OQ requalification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet)
4 - 20 mA current loop interface (0 to +310 °C = 4 - 20 mA); Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) - price per sensor
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet)
OQ requalification on site including temperature distribution survey with 27 temperature measuring points, 1 CO2 measuring point and 1 O2 measuring point in centre of usable space for a freely selectable temperature, CO2 and O2 value according to DIN12880:2007-05 (requires option T6) (travel costs are not included yet)
Water baths WNB The Memmert waterbath is available in six model sizes and two performance classes. In addition to the Basic class for standard temperature control tasks, the Excellent version provides precise test procedures with a maximum of safety. The 3-sided heating ensures excellent temperature homogeneity. WNB = water bath, natural circulation, temperature controller BASIC with 2-fold overtemperature protection WNE = water bath, natural circulation, temperature controller EXCELLENT with 3-fold overtemperature protection, filling level control and calibration option Specifications: • Working-temperature range: at least 5 °C above ambient to +95 °C and additional boiling stage • Setting temperature-range: +10 °C to +95 °C and boiling stage • Temperature variation: ± 0,1 K • Temperature distribution: ± 0,25 K (sizes 7 - 29), ± 0.3 K (size 45) • Power supply: 230V, 50/60Hz; 115 V, 50/60 Hz no extra charge Water bath with natural circulation and temperature controller BASIC with 2-fold overtemperature protection Without covers - please order separately!
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (requires option K7) (travel costs are not included yet)
IQ/OQ document with device-specific works test data, including temperature distribution survey with 5 temperature measuring points and 1 pressure measuring point each thermoshelf at Memmert factory for a freely selectable temperature and pressure value according to DIN12880:2007-05 (PQ check list as support for validation by customer), valid for one thermoshel, price for every further thermoshelf on request
Universal oven UN Precise drying, heating, tempering, aging, baking, testing and hardening in research, science, industry and quality assurance. This universal heating and drying oven is the Memmert classic for temperature control in science and research as well as for material tests in industry. The technologically perfected masterpiece made of high-quality, hygienic, easy-to-clean stainless steel leaves nothing to be desired in terms of ventilation technology, control technology, excess temperature protection and precisely coordinated heating technology. Whether you are carrying out material tests, aging computer chips, running complex test series with highly sensitive loads, drying or tempering electronic components, hardening synthetic resin or heating up plasticine, the Memmert heating cabinet / drying cabinet U stands for unsurpassed precise, even and gentle tempering. • Natural convection, SingleDISPLAY • Working temperature range at least 5 °C above room temperature up to +300 °C • Setting temperature range +20 °C to +300 °C • Setting accuracy up to 99.9 °C: 0.1 °C / from 100 °C: 0.5 °C • Stainless steel door • Electronically adjustable exhaust air flap from 0% - 100% in 10% increments, • Ethernet interface for reading out the protocol data • double over-temperature protection • Integrated data logger with storage capacity for at least 10 years • Setting of 3 calibration values on the ControlCOCKPIT • Factory calibration certificate for +160 °C • Housing and interior made of stainless steel • Voltage: 230 V, 50/60 Hz (sizes 30 - 260), 400 V (sizes 450 - 750)
Central water supply, with filter cartridges for connection to the domestic water supply (requires option K7). Product information on demand
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 26 temperature measuring points (size 1400) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer)
Peltier-cooled incubators IPP Heating and cooling seamlessly with one system thanks to Peltier technology. In this respect, cooled incubators IPP not only contribute to climate protection, but it also achieves an additional decrease in operating costs of up to 90% compared to compressor technology.•Extremely quiet, vibration-free and space saving as no compressor is required •No condensation in the interior chamber: due to the closed Peltier cooling system no outside air is exchanged •LED light module for sizes 110 to 750 (as an option): dimmable LED light in three alternative colour temperatures (cold white light, warm white light or cold white and warm white light, dimmable in steps of 1 %) Specifications: • SingleDISPLAY: ControlCOCKPIT with one colour display • Working temperature range without light: 0 (at least 20 below ambient) to +70 °C • Working temperature range with light: +10 to +40 °C • Setting temperature range: 0 to +70 °C • Setting accuracy: 0.1 °C • Power supply: 230 V, 50/60 Hz • Included grids. 1
