Replacement needles, 5.0 µL 50 mm 26 g bevel tip, 3/pk
Replacement needles, 10 uL 2 in. 22 g LC tip, 3/pk
Agilent syringe needle for Shimadzu, 25 to 500 ul, 23/42/cone, 2/pk
Syringe plunger for CTC Autosampler syringes
Straight Needle, 23 and 26s Gauge Autosampler Syringes. Gold standard autosampler syringes let you use one needle and get the benefits of two. The upper portion of the tapered needle offers the strength of a 23-gauge, while the lower portion at 26s-gauge enables use with split/splitless or on-column injections with 0.53 mm id columns. All standard plungers are stainless steel.
Blue Line Autosampler Syringes with Fitted Plungers. Fitted plunger syringes are recommended for homogeneous liquid samples. Each fitted syringe is individually matched with the plunger for precision injection. Plungers are not interchangeable or replaceable.
Needle kit,pk 3 22g/51mm/PT 3 with nut
Plunger in needle replacement kit for manual syringes.
Needle/plunger replacement part for autosampler syringe.
Plunger, replacement with PTFE tipp for manual syringes.
Syringe plunger for CTC GC, replacement for 10 µL fixed needle syringe
Plunger 2.5ml headspace syringe CTC
Plunger, 10ul ALS syringe, RN, PTFE-tipped
ALS syringe plunger, for fixed needle syringe, PTFE-tip.
Plunger, PTFE tipped replacement for 10 µL, fixed needle syringe
PEEK seat tubing, 0.17mm id 100mm, 2.3uL
Seat capillary, 0.5ml, 0.5mm id
Seat capillary, 1.5ml, 0.9mm id
Capillary, PEEK/fused silica, 75 µm id, 150 mm length, 3x fittings. Needle seat capillary for Micro Well Plate Sampler
Seat Capillary, 100 um, 150 mm, Fused silica/PEEK with 3 fittings
Seat Capillary, Fused Silica/PEEK with fittings
Front seat tube for G2258A 1100/1200 Series dual Loop Autosampler
Back seat tube for G2258A 1100/1200 Series dual Loop Autosampler
The needle should be replaced when it becomes bent, burred or blunt, or when it is leaking or plugged. You should suspect a leak if you notice a trail of buffer crystals on the needle seat. The needle seat can become blocked if the sample contains particulates, as this is the first restriction that the sample experiences. If this occurs, try backflushing the needle seat capillary.
Needle, smpl loadg,SS,Luer, 16 ga, 1/pk
PEEK lür lok needle assembly
Needle Assembly, 900 µL upgrade
Seat Assy for G1329 u-LC auto sampler
Agilent Manual syringe, on-column, 10 uL, removable needle, fused silica (barrel only)
Syringe Fillport for connection 1/16 in. OD, 0.75 in./19 mm Id
ALS Syringe, On-column 5 uL removable needle (barrel only)
Fixed needle headspace syringes feature a sideport needle for gas flushing, in conformance with strict CTC standards. Use with Agilent’s Merlin Microseal to minimize instrument downtime and to prevent lost or compromised data caused by septum leaks and liner contamination.
Autosampler Syringes for Termo Gc Systems.
Autosampler Syringes for PerkinElmer GC Systems
Autosampler Syringes for Bruker/Varian Gc Systems
This syringe has a long needle and regular plunger button for compatibility with HP 7670/71/72 autosamplers. Available with a fixed or removable needle
Syringe, SGE, gas-tight, 23 gauge cone tip, 25 µL
ALS Syringe, 23-26s/42/cone. Gold standard autosampler syringes let you use one needle and get the benefits of two. The upper portion of the tapered needle offers the strength of a 23-gauge, while the lower portion at 26s-gauge enables use with split/splitless or on-column injections with 0.53 mm id columns. All standard plungers are stainless steel.
Syringe for CTC Analytics PAL3 Systems (LSI, RSI 120/RSI 85 and RTC 120).
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.