DisQuE QuEChERS, Specialty Cleanup Tubes, 150 mg MgSO4, 25 mg PSA, 25 mg C18 and 7 mg GCB, 2 mL Tube, 100/pkg
XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Replacement O-rings for the 19x10mm Prep Guard Holder (Part Number 186008745). These o-rings are considered both SFC and LC mobile phase compatible.
DisQuE Quecher, 1.5 g Sodium Acetate and 6 g MgSO4, 50 mL Tube, 100/pkg, Mass Spec Compatible. This is tube contains the salts required for the extraction step in QUECHERS AOAC Method 2007.01. QUECHERS (pronounced catchers) methods are used for multi-pesticide residue analyses in food. This is a 100 pack of tubes containing the salts.
The HSS C18 SB (Selectivity for Bases) is an unendcapped, low-coverage C18 bonded-phase column that was designed specifically to provide increased silanophilic interactions. This results in an alternate selectivity compared to a high-coverage fully-endcapped C18 column, particularly for basic compounds.
Sep-Pak Amino Propyl (NH2) Plus Light cartridges contain a moderately polar, silica-based bonded phase with weakly basic surface. The sorbent can be used as a polar sorbent with different selectivity for acidic/basic analytes or as a weak anion exchanges in aqueous medium below pH 8. Applications include extraction of phenols and phenolic pigments, petroleum fractionation, saccharides and drugs and metabolites. These cartridges have a distinctive finned outer body and a reduced internal diameter, which results in an interstitial volume about one-third that of the corresponding Plus-style cartridge. This design allows you to elute fractions in a minimal volume to improve recoveries and reduce solvent consumption, a benefit especially for applications where samples are limited or where excessive dilution is a concern.
XSelect HSS C18 SB Method Validation Kit, 100Å, 2.5 µm, 4.6 mm X 150 mm, 3/pkg, Silica, USP Class:L1 , 2 - 8 Ph Range, High Silanol Activity, 230 m2/g, Spherical , 8.5 % Carbon Load
Mass Spectrometry standard for system assessment. 2 X Horse Heart Myoglobin 2.5 mg ±0.125 mg 15 mL Clear Nalgene Bottle 1 X 715002043 Sample Preparation Document Certificate of Analysis
Resolve Silica Column, 90Å, 5 µm, 3.9 mm X 150 mm, Silica, USP Class:L3 , 2 - 8 Ph Range, High Silanol Activity, 200 m2/g, Spherical
Amino Acid Analysis (AAA) is required for many applications. AccQ-Tag Eluent B Concentrate is available to purchase separetely in a 1 X 1L format. This Eluent is for use with multi-pump gradient systems.
Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.
Spherisorb Phenyl columns contains a non-endcapped silica-based Phenyl phase that provides unique compound selectivity for reversed-phase applications.
DisQuE Quechers ,Cleanup Tube, AOAC Method, 150 mg MgSO4, 50 mg PSA, and 50 mg C18, 2 mL Tube, Mass Spec Compatible
This method validation kit consists of three batches of XSelect HSS Cyano columns packed with three different batches of sorbent
The MassPREP on-line desalting column can effectively desalt proteins prior to LC-MS analyses. Because non-volatile salts (e.g., NaCl) can suppress ionization of intact proteins leading to poor detection sensitivity, it is important to remove or significantly minimize the introduction of these compounds into the mass analyzer. The reversed-phase phenyl material contained in MassPREP on-line column successfully “traps” proteins, allowing the salts to be washed to waste prior to protein elution into the mass spectrometer. With an optimized LC-MS method, cycle times as low as 4 minutes (for intact antibody) and 10 minutes (for reduced antibody) are achievable. NOTE: UPLC Intact Mass Analysis Application Kit** (Includes MassPREP Micro Desalting Column and ACQUITY Tubing Kit)
These vials are produced to tight dimensional tolerance for use in autosamplers.
XSelect HSS T3 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream.
The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
· Connect any 1/16-inch tubing (PEEK, stainless steel, titanium, or Tefzel) · Low dead volume · 10–32 thread
Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.
