Claw for Pumpenkopf SP quick
Tygon® for Hydrocarbons For Single- and Multi-Channel use (not suitable with cassette small) • Application: Especially for hydrocarbons, mineral oil products and distillates • Features: · Ideal for petrol, kerosene, heating oil, cutting solutions and coolants on a glycol base · Resistant to ozone and UV • Material: Thermoplastic soft PVC, translucent yellow • Complies with the standards: GLP conform • Temperature range: -40 to +75 °C • Sterilization: Sterilization is not recommended • Restriction: Not suitable for concentrated acids, lyes, food and pharmaceutics Used with: Acids: good Lyes: good Solvents: conditional Pressure: good Vacuum: good Viscous media: excellent Sterile media: conditional
Mounting flange (Pump head SP standard/vario)
Deep groove ball bearing 6001 VA DIN625 (Pump head SP quick)
Pump head peristaltic SP vario •Suitable for most Heidolph Tubing due to adjustable roller spacing •Convex rollers do not squeeze or crush organic cell cultures •Pump head features ball bearings •Rollers made of stainless steel and aluminum •Depending on drive and Tubing, the flow rate ranges from 2.0 to 4,151 ml per minute
Hei-FLOW Silver 1 Package This package includes: • Hei-FLOW Core 120 • Pump head SP quick 1.6 • 1-m each Tygon® (standard) and Silicone tubing (inner Ø 3.1 mm)
Hei-FLOW Value 06 Peristaltic Pumps For standard applications and liquid transfer •Flow rates of 4.0 - 4,151 ml/min with single-channel pump heads •This pump drive is not suitable for multi-channel operation •Adjust the variable speed from 50 - 600 rpm on the analog control knob. Your speed is held constant even under changing loads •These models feature electronic speed control at an accuracy rate of ±2 % •At the press of a button the pump operates clockwise or counter-clockwise
Electronic motor DC (Hei-FLOW) -- 48V
Toothed belt 267-3MR-9
Multi-channel pump head •Increase your throughput by running up to 12 cassettes small on one single pump drive and pump head system •Separate metering into multiple vessels with different feed rates in a single operation by using different Tubing dimensions to adjust flow rate •Save time: Tubing change is done in just seconds •Change your cassettes easily, even during operation – there are no restrictions •Cassette adjustments and changes are simple, just click in place •No additional purchase of a pump drive needed: upgrade your single-channel pump drive with just one adaptor for multi-channel use and pick the head/cassette configuration that matches your application needs
PCB Line filter (Hei-FLOW)
Tygon® tubing for food For Single- and Multi-Channel use (not suitable for use with Cassette small) • Application: Food industry, well suited to products with high fat content • Features: - Extremely chemical-resistant | e. g. appropriate for the use of - polar solvents - Plasticizer and oil-free - Superior flex life in peristaltic pumps - Translucent to ease visual inspection - Outstanding flexibility • Material: Thermoplastic tube, transparent • Complies with the standards: USP Class VI, FDA (21 CFR 177.2600) • and GLP • Temperature range: -78 to +71 °C • Sterilization: Can be autoclaved for 30 min at 1 bar, sterilized by irradiation or with ethylene oxide Used with: Acids: excellent Lyes: excellent Solvents: good Pressure: good Vacuum: good Viscous media: good Sterile media: good
Lower part painted to RAL9016 (Pump headSP quick)
Frame for pump
Tygon® standard For Single- and Multi-Channel use (not suitable with cassette small) • Application: For standard applications • Features: - Non-toxic, non-oxidizing - Good resistance to acids, bases and inorganic media - Very low gas permeability, good performance life • Material: Thermoplastic soft PVC, transparent • Complies with the standards: FDA (21 CFR 177.2601) and GLP • Temperature range: -50 to +75 °C • Sterilization: Can be autoclaved for 30 min at 1 bar and 120 °C (material may change color) or with ethylene oxide • Restriction: Segregation of plasticizers is possible Used with: Acids: good Lyes: good Solvents: unsuitable Pressure: good Vacuum: good Viscous media: excellent Sterile media: conditional
Tygon® standard Extension tubing for Cassette small • Application: For standard applications • Features: - Non-toxic, non-oxidizing - Good resistance to acids, bases and inorganic media - Very low gas permeability, good performance life • Material: Thermoplastic soft PVC, transparent • Complies with the standards: FDA (21 CFR 177.2601) and GLP • Temperature range: -50 to +75 °C • Sterilization: Can be autoclaved for 30 min at 1 bar and 120 °C (material may change color) or with ethylene oxide•Restriction: Segregation of plasticizers is possible Used with: Acids: good Lyes: good Solvents: unsuitable Pressure: good Vacuum: good Viscous media: excellent Sterile media: conditional
Spindle (Pump head SP quick)
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.