Wagner & Munz GmbH makes use of Cookies
to be able to adapt the website to the needs of our users. If you continue using this page, you agree that cookies can be used for this purpose. Click here for further information.Accept
Calibration kit Polybutadiene-1.4, nominal Mp 1,070 - 1,020,000 Da. Includes 10 different Polybutadiene-1.4 individual molar mass standards, nominal Mp 1,000 - 1,000,000 g/mol, 10 x 1.0 g
NOVEMA Max columns are made of NH-functionalized acrylate copolymer. These columns are suitable for the aqueous GPC/SEC analysis of cationic polymers, such as polymeric quaternary ammonium compounds, poly(DADMAC), polyvinylpyridine, chitosan, and poly(ethylene imine), with molecular weights ranging from 100 to 30,000,000 Da. Available in two particle sizes and different porosities as well as linear/mixed-bed options, NOVEMA Max columns are flexible to meet a variety of application needs.
NOVEMA Max columns meet USP L23, tolerate high buffer concentrations, pH 2 to 12, temperatures up to 80 °C, and organic solvents (up to 100% methanol or acetonitrile).
ReadyCal-Kit PEG, nominale Mp 232 – 44 000 Da. Enthält 10 x 3 verschiedene Fläschchen mit abgewogenen Standards mit 4 verschiedenen Molmassen, 10 x 3 Fläschchen, 1,5 ml
Calibration kit Poly(L-lactic acid), nominal Mp 358 - 101,000 Da. Includes 8 different Poly(L-lactic acid) individual molar mass standards, nominal Mp 500 - 101,000 Da g/mol, 7 x 0.2 g and 1 x 0.5g
Add an additional concurrent user to WinGPC Client/Sever setup. The license representsa one concurrent user. Add as many as required. Only Compatible with G7890AC and G7890AD. Consult a GPC Product Specialist prior to quoting to customer
SUPREMA columns are ideal for the aqueous GPC/SEC analysis of neutral and anionic polymers, such as PEO, PEG, pullulan, dextran, polyacrylamide, hyaluronic acid, polyacrylic acid, and carboxymethyl cellulose. These acrylate copolymer-based columns are available in three particle sizes, 3, 5, and 10 μm, individual porosities between 30 and 30,000 Å and different linear/mixed-bed columns, to meet a variety of applications needs, including polymers ranging from 100 to 30,000,000 Da.
SUPREMA columns meet USP L25, L37, L38, L39, tolerate high buffer concentrations, pH 2 to 12, temperatures up to 80 °C, and organic solvents (up to 100% methanol or acetonitrile).
TCC clamps for 8 mm id columns. 8 clamps for 8 mm (approximate) id columns, for use in SECcurity thermostatted column compartments TCC6000, TCC6500, TCC7000, or G7886A
Add an additional concurrent user to WinGPC Client/Sever setup. The license representsa one concurrent user. Add as many as required. Only Compatible with G7890AC and G7890AD. Consult a GPC Product Specialist prior to quoting to customer
EasyValid Validation Kit for organic applications. Includes calibration standards, 6 x 5 1.5 mL vials, one EasyValid column, WinGPC report layouts and import files, and comprehensive user documentation
GPC/SEC Standards.
Poly(α-methylstyrene) standards are well suited for organic GPC/SEC system and column calibration. Standards are offered as individual molecular weight standards from 1,500 to 850,000 Da.