Clip for 200 ml flask, max. flasks see sketch on demand
Flat stainless steel cover with openings and concentric ring sets for WTB Water Bath
N2 pressure reducing valve to DIN EN ISO 2503, incl. gas cylinder monitor (requires option T6)
Hot air steriliser SFplus Sterilization instead of disinfecting vessels and instruments in the laboratory. A hot air sterilizer protects and preserves life in medicine. The indispensable safety feature for this hot air steriliser: Setpoint Wait. This means that the programme for sterilisation only starts when the set temperature has been reached. This feature can also be used with freely positionable Pt100 temperature sensors. Here the sterilisation time only begins when the set temperature has been reached at all measurement points, and reliable sterilisation is guaranteed at all times. Specifications: forced air circulation, with TwinDISPLAY, 32 l working-temperature range at least 10 °C above ambient temperature to +250 °C setting temperature range +20 °C to +250 °C with 1 grid (30-55), with 2 grids (75-750) stainless steel door electronically adjustable air flap from 0 to 100 % in 10 % steps and adjustable fan speed from 0 % to 100 % in 10 % steps Ethernet interface for reading out protocol log uploading programmes and for online logging USB port on ControlCOCKPIT for use of USB stick multiple overtemperature protection internal data logger with storage capacity of at least 10 years calibration facility; works calibration certificate at +160 °C • Housing and interior made of stainless steel • Voltage: 230 V, 50/60 Hz, 400 V, 50/60 Hz (size: 450-750)
Subframe, on castors (height 120 mm; stainless steel, material 1.4301)
Process-dependent programmable door lock (only for units with TwinDISPLAY); One
Subframe, adjustable in height (size 30 to 55/75: height 600 mm, size 110 to 450: height 500 mm) for Universal oven UN / UF
Water bath with circulation pump WPE45 The Memmert waterbath is available in six model sizes and two performance classes. In addition to the Basic class for standard temperature control tasks, the Excellent version provides precise test procedures with a maximum of safety. The 3-sided heating ensures excellent temperature homogeneity. WNB = water bath, natural circulation, temperature controller BASIC with 2-fold overtemperature protection WNE = water bath, natural circulation, temperature controller EXCELLENT with 3-fold overtemperature protection, filling level control and calibration option Specifications: Working-temperature range: at least 5 °C above ambient to +95 °C and additional boiling stage Setting temperature-range: +10 °C to +95 °C and boiling stage Temperature variation: ± 0,1 K Temperature distribution: ± 0,25 K (sizes 7 - 29), ± 0.3 K (size 45) Power supply: 230V, 50/60Hz; 115 V, 50/60 Hz no extra charge •fuzzy-supported, PID microprocessor controller with integral autodiagnostic system and fault indication •solid state switching unit •2 class A, 4-wire Pt100 sensors, mutually monitoring and controlling performance at the same temperature value •digital timer from 1 min to 999 hours for: On (continuous operation) Delayed On Hold, or set temperature-dependent Hold, with fixed dwell time•pump can be switched on and off •pump is switched off at programme end •digital display (LED) of all set parameters, such as temperature, time and alarm values •Calibration facility on controller •audible and visual alarms at programme end, as input keypress confirmation and if low liquid level occurs (heating is switched off automatically) Triple Overtemperature Protection:•in case of overtemperature due to fault the heating is switched off at approx. 10°C above the set temperature (fixed value) •independent, class 3.1, TWW electronic overtemperature controller or class 2, TWB overtemperature limiter, are adjustable in set-up menu by the user •mechanical class 1 TB temperature limiter switches the heating off at approx. 30°C above max. bath temperature •set value display resolution: 0.1°C below 99.9°C, 1°C above 100°C •Textured, grade 1.4301 (ASTM 304), corrosion resistant, stainless steel housing Without covers - please order separately.