2.1 mm x 10 mm Holder Kit for Cartridges and Guard Columns
The Extractables & Leachables Screening Standard is designed to complement the Waters Screening Platform Solution with UNIFI™. This mix is composed of 18 common polymer additives allowing users to evaluate and benchmark high resolution LC-MS systems. The Extractables & Leachables Screening Standard covers a mass range of up to 1176 Da, supporting both positive and negative ionization modes. Compounds were specifically chosen due to stable retention times and easy evaluation of mass accuracy. Simplify your screening workflow and eliminate time consuming standard preparation steps when analyzing samples for unknown contaminants. The standard mix is provided in a Waters Crimp Top vial for direct injection and contains the following compounds in 2 mL MeOH. • Irganox 1010 (1 µg/ml+/- 1%) • Irganox 245 (0.1 µg/ml+/- 1%) • Irganox 1076 (1 µg/ml+/- 1%) • Irganox 1098 (0.1 µg/ml+/- 1%) • Cyasorb 2908 (0.1 µg/ml+/- 1%) • Uvinul 3030 (0.1 µg/ml+/- 1%) • Propylparaben (0.1 µg/ml+/- 1%) • Ethanox 330 (Irganox 1330) (1 µg/ml+/- 1%) • Tinuvin 327 (1 µg/ml+/- 1%) • Diethyl phthalate (0.1 µg/ml+/- 1%) • Diphenyl phthalate (0.1 µg/ml+/- 1%) • Tris(p-cresyl) phosphate (TCP) (0.1 µg/ml+/- 1%) • 2-hydroxy-4-octyloxy benzophenone (0.1 µg/ml+/- 1%) • Tinuvin P (1 µg/ml+/- 1%) • Uvitex OB (0.1 µg/ml+/- 1%) • Tinuvin 360 (1 µg/ml+/- 1%) • Dibutyl sebacate (0.1 µg/ml+/- 1%) • Methylparaben (0.1 µg/ml+/- 1%) Store at 4°C ± 2°C (Refrigerated)
The non-endcapped Resolve packings are significantly different from Waters’ other packing materials. The change in chromatographic behavior is most commonly noticed with polar compounds which are typically more retained.
Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.
The Oasis sorbent selection flangeless cartridge kit is specifically designed for rapid development of SPE methods for LC/MS analysis. The kit contains 40 cartridges — 10 each of the appropriate Oasis mixed-mode, ion-exchange chemistry: MAX (strong anion exchanger), WAX (weak anion exchanger), MCX (strong cation exchanger), and WCX (weak cation exchanger). Sample preparation method development can be quickly and easily achieved with the use of only two SPE protocols using these chemistries.
Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.
The HDMS Standard Kit - Reversed Peptide Kit contains three well characterized samples intended to calibrate ion mobility spectrometry/mass spectrometry (IMS/MS) systems. Additionally, this standard can be utilized as a reference standard for verifying IMS/MS system performance. The kit contains the following three components: 1 vial Ser-Asp-Gly-Arg-Gly, 1 mg in a 4 mL Amber Glass Screw Top Vial 1 vial Gly-Arg-Gly-Asp-Ser, 1 mg in a 4 mL Amber Glass Screw Top Vial 1 vial Poly-DL-Alanine, 1 mg in a 4 mL Amber Glass Screw Top Vial Store at -20ºC ± 10°C (Frozen)
The Pico Tag™ Method has been widely used for amino acid analysis for over two decades PicoTag Eluent A, used in the Waters Pico Tag™ Method, is sold separetly. This eluent is in a 4 x 1 L format.
Mass Spectrometry Standards Kit is used to perform operational and performance qualification on both single and triple quadrupole MS instruments, such as the SQD and TQD and many others. The MS detector linearity and detector limit can be tested with these standards. The kit contains a total of 7 solutions including: (2) 1 mg/mL sulfadimethoxine in methanol, 10 mL. For qualification, dilutions of sulfadimethoxine can be used to perform injector linearity and accuracy, MS detector linearity, system precision, flow rate linearity, carryover. It can also be used to check reproducibility, sensitivity, peak width, signal to noise, etc. on the MS. 1 mg/mL of each terfenadine, reserpine, acetominophen and caffeine in acetonitrile, 10 mL. A combination of the stock solutions provided can also used to perform gradient testing. Note that since all stock solutions are individually provided in 1 mg/mL concentrations, all compounds listed can be mixed and matched according to one's preference. Formic acid, 10 mL. Formic Acid is used as a modifier in solvents.
Styragel HMW columns are packed with a 20 µm particle and utilize a special 10 µm frit to minimize polymer shearing, making them ideal for use in high-molecular weight applications.
