Click-On In-Line Super-Clean Connectors Click-On connectors allow you to change traps quickly, without introducing oxygen into your system. Each connector is 2 3/8" (6 cm) in length.
Replacement Chemical Traps for Agilent GCs • Easy to install. • Attach to same fittings as original manufacturer',s equipment. • Built-in frits retain fine particles, adsorbents remove both moisture and hydrocarbons.
Super-Clean Click-on Trap Complete Helium Specific Gas Filter Kit, 1/4" Brass, Includes 2 Connectors and 1 Triple Trap, Oxygen/Moisture/Hydrocarbons
Base plates can be mounted by using screws and the mounting holes on the base plate, or by using this optional wall mounting bracket.
Super-Clean Gas Filters Filter Bundle, 1 Triple Filter and 2 Fuel Gas Filters Uses 3 Position Baseplate
Click-On Big Trap Triple Standard Replacement Filter
High-Capacity Oxygen Trap • Removes up to 600 mg of oxygen or 2 g of water. • Long life–typically purifies more than five 200 ft3 cylinders. • Reduces oxygen to 15 ppb. • Maximum operating pressure: 250 psi (1,724 kPa). • Flow: 3 L/min @ 32 psi (221 kPa).
Indicating Oxygen Trap •Removes oxygen to low ppb levels from He, Ar, N2, or methane. •Indicator changes from green to gray when adsorption capacity is depleted. •Can be used with nonoxidizing gases such as He, Ar, N2, H2, or CH4. •Heavy-walled inner glass tube is protected by a sealed outer plastic tube to prevent oxygen and water infusion. •Prepurged for fast stabilization. •100 psi (689 kPa) maximum operating pressure. •Reduces oxygen to 100 ppb. •10 μm frits at inlet and outlet. •Optimal flow rate: < 150 mL/min
Triple Helium Kit, 1/4" Includes: (2) 1/4" SS connectors, (1) oxygen/moisture/hydrocarbon helium-specific trap, and (2) wall-mounting clamps
Capillary-Grade Hydrocarbon Trap •Packed with an extremely high surface area, baked coconut shell–based activated carbon. •Purged with ultra-high purity helium. •Reduces organics to 0.1 ppm (assuming 100 ppm input). •Maximum operating pressure: 250 psi (1,724 kPa).
Super-Clean Click-on Trap Replacement Trap for FID Fuel Gas, Moisture and Hydrocarbons. Note: Replacement trap only–fittings sold separately.
Replacement Chemical Traps for Agilent GCs • Easy to install. • Attach to same fittings as original manufacturer',s equipment. • Built-in frits retain fine particles, adsorbents remove both moisture and hydrocarbons.
Super-Clean Gas Filters Complete Carrier Gas Filter Kit. Baseplate and Triple Filter. Oxygen, Moisture and Hydrocarbon trap (1/8")
VICI® Mat/Sen® Gas-Specific Purifier Modules • Replace separate oxygen, moisture, and hydrocarbon traps with one multiple-bed purifier, specific for purifying helium, hydrogen, nitrogen, or air. • Reduce gas impurities from ppm to low ppb levels. • Decrease baseline noise and increase GC-MS sensitivity. • Prepurged with the specified gas to shorten downtime.
VICI® Mat/Sen® Gas-Specific Purifier Modules • Replace separate oxygen, moisture, and hydrocarbon traps with one multiple-bed purifier, specific for purifying helium, hydrogen, nitrogen, or air. • Reduce gas impurities from ppm to low ppb levels. • Decrease baseline noise and increase GC-MS sensitivity. • Prepurged with the specified gas to shorten downtime.
Super-Clean Click-on Trap Replacement Hydrocarbon Trap Ultra High Capacity. Note: Replacement trap only–fittings sold separately.
Super-Clean Click-on Trap Replacement Helium Specific Triple Trap Oxygen/Moisture/Hydrocarbon
Rechargeable Molecular Sieve S-Trap • Traps water vapor, increases column and oxygen trap lifetime. • Reduces baseline noise from sensitive detectors such as ECDs and mass spectrometers. • Activated and ready to use. • Reduces water to less than 1 ppm. • Fits in GC oven for easy thermal recharging. • Maximum flow: 1 L/min.