ReadyCal Kit Pullulan, nominal Mp 180 - 708,000 Da. Includes 5 each of 3 different vials containing preweighed standards with 3 different molar masses, 3 x 5 vials, 1.5 mL
EasyValid Validation Kit for aqueous applications. Includes calibration standards, 6 x 5 1.5 mL vials, one EasyValid column, WinGPC report layouts and import files, and comprehensive user documentation
EasyValid Standards Kit, aqueous, 6 x 5 vials, 1.5 mL. Replacement Dextran/Pullulan standards kit includes 5 each of 6 different individual molar mass standards. Separation column and user documentation required for use, suitable for validations in aqueous solutions
MALDI Validation Standards Kit mixed, nominal Mp 4,320 - 6,530 Da. Includes one vial each of PS, PMMA, Poly(dimethylsiloxane), PEG, Poly(styrene sulfonic acid), nominal Mp 4,300 - 6,500 g/mol, 5 x 0.5 g
SDV columns are useful for a wide variety of polymer analyses in nonpolar and medium polar organic solvents. These GPC columns are made from a styrene-divinylbenzene copolymer network and are available in three particle sizes (3, 5, and 10 μm) and a range of porosities to meet many organic GPC and SEC polymer analysis needs, including for polystyrene, polyvinyl chloride, polycarbonate, elastomers, resins, and more. The molecular weight range for SDV columns is 100 to 30,000,000 Da. SDV columns meet USP L21.
ReadyCal Kit Polystyrene for HT GPC, nominal Mp 370 - 2,520,000 Da. Includes 10 each of 3 different vials containing preweighed standards with 4 different molar masses, 3 x 10 vials, 1.5 mL
GPC/SEC Standards.
Polypropylene glycol standards are suitable for organic GPC/SEC system and column calibration. Individual standards are available with molecular weights ranging from 76 to 4,500 Da.
GRAM columns can be used for organic GPC and SEC polymer analysis in polar organic solvents. These polyester copolymer-based GPC columns are available in a range of porosities, from 30 to 10,000 Å, and one linear/mixed-bed version to meet the needs for a variety of polymers with molar masses ranging from 100 to 50,000,000 Da, including for the analysis of polyurethane, polyimide, starches, cellulose, and other polar polymers.
Calibration kit Polystyrene medium low, nominal Mp 162 - 851,000 Da. Includes 12 different Polystyrene individual molar mass standards, nominal Mp 160 - 850,000 g/mol, 12 x 1.0 g
TCC clamps for 4 mm id columns. 8 clamps for 4 mm (approximate) id columns, for use in SECcurity thermostatted column compartments TCC6000, TCC6500, TCC7000, or G7886A
Calibration kit Polystyrene sulfonate sodium salt, nominal Mp 891 - 976,000 Da. Includes 10 different Polystyrene sulfonate sodium salt individual molar mass standards, nominal Mp 900 - 1,000,000 g/mol, 10 x 0.5 g
ReadyCal Kit PEG/PEO, nominal Mp 238 - 969,000 Da. Includes 10 each of 3 different vials containing preweighed standards with 3 or 4 different molar masses, 3 x 10 vials, 4 mL
Calibration kit PEG/PEO, nominal Mp 194 - 1,180,000 Da. Includes 12 different PEG/PEO individual molar mass standards, nominal Mp 190 - 1,100,000 g/mol, 12 x 0.5 g
ReadyCal Kit PEG, nominal Mp 232 - 44,000 Da. Includes 10 each of 3 different vials containing preweighed standards with 4 different molar masses, 3 x 10 vials, 1.5 mL
Agilent WinGPC 2D-GPC/SEC Analysis Add-On. Adds 2D-GPC/SEC calculation functionality to WinGPC Software. Not for standalone installation. Requires a WinGPC Software main Edition and an additional timebase (G7896AA). Not compatible with Client/Sever setup (G7890AA/AB only)
Polyisoprene standards are useful for organic GPC/SEC column and system validation. These individual standards are available with narrow molar mass distribution ranges from 800 to 1,000,000 Da. A calibration kit is also available, containing molecular weights from 1,000 to 1,100,000 Da.
Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC/SEC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone, and ethyl acetate. They also work well with more polar organic eluents, for example dimethylformamide, dimethylacetamide, and hexafluoroisopropanol. The molecular weights are selected to provide equidistant calibration points for greater accuracy.
