. For measurements in the ultraviolet and visible range with a wavelength between 200 nm – 2500 nm. • To ensure high accuracy and reliability of measurements, standard cuvettes come in matching pairs and are manufactured within tolerances of ± 0.02 mm. • Standard line cuvettes provide good optical transparency > 80% and chemical stability. • Standard Q cuvettes are produced in a fire-fusing process, which makes them robust and able to resist even the most corrosive chemicals.
P-58RUE Thermal Printer offers statistics, formulation, totaling applications and label printing with barcode. It can be connected via RS232, USB and ethernet interfaces. The all in one Printer Print on continuous paper, continuous self-adhesive labels or on individual labels with all sample information as well as barcodes. Noiseless speed. Under proper storage conditions, the phenol-free thermal paper is guaranteed to last up to 25 years, whereas the self-adhesive paper only lasts up to 10 years.
Kit for connecting an SPR200 pump to an Excellence density meter or refractometer. Automation for Enhanced Workflow: Sampling and cleaning (1 sample)
Cuvette holder base. Universal Holder required to mount long path length cell holder and solid sample holder The cuvette holder base is required to mount various sample holders, such as the holder for solid samples or for long path length cuvettes.
Cover sample tip SC1/SC
UV/Vis Spectroscopy for Life Sciences. Cuvette-based UV/Vis instrument for life sciences. Pre-defined methods for Bradford, Lowry, BCA and Biuret assays, and for OD600, DNA, RNA and protein analysis (e.g. A260, A260/A280). Accessories available for temperature-controlled kinetic studies. The instrument is shipped ready for immediate use. The Xenon flash lamp has no warm-up time. Simply power it up and start measuring. Comprehensive package of pre-defined Bio-Applications; From DNA concentration and purity determination to protein assays. Main features: • CuvetteChanger • FastTrack™ technology • Compact modularity • Automation • Direct measurements • LabX® UV/VIS software • One Click™ operation • Shortcuts per user: 24 • Max. number of methods: 50 • Automation: Peristaltic pump FillPalMini and SPR200, CuvetteChanger, InMotion Sample Changer, CertiRef™ automatic performance verification • Languages: English /German / French / Spanish /Italian /Portuguese /Russian /Chinese / Japanese • Connectivity: USB devices, Interfaces: Ethernet (PC, network printer), RS232-C • Terminal: 7” QVGA Color TFT 800 x 480 resolution touch sensitive screen Technical Data: Wavelength range [nm] :190−Resolution (toluene in hexane): >1.5 Wavelength accuracy (measured with NIST2034 holmium oxide) [nm]: ±0.9 Wavelength repeatability (measured with NIST2034 holmium oxide) [nm]: < 0.15 Photometric accuracy (measured with NIST935 potassium dichromate) [A]: ±0.005 (≤ 1A) Photometric accuracy (measured with NIST930/1930 neutral density filter) [A] :±0.005 (≤ 1A) Photometric repeatability (measured with NIST935 potassium dichromate) [A] :< 0.002 Photometric repeatability (measured with NIST930/1930 neutral density filter) [A]: < 0.003 Stray light at 198 nm (measured with KCl): > 2.0 A Stray light at 220 nm (measured with KI): >3.5A or <0.03%T Stray light at 340 nm (measured with NaNO2): >3.7A or <0.02%T Noise [A]: < 0.002
Portable device for determining refractive index and derived concentration values. Simple operation and fast results: the sample is either dripped onto the measuring cell or the instrument is immersed directly in the sample liquid. Suitable for laboratory and field measurements, e.g. in food processing or industry. • Automatic temperature compensation • Suitable for measurement of dark samples • Backlit LCD display shows values and menu functions • Calibration with water • Memory for up to 1100 measured values, together with sample ID, unit, temperature compensation coefficient, time and date • Individual formulas for calculation of user-defined concentration data can be defined in the device • Measuring units: nD, nD temperature compensated, Brix% temperature compensated, HFCS42, HFCS55, °Baumé, °Oechsle (D, CH), °KMW (Babo), T.A. 1990, weight %, vol.