Tube test for the determination of Aluminum. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with NANOCOLOR photometers.
Tube test for the determination of Chloride. Precise rapid tests for all kind of water and waste water samples. Time-saving and reliable analysis together with NANOCOLOR photometers.
Tube test for the determination of TOC. Precise rapid tests for water samples. Time-saving and reliable analysis together with NANOCOLOR photometers.
Standard test for the determination of Phosphate. Reagent kit for highly sensitive photometric measurements with low costs per sample. Pre-programmed on NANOCOLOR photometers.
Cuvette holder base. Universal Holder required to mount long path length cell holder and solid sample holder The cuvette holder base is required to mount various sample holders, such as the holder for solid samples or for long path length cuvettes.
UV/Vis Spectroscopy for Life Sciences. Cuvette-based UV/Vis instrument for life sciences. Pre-defined methods for Bradford, Lowry, BCA and Biuret assays, and for OD600, DNA, RNA and protein analysis (e.g. A260, A260/A280). Accessories available for temperature-controlled kinetic studies. The instrument is shipped ready for immediate use. The Xenon flash lamp has no warm-up time. Simply power it up and start measuring. Comprehensive package of pre-defined Bio-Applications; From DNA concentration and purity determination to protein assays. Main features: • CuvetteChanger • FastTrack™ technology • Compact modularity • Automation • Direct measurements • LabX® UV/VIS software • One Click™ operation • Shortcuts per user: 24 • Max. number of methods: 50 • Automation: Peristaltic pump FillPalMini and SPR200, CuvetteChanger, InMotion Sample Changer, CertiRef™ automatic performance verification • Languages: English /German / French / Spanish /Italian /Portuguese /Russian /Chinese / Japanese • Connectivity: USB devices, Interfaces: Ethernet (PC, network printer), RS232-C • Terminal: 7” QVGA Color TFT 800 x 480 resolution touch sensitive screen Technical Data: Wavelength range [nm] :190−Resolution (toluene in hexane): >1.5 Wavelength accuracy (measured with NIST2034 holmium oxide) [nm]: ±0.9 Wavelength repeatability (measured with NIST2034 holmium oxide) [nm]: < 0.15 Photometric accuracy (measured with NIST935 potassium dichromate) [A]: ±0.005 (≤ 1A) Photometric accuracy (measured with NIST930/1930 neutral density filter) [A] :±0.005 (≤ 1A) Photometric repeatability (measured with NIST935 potassium dichromate) [A] :< 0.002 Photometric repeatability (measured with NIST930/1930 neutral density filter) [A]: < 0.003 Stray light at 198 nm (measured with KCl): > 2.0 A Stray light at 220 nm (measured with KI): >3.5A or <0.03%T Stray light at 340 nm (measured with NaNO2): >3.7A or <0.02%T Noise [A]: < 0.002
The UV5 Excellence instruments optimize spectroscopic workflows effectively. FastTrack™ technology makes for speedy and reliable measurements. Trustworthy spectroscopic performance is combined with intuitive and efficient One Click™ operation. The UV5 provides simplicity in UV/VIS spectroscopy with easy direct measurement applications. Main features: • 8-position CuvetteChanger • FastTrack™ technology • Compact modularity • Automation • Direct measurements • LabX® UV/VIS software • One Click™ operation • Shortcuts per user: 24 • Max. number of methods: 50 • Automation: Peristaltic pump FillPalMini and SPR200, CuvetteChanger, InMotion Sample Changer, CertiRef™ automatic performance verification • Languages: English /German / French / Spanish /Italian /Portuguese /Russian /Chinese / Japanese • Connectivity: USB devices, Interfaces: Ethernet (PC, network printer), RS232-C • Terminal: 7” QVGA Color TFT 800 x 480 resolution touch sensitive screen Wavelength range [nm] :190−Resolution (toluene in hexane): >1.5 Wavelength accuracy (measured with NIST2034 holmium oxide) [nm]: ±0.9 Wavelength repeatability (measured with NIST2034 holmium oxide) [nm]: < 0.15 Photometric accuracy (measured with NIST935 potassium dichromate) [A]: ±0.005 (≤ 1A) Photometric accuracy (measured with NIST930/1930 neutral density filter) [A] :±0.005 (≤ 1A) Photometric repeatability (measured with NIST935 potassium dichromate) [A] :< 0.002 Photometric repeatability (measured with NIST930/1930 neutral density filter) [A]: < 0.003 Stray light at 198 nm (measured with KCl): > 2.0 A Stray light at 220 nm (measured with KI): >3.5A or <0.03%T Stray light at 340 nm (measured with NaNO2): >3.7A or <0.02%T Noise [A]: < 0.002
Long path length cuvette holder enables mounting of cuvettes with path lengths ranging from 5 – 50 mm.
Pump SD660 Diaphragm w/Suction Tube. Powerful Membrane Pump. Use the SD660 diaphragm pump to manage reagents and solvents for titration automation. Capable of dosing up to 660 mL/min.
Printer paper, 5 rolls
Adapter for photometer/spectrophotometer. Alignment of the UVette to the height of the light path. Aperture function for optimal light path guidance.
Starterset:80 UVettes + 1 uni- vers.adapter 15mm/8.5mm light center height (incl.GeneQuant)
Macro Vis Cuvettes 300 nm- 900 nm Plastic cuvette for measurements in the Vis range, max. filling volume 4,500 µl, 10 x box of 100
Semi-micro Vis Cuvettes 300 nm- 900 nm Plastic cuvette for measurements in the VIS range, max. filling volume 3,000 µl, 10 x box of 100
Cuvette Rack, 30 wells (3 rows of 10 wells each), 2 pcs., white, autoclavable
Autoanalyser cups for Technicon® analysers. PS. Conical base. Sample cups for use in autoanalysers. Base: Conical
Push-on lid for sample cups 1.5/2.0 ml, PE, for Technicon-Analyzer
Cuvette, four clear sided, macro, PS or UV-transparent, sorted by one cavity number, minimum filling volume 2,5 ml. Suitable for fluorescence spectroscopy. The UV-transparent cuvette can be used from a wavelength of 230 nm and shows nearly no autofluorescence. • Clear, clean optical path • Manufactured under controlled room conditions and packaged fully automatically, without human contact • Packed grouped by mold cavity number to ensure lowest variation of extinction coefficient The UV-transparent cuvettes replace sensitive and expensive glass or quartz cuvettes in many applications. Standard 10 mm light path CERTIFIED LIFE SCIENCE QUALITY: Virgin raw materials, Manufactured under controlled room conditions, Intensive in-process controls, Visual inspections, Batch management, Final product inspection, Proven functionality
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.