Click-On In-Line Super-Clean Indicating Cartusche •Oxygen: green to grey •Moisture: beige to clear •Install an indicator after the Click-On in-line gas filter so there is no confusion about when to replace the traps. •Click-On traps measure: 8 1/2" x 1 1/4" (21.6 x 3.2 cm) •Note: Fittings sold separately.
• Removes hydrocarbons and other contaminants. • Reduces organics to 0.1 ppm (assuming 100 ppm input). • Each individually activated to ensure maximum efficiency. • Fits in GC oven for easy thermal recharging. • Maximum operating pressure: 60 psi (414 kPa).
Super-Clean Gas Filters Complete Helium Specific GC/MS Filter Kit. Base Plate & Triple Filter Oxygen,Moisture and Hydrocarbon (1/8")
Click-On In-line Super Clean Double Connector, Stainless Steel.
Super-Clean Gas Filter • High-purity output ensures 99.9999% pure gas (at max. fl ow of 2 L/min). • “Quick connect” fi ttings for easy, leak-tight cartridge changes. • Glass inside to prevent diff usion; polycarbonate housing outside for safety. • All traps measure 10 5/8" x 1 3/4" (27 x 4.4 cm). • Each base plate unit measures 4" x 4" x 1 7/8" (10.2 x 10.2 x 4.8 cm).
Super-Clean Gas Filters Charcoal Replacement Filter for LC/MS Trap, 2PK
Soft-Side Storage Case for Restek ProFLOW 6000 Electronic Flowmeter or Leak Detector Optional soft-side storage case is ideal for storing your flowmeter or leak detector in smaller spaces, such as your tool box.
Super-Clean Gas Filters FID Fuel Gas Filter Kit Baseplate + Hydrocarbon & Moisture Filters (1/8")
Maintenance Kits for Parker Balston® Zero Air Generators (includes a one-year supply of prefilters and final filter)
24 Month Maintenance Kit for H2 PEM Generators, Includes: 1 Deionizer Cartridge, 1 Water Filter, 3 Environmental Filters,1 Float (water level sensor),1 Water Pump,1 Desiccant Cartridge, Domestic orders drop ship from manufacturer via UPS
Replacement Gas Filters for Restek Super Clean Gas Filter Kits •High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min). •Designed for easy, hassle-free cartridge changes. •Glass inside to prevent diffusion, polycarbonate housing outside for safety. •The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.
VICI® Mat/Sen® Gas-Specific Purifier Modules • Replace separate oxygen, moisture, and hydrocarbon traps with one multiple-bed purifier, specific for purifying helium, hydrogen, nitrogen, or air. • Reduce gas impurities from ppm to low ppb levels. • Decrease baseline noise and increase GC-MS sensitivity. • Prepurged with the specified gas to shorten downtime.
6 Month Maintenance Kit for H2 PEM Generators, Kit Includes: 1 Deionizer Cartridge, 1 Water Filter, 3 Environmental Filters
Super-Clean Click-on Trap Replacement Triple Trap for Carrier Gas, Oxygen, Moisture, and Hydrocarbons. Note: Replacement trap only–fittings sold separately.
Replacement Gas Filters for Restek Super Clean Gas Filter Kits •High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min). •Designed for easy, hassle-free cartridge changes. •Glass inside to prevent diffusion, polycarbonate housing outside for safety. •The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.
Parker Balston® Zero Air Generators • Turn in-house compressed air into ultra-pure air (<0.1 ppm total hydrocarbons). • Remove hydrocarbons to less than 0.1 ppm by catalytic oxidation. • Operate at 40–125 psi (276–862 kPa). • Typical payback is less than one year, based on cylinder costs. • Install easily and take up little bench space*. • Maintenance kits include a one-year supply of prefilters and final filter.
Indicating Moisture Trap • Reduces water to less than 10 ppb; indicator changes from yellowish-green to blue at 5% relative humidity. • Prepurged for fast stabilization. • Reduces noise from high-sensitivity detectors. • Heavy-walled glass body prevents oxygen and water infusion. • 10 μm frit prevents microparticulate damage to needle valves and flow controllers. • Maximum operating pressure: 100 psi (689 kPa).
Super-Clean Click-on Trap Replacement Oxygen Trap Ultra High Capacity. Note: Replacement trap only–fittings sold separately.
