OMNIJET dispenser, 10-100mL bottle top dispenser
Eco straight-through stopcock plug, undrilled, finest surface, with handle and nut made of PP as well as washer.
Eco straight-through stopcock plug, with bore, finest surface, with handle and nut made of PP as well as washer.
Eco three-way (T) stopcock plug with bore, finest surface, with handle and nut made of PP as well as washer.
Eco two-way (patent) stopcock plug with bore, finest surface, with handle and nut made of PP as well as washer.
Eco stopcock on the side with bore, finest surface, with handle and nut made of PP as well as washer and an outlet tip with an inner Ø of 1 mm.
Measuring cylinder, PTFE / TFM. Translucent and pore-free, design based on ISO 4788. With scaling (not calibrated), spout and reinforcement ring on top. Universally chemically resistant, the medium only comes into contact with PTFE. Applications: Volume measurement of aggressive or ultra-pure liquids
Claw for Pumpenkopf SP quick
Tygon® for Hydrocarbons For Single- and Multi-Channel use (not suitable with cassette small) • Application: Especially for hydrocarbons, mineral oil products and distillates • Features: · Ideal for petrol, kerosene, heating oil, cutting solutions and coolants on a glycol base · Resistant to ozone and UV • Material: Thermoplastic soft PVC, translucent yellow • Complies with the standards: GLP conform • Temperature range: -40 to +75 °C • Sterilization: Sterilization is not recommended • Restriction: Not suitable for concentrated acids, lyes, food and pharmaceutics Used with: Acids: good Lyes: good Solvents: conditional Pressure: good Vacuum: good Viscous media: excellent Sterile media: conditional
Mounting flange (Pump head SP standard/vario)
Deep groove ball bearing 6001 VA DIN625 (Pump head SP quick)
Pump head peristaltic SP vario •Suitable for most Heidolph Tubing due to adjustable roller spacing •Convex rollers do not squeeze or crush organic cell cultures •Pump head features ball bearings •Rollers made of stainless steel and aluminum •Depending on drive and Tubing, the flow rate ranges from 2.0 to 4,151 ml per minute
Hei-FLOW Silver 1 Package This package includes: • Hei-FLOW Core 120 • Pump head SP quick 1.6 • 1-m each Tygon® (standard) and Silicone tubing (inner Ø 3.1 mm)
Hei-FLOW Value 06 Peristaltic Pumps For standard applications and liquid transfer •Flow rates of 4.0 - 4,151 ml/min with single-channel pump heads •This pump drive is not suitable for multi-channel operation •Adjust the variable speed from 50 - 600 rpm on the analog control knob. Your speed is held constant even under changing loads •These models feature electronic speed control at an accuracy rate of ±2 % •At the press of a button the pump operates clockwise or counter-clockwise
Electronic motor DC (Hei-FLOW) -- 48V
Toothed belt 267-3MR-9
Multi-channel pump head •Increase your throughput by running up to 12 cassettes small on one single pump drive and pump head system •Separate metering into multiple vessels with different feed rates in a single operation by using different Tubing dimensions to adjust flow rate •Save time: Tubing change is done in just seconds •Change your cassettes easily, even during operation – there are no restrictions •Cassette adjustments and changes are simple, just click in place •No additional purchase of a pump drive needed: upgrade your single-channel pump drive with just one adaptor for multi-channel use and pick the head/cassette configuration that matches your application needs
PCB Line filter (Hei-FLOW)
Tygon® tubing for food For Single- and Multi-Channel use (not suitable for use with Cassette small) • Application: Food industry, well suited to products with high fat content • Features: - Extremely chemical-resistant | e. g. appropriate for the use of - polar solvents - Plasticizer and oil-free - Superior flex life in peristaltic pumps - Translucent to ease visual inspection - Outstanding flexibility • Material: Thermoplastic tube, transparent • Complies with the standards: USP Class VI, FDA (21 CFR 177.2600) • and GLP • Temperature range: -78 to +71 °C • Sterilization: Can be autoclaved for 30 min at 1 bar, sterilized by irradiation or with ethylene oxide Used with: Acids: excellent Lyes: excellent Solvents: good Pressure: good Vacuum: good Viscous media: good Sterile media: good
Lower part painted to RAL9016 (Pump headSP quick)
Frame for pump
Tygon® standard For Single- and Multi-Channel use (not suitable with cassette small) • Application: For standard applications • Features: - Non-toxic, non-oxidizing - Good resistance to acids, bases and inorganic media - Very low gas permeability, good performance life • Material: Thermoplastic soft PVC, transparent • Complies with the standards: FDA (21 CFR 177.2601) and GLP • Temperature range: -50 to +75 °C • Sterilization: Can be autoclaved for 30 min at 1 bar and 120 °C (material may change color) or with ethylene oxide • Restriction: Segregation of plasticizers is possible Used with: Acids: good Lyes: good Solvents: unsuitable Pressure: good Vacuum: good Viscous media: excellent Sterile media: conditional