Red, 12 x 32mm Snap Neck Cap Neck Cap and PTFE/silicone Septum, suitable for Agilent Beckman Dynatech Finnigan Fisons Gilson Hitachi LDC L.E.A.P. Perkin-Elmer Spark Spectra-Physics Varian Waters 2695 Waters 2795, Vial
Sugar-Pak I Guard-Pak Insert, 10 µm, USP Class:L19
Replacement Filter Assembly for 3.0 mm, 3.9 mm, and 4.6 mm Columns 0.5 µm Porosity,
XTerra Shield RP18 Prep Guard Cartridge, 125Å, 10 µm, 7.8 mm X 10 mm, 1/pkg, Hybrid, USP Class:L1 , 2 - 12 Ph Range, Low Silanol Activity, 175 m2/g, End Capped , Spherical , 15 % Carbon Load
A unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for non-aqueous molecular weight determination. Polymethylmethacrylate Mid . Molecular Weight Kit 10 Vials, 0.5g in each vial containing the following moleculare weight standards: 2400, 9500, 31000, 52000, 100000, 170000, 270000, 490000, 730000, 1000000
Styragel HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterizing samples in the low to mid molecular range where high resolution is critical.
preslit PTFE/silicone Septum, suitable for Agilent Beckman Dynatech Finnigan Fisons Gilson Hitachi LDC L.E.A.P. Perkin-Elmer Spark Spectra-Physics Varian Waters 2695 Waters 2795 Waters Acquity Vial
SPE Accessories, Vacuum Manifold Accessories
Standard used for Mass Spec calibration assessment. NaCsI: Sodium Iodide 2ug/ul, +1%, -0% Cesium Iodide 50ng/ul, +1%, -0% in 50/50 IPA/Water 15 mL Nalgene Bottle
Porapak Q, 26 grams, Gas Chromatography Packings, GC Column Packing Materials
Sep-Pak AC2 Plus Short cartridges contain low ash content activated carbon for applications such as the concentration of pesticides and herbicides in water or food samples. Sep-Pak AC2 is used in Japan Pesticide Method #17. These short body cartridges can attach easily to pumps and syringes for reliable, positive-pressure flow to speed up the sample processing time. They can also be fitted with removable reservoirs and used on vacuum-assisted flow devices and certain automated systems.
Scale SFC from analytical to preparative with Torus Columns. Torus column chemistries (Torus 2-PIC, Torus DIOL, Torus DEA and Torus 1-AA) offer a wide range of selectivity and are offered in 1.7 µm and 5 µm analytical and 5 µm preparative column formats.
O-RING CARTRIDGE TOP 25MM, Radial Compression, LC Column Supplies
This kit includes the GlycoWorks Deglycosylation Module, GlycoWorks Labeling Module, GlycoWorks Clean-up Module, and the GlycoWorks Sample Collection Module. It contains materials to process 24 samples in a 3x8 format. The kit contains: GlycoWorks Deglycosylation Module: (1) 0.035 ml/vial Rapid PNGaseF Enzyme (1) 0.25 ml/vial Glycoworks Rapid Buffer (1) 3 vials of 3 mg/vial RapiGest™ SF Surfactant (1) Intact mAb Mass Check Standard *Shipped in a separate box GlycoWorks RapiFluor-MS™ Labeling Module: (3) 9 mg/vial RapiFluor-MS Reagent (3) 1 ml/vial Reagent Solvent (Anhydrous DMF) GlycoWorks RFMS Clean-up Module: (4) 0.5 ml/vial Elution Buffer (200mM Ammonium Acetate 95/5 Water/ACN pH 7) (4) 3 ml/vial Sample Diluent (DMF/ACN Mixture) (1) GlycoWorks HILIC µElution Plate GlycoWorks Sample Collection Module: (15) 1 mL tubes for deglycosylation and labeling reaction (15) 600 µL tube inserts for SPE eluate collection (15) Cap strips with slits for direct injection (1) 1 mL round collection tray (1) Waste tray
Alliance HPLC standards kit for system verification. Kit contains standards appropriate for verification of system reproducibility, detector gain linearity, injector accuracy,injector carryover.
The Hi3 Ecoli and Phos B standards are a specialized set of 6 synthetically prepared and highly purified peptides that provide the top 6 ionizing peptides of both the E.coli ClpB and rabbit Phosphorylase B proteins. These standards are quantitated via AAA to equimolar ratios to provide greater accuracy to each analysis. They are greater than 95% pure and have been verified by mass identification. These standards are primarily intended for use with the Hi3 quantification method for MSE proteomics data processed with ProteinLynx Global Server. The E. coli standard is intended for samples of animal origin, and the Phos B standard is intended for samples of microbial origin. The standards may also be of use in the evaluation and benchmarking of proteomic LC/MS systems comprised of nanoACQUITY UPLC and Synapt and Xevo time-of-flight mass spectrometers.
Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.
LCGC Certified Clear Glass 8 x 40 mm Snap Neck Total Recovery Vial, with Polyethylene Septumless Cap, 700 µL Volume, for Waters 700 Series
Standards Kit for Waters Prep 100 SFC system assessment.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.