Stainless Steel Hexnuts and PEEK Ferrules, 10 Hexnuts & 10 Ferrules
Hexnut Fittings :
Stainless steel 10-32 thread fittings use a non-swaging Kel-F™ or PEEK™ replaceable ferrule
Inert contact surfaces make them biocompatible
Ideal for applications where corrosive solvents are being used
Hexnut with Kel-F™ or PEEK™ ferrules are recommended for use with SGE GLT™ columns
Specifications:
Maximum Pressure Rating 5,000psi
Thread Type 10-32
SilTite metal - initial installation for Shimadzu GC-2014, GC-2010, GC-17A and GC-14A detector/injectors, and QP5000/5050 standard MS interface (not for MS interfaces or QP2010 injector) (10 ferrules, 2 nuts)
Gas filter - Carrier gas
The gas purifier system consists of two key parts: the connecting unit and the filters.
The connecting unit has inlet and outlet connectors for the gas lines, and the system can be wall-mounted or fixed to a bench. Connecting units come with a 1, 2 or 4 filter capacity and are available for 1/4" or 1/8" gas lines.
Each gas filter consists of adsorbent packed into a transparent and virtually unbreakable, heavy-walled polycarbonate housing.
With the ability to inject down to 50nL with high precision and accuracy, SGE NanoVolume Syringes are perfect for nanovolume capillary chromatography injection.
The sample is only drawn up into the needle, not the syringe barrel. When the plunger is depressed, the sample is completely dispensed by the NanoVolume plunger that extends right to the tip of the needle.
The plungers and needles are matched sets and must be replaced as a set.
• Reliably seal against the carrier gas pressure in the inlet.
• Capable of being pierced and resealing time after time without pieces of the septa
being deposited in the GC inlet system.
• Does not contaminate or bleed material into the chromatographic system.
Features and Benefits:
• Premium septum for autosamplers with up to 400 injections per septum.
• Comes supplied in a blister pack which prevent absorption from the environment.
Recommended Applications:
•Premium septa for autosamplers with up to 400 injections per septum.
HPLC Unions are specifically designed and precision engineered for use in capillary LC. The ideal way to avoid any void or dead volume in a connection is to achieve a faultless butt connection.
Features and Benefits
• Zero dead volume design for no peak dispersion.
• Easy to use.
• Complete versatility - allows connection to the same or different sized tubing.
• Available in PEEK and stainless steel.
• Stainless steel unions can be finger tightened or tightened with a
3/16" wrench for high-pressure applications.
• PEEK unions can be finger tightened. They are slightly larger than stainless steel unions but also lighter - less stress on your tubing.
Recommended Applications
ProteCol® Unions and reusable PEEK ferrules allow you to connect any combination of:
• 1/32" PEEKsil®.
• 1/16" PEEKsil.
• 0.36 mm fused silica tubing.
Use for connecting guard or trap columns to analytical columns, or for bypassing the analytical column.
Connections | HPLC Unions
Perfect Connections, Every Time PEEK ferrule Fused silica lined PEEK – PEEKsil
Product Specifications
ProteCol unions are available in either stainless steel or PEEK (for all sizes). All use the same range of reusable PEEK ferrules.
Pressure Rating 5000 psi for the stainless steel unions, 2175 psi for the PEEK unions.
eVol® xr digital analytical syringe is the coupling of two precision devices: a digitally
controlled electronic drive and an XCHANGE® enabled analytical syringe.
eVol xr syringes are easily and quickly changed allowing them to be dedicated to
individual liquids or methods to prevent possible cross-contamination of reagents.
The SGE RAX repeating adaptor improves precision and reproducibility when repeatedly dispensing the same volume manually.
The RAX is suitable for syringes with capacities from 500 nL through to 500 μL (except those with Plunger Stops, or Diluter / Dispenser Syringes). The one RAX adaptor can be used on both 6.5mm OD and 8mm OD syringe barrels.
It has easy to use finger grips and can be set to any desired volume.
The RAX can be used as added protection against both plunger blow out at elevated pressures and plunger bending.
The flat sides allow it to sit securely on the bench with the needle in a raised position helping to prevent damage from rolling.
The RAX is supplied with an innovative double-ended tool to facilitate assembly, it can easily and quickly be installed and if required it can readily be removed, replaced or swapped between syringes.
BP5MS GC Capillary Column
•Perfect for your 5% GC-MS analysis.
•Optimized Silphenylene content for general purpose MS analyses.
Application Areas: 5% GC-MS analyses
Stainless Steel 1/16 " Male-Female Tee Connector and Ferrules
•the coupling makes it easy to connect 1/16" OD tubing to an SGE assembly,
•provides an inert demountable flow line for 1/16" male fitting .
PEEKsil™ Injection Loop
• Smooth, non-reactive internal bore reduces sample carry-over and sample rinse times.
• Reduced sample loss due to shear or adsorption.
• Maximum operating pressures are 3000 psi for 10 μL, and 20 μL loops.
• Supplied with PEEKsil™ tubing and two sets of stainless steel Hexnuts™ with PEEK™ ferrule fi ttings.
• Compatible with most valves including Rheodyne® and Valco®.
Capillary Electrophoresis Tubing
• Manufactured from precision bore tubing.
• Hydrophobic and hydrophilic surface
treatments are available to enable
tubing use with proteins, peptides and
enzymes.
• Wide pH range.
• 30, 50, 75 and 100 μm ID.
• Column-to-column reproducibility.
With the ability to inject down to 50nL with high precision and accuracy, SGE NanoVolume Syringes are perfect for nanovolume capillary chromatography injection.
The sample is only drawn up into the needle, not the syringe barrel. When the plunger is depressed, the sample is completely dispensed by the NanoVolume plunger that extends right to the tip of the needle.
The plungers and needles are matched sets and must be replaced as a set.
SGE Dispenser and Pump Syringes incorporate Diamond Technology, taking advantage of
new and innovative technologies and bringing those benefits to your laboratory.
Replacement for Hamilton C and CX Syringes.
Product Specifications:
• 60 mm stroke.
• 1/4-28 UNF thread connection.
• 6-32 UNC thread in plunger button. CX has a button stop.
• 25 μL to 10 mL capacities.
• Operating temperature range (10 °C to 40 °C).