ECD Vent Trap •Reduces the release of hazardous materials from the ECD vent into the lab. •Includes connecting lines and mounting kit. •Dimensions: 6" x 1" (15.2 x 2.5 cm)
Super-Clean Gas Filter • High-purity output ensures 99.9999% pure gas (at max. fl ow of 2 L/min). • “Quick connect” fi ttings for easy, leak-tight cartridge changes. • Glass inside to prevent diff usion; polycarbonate housing outside for safety. • All traps measure 10 5/8" x 1 3/4" (27 x 4.4 cm). • Each base plate unit measures 4" x 4" x 1 7/8" (10.2 x 10.2 x 4.8 cm).
Leak Detector Conformance Check. Unit Tested and Certified PO & SRV #s Required, INTERNATIONAL RETURNS: No more than 2 LD units per shipping box
Replacement Chemical Traps for Agilent 5890 GCs • Easy to install. • Attach to same fittings as original manufacturer',s equipment. • Built-in frits retain fine particles, adsorbents remove both moisture and hydrocarbons.
Hydrocarbon Kit, 1/4" Includes: (2) 1/4" SS connectors, (1) oxygen/moisture/hydrocarbon trap, and (2) wall-mounting clamps
Replacement Gas Filters for Restek Super Clean Gas Filter Kits •High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min). •Designed for easy, hassle-free cartridge changes. •Glass inside to prevent diffusion, polycarbonate housing outside for safety. •The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.
High-Capacity Moisture Trap • Purged with ultra-high-purity helium, ready to use. • Reduces water to less than 15 ppb. • Maximum operating pressure: 250 psi (1,724 kPa). • Maximum flow: 1.25 L/min.
Super-Clean Gas Filter • High-purity output ensures 99.9999% pure gas (at max. fl ow of 2 L/min). • “Quick connect” fi ttings for easy, leak-tight cartridge changes. • Glass inside to prevent diff usion; polycarbonate housing outside for safety. • All traps measure 10 5/8" x 1 3/4" (27 x 4.4 cm). • Each base plate unit measures 4" x 4" x 1 7/8" (10.2 x 10.2 x 4.8 cm).
High-Capacity Split Vent Trap • Reduces the release of hazardous materials from the capillary split vent into the lab. • Includes connecting lines and mounting kit.
In-line Gas Purifiers without indicator
Carbon Dioxide Trap •Removes carbon dioxide from inert gases He, Ar, N2, H2, and clean dry air (CDA) to low ppb levels. •Functions by consuming carbon dioxide in a reaction with highly dispersed NaOH on a silicate support (reaction produces water that remains adsorbed in the purifier). •In highly critical applications, consider using an additional moisture trap after the CO2 trap as a safety measure.
Indicating Detector Gas Purifier •Removes moisture and hydrocarbons (C5 and heavier) from dry air or inert gases. •Indicator signals breakthrough by changing from yellowish green to blue at low relative humidity to warn of leaks in the gas stream. •The inner glass tube contains activated carbon, moisture indicator, and molecular sieve. •10 μm frits at both ends of the filter. •Heavy-walled inner glass tube is protected by a sealed outer plastic tube to further protect against leaks.
Indicating Carrier Gas Purifier •Removes multiple impurities such as O2, H2O, CO2, CO, halogenated compounds, siloxanes, hydrocarbons (heavier than butane), sulfur-containing molecules, and ammonia from inert gases (He, Ar, N2, and H2). •Can be used with other filters to provide endpoint detection. •Contains highly sensitive visual indicators for oxygen and water contamination. The oxygen indicator signals breakthrough when the adsorbent changes from green to grey, and the moisture indicator signals breakthrough by changing from blue to brown. •Heavy-walled inner glass tube is protected by a sealed outer plastic tube to further protect against leaks.
Electronic Leak Detector. Includes carrying case, universal AC power adaptor [U.S., UK, Europe, Australia, Japan], 6-ft USB charging cable New and improved! Prevent small leaks from causing big problems with a Restek leak detector. •Detects a broad range of gases and indicates leak severity with both an LED display and audible tone. •No more waiting for a full charge—can be operated during charging or used up to 12 hours between charges. •Charging kit includes both universal AC power adaptor and USB charging cable so you can charge anywhere, anytime. •Pinpoint very small gas leaks quickly and accurately before they cause damage and downtime. •Compact, handheld unit is easy to operate and convenient to use anywhere you need to check for leaks.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.
Please fill out your contact data and your information request, we will contact you as soon as possible with all requested information.