Tygon® standard Extension tubing for Cassette small • Application: For standard applications • Features: - Non-toxic, non-oxidizing - Good resistance to acids, bases and inorganic media - Very low gas permeability, good performance life • Material: Thermoplastic soft PVC, transparent • Complies with the standards: FDA (21 CFR 177.2601) and GLP • Temperature range: -50 to +75 °C • Sterilization: Can be autoclaved for 30 min at 1 bar and 120 °C (material may change color) or with ethylene oxide•Restriction: Segregation of plasticizers is possible Used with: Acids: good Lyes: good Solvents: unsuitable Pressure: good Vacuum: good Viscous media: excellent Sterile media: conditional
Spindle (Pump head SP quick)
Spare part kit: Cap (Pump head SP standard)
Spare part kit: Coupling Pump drive
Cable harness with potentiometer
Fitting for extension. For tubing diameter 0.2 - 2.8 mm, tubes Accessories
Frame for pump
PCB controller for pump PD
Knurled screw for pump head (SP quick)
Cassette small • Flow rates from 0.005 to 37 ml/min • Suitable for tubes with 0.9-mm wall thickness (wt) • Tube diameters available: 0.2 / 0.5 / 0.9 / 1.4 and 2.8 mm • Two-Stop Tubing (40 cm) required to operate cassette small • Stoppers secure tube in place • Couplings and tube extensions allow extra hose length in 1-m increments Combinations: • C 4 multi-channel pump head: Max. 4 cassettes small • C 12 multi-channel pump head: Max. 12 cassettes small
Threaded pin screw M5x16
Inlet distributor for Rotavac Vario Pumping Unit
Power supply - 100W for Hei-FLOW peristaltic pumps
The ability to switch between precise dosing and fast conveying make this pump model the perfect complement to a reactor system. With a flow rate of 2.0 - 4,056 ml / min, when operated with single-channel pump heads, flows from feed-batch and chemostat modes of operation can be conveyed precisely. Rapid filling and emptying of the reactor system is also possible. In addition to the selectable process parameters - speed, tubing diameter, flow quantity display, dosing volume, interval dosing and break times - the pump conveying characteristics are stored in the program. Thanks to the analogue and digital (RS 232) interfaces, processes can be automated. All media is conveyed with a control accuracy of ±2% at a speed of 24 — 600 rpm. An optional foot switch can be connected for dosing by foot pressure.
Spacer disc V2A for Pump head SP quick
Single-Channel Pump Heads SP standard (wall thickness 2.0 mm)
Cable harness switch (PD 50xx)
Sealing ring (V-ring) V 16A
The pump drive of the model 120 of the Hei-FLOW Expert series can be operated with either single-channel or multi-channel pump heads. The flow rates with single-channel pump heads are in the range of 0.38 — 813 ml/min; with multi-channel pump heads from 0.005 — 329 ml/min. By integrating an analog interface, it is possible to control all functions externally. In addition, an optional foot switch can be adapted to enable dosing by foot pressure. Hands thus remain free to perform other work, for example, to hold the tubing and the vessel. A speed of 5 — 120 rpm with a control accuracy of ±3.5% guarantees optimum process results. Multi-Channel Operation • Increase your throughput by running up to 12 individual cassettes on one single pump drive and pump head system • Separate metering into multiple vessels with different feed rates in a single operation by using different tubing dimensions to adjust flow rate • Save time: tubing change is done in just seconds • In addition to standard pump heads which feature a 4-roller system you can choose 8-roller pump heads for low pulsation • Change your cassettes easily, even during operation – there are no restrictions • Cassette adjustments and changes are simple, just click in place • No additional purchase of a pump drive needed: upgrade your single-channel pump drive with just one adaptor for multi-channel use and pick the head/cassette configuration that matches your application needs
PharMed® Extension tubing for Cassette small • Application: Ideal for medical, lab and research uses • Features: o High fatigue strength under repeated reversed bending stresses o Non-toxic, biocompatible o Very low gas permeability o Well suited to acids and bases • Material: Thermoplastic elastomer on a polypropylene base with plasticizers; excellent tensile strength; opaque • Complies with the standards: USP Class VI, GLP, Pharmacopoea and Europaea • Temperature range: -51 to +135 °C • Sterilization: Can be autoclaved or sterilized with ethylene oxide or sterilized by irradiation • Restriction: Additives may migrate Used with: Acids: good Lyes: good Solvents: unsuitable Pressure: good Vacuum: excellent Viscous media: good Sterile media: excellent
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.