Integration of additional units (up to max. 31 units) into an already existent FDA-software licence
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7)
Maintenance contract on site HPPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet)
Cooled incubators with compressor cooling ICP The cooled incubators with the unique ControlCOCKPIT for a quick and intuitive operation. Ideal at temperatures around zero and below. For rapid and precise alternation between heating up and cooling down times in ramp operation. Extraordinarily quiet. Standard equipment : •PID microprocessor control with integrated auto-diagnostic system •Interior stainless steel, material 1.4301 (ASTM 304) very stable and easy to clean •Structured stainless steel housing, scratch-resistant, robust and durable; rear of zinc-plated steel (all sizes mounted on lockable castors) •High-temperature connectors on the rear of the appliance for single-phase power connection according to country specific systems and IEC standards •Internal data logger with a storage capacity of at least 10 years •German, English, French, Spanish, Polish, Czech, Hungarian language settings available on the ControlCOCKPIT •Digital backwards counter with target time setting adjustable between 1 minute and 99 days •The SetpointWAIT function guarantees that the process time does not start until the set temperature is reached at all measuring points - optional for temperature values recorded by the freely positionable Pt100 sensors inside the chamber. •Adjustment of three calibration values for temperature and additional appliance specific parameters directly at the ControlCOCKPIT TwinDISPLAY: ControlCOCKPIT with two TFT colour displays•Available parameters on the ControlCOCKPIT: Temperature (Celsius or Fahrenheit), fan speed, exhaust air flap position, programme time, time zones, summertime/wintertime •Two Pt100 sensors DIN class A in a 4-wire circuit for mutual monitoring, taking over functions in case of an error •AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port •ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function •Displaying of already logged protocol data on the ControlCOCKPIT (max 10,000 values correspond to approx. 1 week) •Ethernet interface on the rear of the appliance for reading out the protocol log and for uploading programmes and for online logging •Multiple overtemperature protection: Electronic temperature monitoring TWW/TWB (protection class 3.3 or 2) and mechanical temperature limiter TB (protection class 1) acc. to DIN 12880, AutoSAFETY automatically adjusts to the set value within a freely adjustable tolerance range. Setting individual MIN / MAX values for over/undertemperature alarm Specifications Working temperature range: (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over) -12 to +60 °C (ICP55: 0 to +60 °C) Setting temperature range: -12 to +60 °C (ICP55: -5 to +60 °C) Setting accuracy: 0.1 °C Power supply: 230 V, 50/60 Hz; 115 V, 50/60 Hz at extra cost Included grids 2 Rated capacity 1.2 kW
Stainless steel gable cover for WTB Water Bath
Interior nearly gastight - technical clarification required for combination with other options
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh
Maintenance on site HCP according to Memmert maintenance plan (available on request) (travel costs are not included yet)
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances
Holder for water tank (2.5 litres) for mounting on the rear of the appliance. Standard equipment for size 750
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/410/750, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6
4 - 20 mA current loop interface (0 to +310 °C = 4 - 20 mA); Temperature controller, actual value
Climatic test chamber CTC265, 256 l, -42 °C to +190 °C without humidity, +10 °C to +95 °C with humidity, humidity adjustable from 10 98 % rh, adaptive, fuzzy-supported, multifunctional, digital PID microprocessor controller with auto-diagnostc system; 2 Pt100 sensors, USB interface incl. Celsius software for programming and documentation, printer interface, longtime documentation according to the GLP guidelines (ring memory as datalogger) of all relevant data, twin compressor, adjustable speed condenser fan and electronically controlled refrigerant injection; chlorine-free, ozone-neutral refrigerant R449A, stainless steel interior, hermetically welded, 3-layer high tech insulation, with 1 grid, heated stainless steel door, telescopic slide for 2 x 10 l tanks for destilled water as fresh water and 2 x 10 l as condensate collector, automatic water tank changer-over with alarm for continuous operation, over- and undertemperature protection; works calibration certificate at -30 °C and +160 °C; textured stainless steel exterior: 898 x 1730 x 1100 mm; stainless steel interior: 640 x 670 x 597 mm; voltage: 400 V, 3ph N, 50 Hz; max. electrical load: approx. 7000 W
4 - 20 mA current loop interface; Humidity controller, actual value (0 to 100 % rh = 4 - 20 mA) (requires option K7 or K6)
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet)
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge)
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and CO2 value
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101)
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution, only in connection with option K1)
Entry port with 23 mm clear diameter, can be closed, standard position (F1 and F3 not for models ICHeco L/ICH L); left centre/top
4 - 20 mA current loop interface; Temperature controller actual value (-20 to +70 °C = 4 - 20 mA)
Subframe, adjustable in height (size 30 to 55/75: height 600 mm, size 110 to 450: height 500 mm) for incubators
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software
Temperature restriction; Temperatures: +60, +70, +80, +95, +100, +120, +160, +180 or +200 °C (Please indicate upon ordering)
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.