-%, specific weight and freezing point (in °C or °F) for ethanol and NaCl, weight %, volume % and freezing point (in °C or °F) for ethylene glycol and propylene glycol, weight % and volume % for isopropyl alcohol, user-defined unit • Values can be transferred to the PC via IR interface Refracto 30PX: Optical glass measurement cell Refracto 30GS: Sapphire measurement cell for larger measuring range and faster temperature compensation Scope of delivery: Refracto 30PX/GS, pipette for sample handling, cleaning towels, operating instructions, flasks for sample and cleaning solutions, CD-ROM with software for data transmission, transport case Specifications Refracto 30 PX // Refracto 30 GS Refraction range: 1,32 ... 1,50 // 1,32 ... 1,65 Refraction accuracy: ±0,0005 Refraction resolution: 0,0001 Brix range: 0 ... 85 % Brix accuracy: ±0,2 % Brix resolution: 0,1 % Temperature range: 0 ... 40 °C Temperature resolution: 0,1 °C Dimensions (W x D x H): 62 x 187 x 63 mm Weight: 250 g Power supply: 2 x AAA 1,5 V (please order separately)
The Easy R40 offers fast measurements, a wide temperature control range from 10 to 65 °C, and pre-programmed concentration tables and functions. A compact and robust design makes this instrument suitable for the lab or near the production area. The intuitive app-based user interface and on-screen user guidance simplify daily tasks while minimizing operator errors and training time. Measurement limits can be set for color-coded identification of accepted and rejected samples. • Wide refractive index range • Fast and reliable temperature control (can be turned off for instant results) • LongClick™ – Press and hold the home screen to start routine analysis in 1 second • EasyDirect PC software for efficient data management • Integrated Peltier temperature control • Automatic sample recognition (FastStart™) • Measurement Scales: Chemistry, Refractive Index, Custom Concentration, Sugar (Brix and more), Freezing Point • Languages: English, Italian, Russian, Polish, French, Portuguese, Bahasa, Indonesia, Korean, Chinese, German, Spanish, Thai • 4.3-inch capacitive display with color touchscreen • Connectivity: 3 x USB-A (printer, mouse, keyboard, barcode reader) 1 x USB-B (EasyDirect PC software) • 6 methods
P-56RUE Thermal printer supports printing on thermal paper and continuous thermal labels, and it can be connected via RS232, USB and ethernet interfaces. The state-of-the-art direct thermal printing technology is clean, vibration-free, extremly fast and exceptionally quiet. Print on thermal paper for full documentation of your results. Under proper storage conditions, the phenol-free thermal paper is guaranteed to last up to 25 years, whereas the self-adhesive paper only lasts up to 10 years.
The UV5 Excellence instruments optimize spectroscopic workflows effectively. FastTrack™ technology makes for speedy and reliable measurements. Trustworthy spectroscopic performance is combined with intuitive and efficient One Click™ operation. The UV5 provides simplicity in UV/VIS spectroscopy with easy direct measurement applications. Main features: • 8-position CuvetteChanger • FastTrack™ technology • Compact modularity • Automation • Direct measurements • LabX® UV/VIS software • One Click™ operation • Shortcuts per user: 24 • Max. number of methods: 50 • Automation: Peristaltic pump FillPalMini and SPR200, CuvetteChanger, InMotion Sample Changer, CertiRef™ automatic performance verification • Languages: English /German / French / Spanish /Italian /Portuguese /Russian /Chinese / Japanese • Connectivity: USB devices, Interfaces: Ethernet (PC, network printer), RS232-C • Terminal: 7” QVGA Color TFT 800 x 480 resolution touch sensitive screen Wavelength range [nm] :190−Resolution (toluene in hexane): >1.5 Wavelength accuracy (measured with NIST2034 holmium oxide) [nm]: ±0.9 Wavelength repeatability (measured with NIST2034 holmium oxide) [nm]: < 0.15 Photometric accuracy (measured with NIST935 potassium dichromate) [A]: ±0.005 (≤ 1A) Photometric accuracy (measured with NIST930/1930 neutral density filter) [A] :±0.005 (≤ 1A) Photometric repeatability (measured with NIST935 potassium dichromate) [A] :< 0.002 Photometric repeatability (measured with NIST930/1930 neutral density filter) [A]: < 0.003 Stray light at 198 nm (measured with KCl): > 2.0 A Stray light at 220 nm (measured with KI): >3.5A or <0.03%T Stray light at 340 nm (measured with NaNO2): >3.7A or <0.02%T Noise [A]: < 0.002
Extern. Power Supply 120W (SP)
Tube PowerShower Rinse Flex. Tube to connect with the PowerShower™ to upgrade / install the PowerShower™ unit to the InMotion™ Flex Autosampler.
Handheld Refractometer MyBrix With a full Brix range and 10 integrated sugar-related scales, the MyBrix offers fast measurements of almost any food and beverage sample. A compact, robust, and weatherproof design makes this portable device ideal for field and on-site measurements. The MyBrix measures refractive index and sugar content instantly and precisely: Results are received within just 2 seconds in the desired scale. With a weatherproof design (IP65 rated) and the rubberized keypad, MyBrix is ideal for measurements in the field and near the production line. • compact, lightweight, and designed to fit comfortably in the hand • Measurement scale: Refractive Index, Brix, Brix compensated 20 °C, HFCS 42 / 55 / 90, °Baumé, KMW, Oechsle German / Swiss, °Plato, Wort • Measuring cell: Glass and stainless steel • Display: 1.8" digital LCD • Up to 10,000 readings
Connection tube DE/RE-SC
Cleaning tissues, set of 10, for Refractometer
SimpleCheck™ certified dichlorotoluene standard for instrument performance verification • SimpleCheck™ certified dichlorotoluene standards ensure accurate and reliable results on EasyPlus refractometers. • After inputting the standard data or scanning the barcode on the certificate, users can be guided through the process by on-screen help texts. Safety Data Sheet: www.mt.com/msds
Long path length cuvette holder enables mounting of cuvettes with path lengths ranging from 5 – 50 mm.
Pump SD660 Diaphragm w/Suction Tube. Powerful Membrane Pump. Use the SD660 diaphragm pump to manage reagents and solvents for titration automation. Capable of dosing up to 660 mL/min.
Dot matrix printer, USB interface, print speed 2.3 lines per second, auto settings detection Whether you deal with simple or sophisticated applications, the printer generates fast and clear copies of your results. Print in the language in which your connected Mettler-Toledo instrument is operating. The USB-25 printer has a USB interface which makes connection to your instrument quick and easy.
Transport case for portable density meters and refractometers, empty.
Staining jar made from thick-walled soda glass. For holding microscope slides. Delivery together with a glass lid.
Counting chambers, double net ruling, bright-lined, including 2 cover glasses for haemacytometer, CE acc. IVD 98/79 EC.
Counting chambers, double net ruling, with clamps, including 2 cover glasses for haemacytometer, CE acc. IVD 98/79 EC.
Counting chambers, double net ruling, with clamps, bright-lined, including 2 cover glasses for haemacytometer, CE acc. IVD 98/79 EC.
Counting chambers, double net ruling, including 2 cover glasses for haemacytometer, CE acc. IVD 98/79 EC.
Cover glass for microscopy, DIN 58 884, CE acc. IVD 98/79 EC.
Microscopic slides, extrawhite, 76 x 26 mm, cut edges, CE acc. IVD 98/79 EC.
Microscopic slides, extrawhite, 76 x 26 mm, double frosted end, cut edges, CE acc. IVD 98/79 EC.
Microscopic slides, extrawhite, 76 x 26 mm, ground edges 90°, ISO 8037/I, CE acc. IVD 98/79 EC.
Staining trough, Hellendahl pattern. For 16 microscope slides 76 x 26 mm, soda-lime-glass.
DURAN® Staining Tray. For 10 microscope slided (76 x 26 mm) or any width up to 52 mm, 88 x 40 x 71 mm.
Staining jar, Coplin type. For 10 microscope slides 76 x 26 mm, soda-lime-glass.
Microscope slides. Ground edges 45°, frosted.
Microscope slides. Cut edges.
Colored microscope slides. PRINT, ground edges 90°, rounded corners.
Colored microscope slides. Ground edges 90°.
Staining dish, Schiefferdecker type. For 10 microscope slides 76 x 26 mm, soda-lime-glass.
DURAN® Preparation box. With ground glass plate. The precise grinding of the glass plate and the lower part of the vessel enables a tight closure.
Stainless steel handle for staining tray.
Staining trough, Hellendahl pattern. For 10 microscope slides 76 x 26 mm, soda-lime-glass.
Coated microscope slides. Adhesive ++, with coating, ground edges 90°.
Glass trough. For bench, 108 x 90 x 70 mm, soda-lime-glass.
Cover slips. Thickness 1,5, Automat.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.