Individual molecular weight standards are available from 102 to 15,000,000 Da, with options for both narrow and broad molar mass distribution standards. Convenient calibration kits are also available, including traditional kits, InfinityLab EasiVial kits, and ReadyCal kits.
Calibration kit Poly(methacrylic acid) sodium salt, nominal Mp 1,310 - 1,120,000 Da. Includes 10 different Poly(methacrylic acid) sodium salt individual molar mass standards, nominal Mp 1,300 - 1,100,000 g/mol, 10 x 0.5 g
EasyValid replacement column for aqueous applications, 8 x 300 mm. GPC/SEC column, reference materials (part number PSS-DXTVAL) and user documentation (included with kit PSS-DXTKITVAL) required for use, ships in water
Visco/LS Validation Standards Kit, dextran, nominal Mp 8,500 - 202,000 Da. Viscometry/Light Scattering Detector Dextran Validation Kit, includes 4 different individual molar mass standards, 4 x 0.5 g
ReadyCal Kit Dextran, nominal Mp 180 - 400,000 Da. Includes 5 each of 3 different vials containing preweighed standards with 3 different molar masses, 3 x 5 vials, 1.5 mL
ReadyVLS Kit Dextran/Pullulan broad and narrow. Includes 10 each of narrow and broad preweighed standards to determine, check, and fine-tune interdetector delay and calibration constants for light scattering detectors, viscometers and triple detection; 2 x 10 vials, 1.5 mL
Calibration kit Polypropylene glycol, nominal Mp 76 - 4,150 Da. Includes 7 different Polypropylene glycol individual molar mass standards, nominal Mp 70 - 4,000 g/mol, 7 x 1.0 g
Calibration kit Polyisobutylene, nominal Mp 390 - 674,000 Da. Includes 10 different Polyisobutylene individual molar mass standards, nominal Mp 400 - 670,000 g/mol, 10 x 0.25 g
ReadyCal Kit Polystyrene, nominal Mp 474 - 2,520,000 Da. Includes 10 each of 3 different vials containing preweighed standards with 4 different molar masses, 3 x 10 vials, 4 mL
NOVEMA Max columns are made of NH-functionalized acrylate copolymer. These columns are suitable for the aqueous GPC/SEC analysis of cationic polymers, such as polymeric quaternary ammonium compounds, poly(DADMAC), polyvinylpyridine, chitosan, and poly(ethylene imine), with molecular weights ranging from 100 to 30,000,000 Da. Available in two particle sizes and different porosities as well as linear/mixed-bed options, NOVEMA Max columns are flexible to meet a variety of application needs.
NOVEMA Max columns meet USP L23, tolerate high buffer concentrations, pH 2 to 12, temperatures up to 80 °C, and organic solvents (up to 100% methanol or acetonitrile).
ReadyCal Kit Polystyrene low, nominal Mp 266 - 66,000 Da. Includes 10 each of 3 different vials containing preweighed standards with 4 different molar masses, 3 x 10 vials, 1.5 mL
Update to latest version of WinGPC Software Client/Server Edition (G7890AC or G7890AD), Only available for updating Agilent WinGPC SW 1.0, Legacy PSS WinGPC versions not supported. Consult a GPC Product Specialist prior to quoting to customer
Calibration kit Poly(2-vinylpyridine), nominal Mp 620 - 2,890,000 Da. Includes 12 different Poly(2-vinylpyridine) individual molar mass standards, nominal Mp 500 - 2,700,000 g/mol, 12 x 0.5 g
Add an additional concurrent user to WinGPC Client/Sever setup. The license representsa one concurrent user. Add as many as required. Only Compatible with G7890AC and G7890AD. Consult a GPC Product Specialist prior to quoting to customer
GPC/SEC Standards.
Poly(2-vinylpyridine) standards are compatible with both aqueous and organic GPC/SEC for column and system calibration. Individual molar mass standards are available with molecular weights ranging from 500 to 2,500,000 Da, each standard contains a narrow molar mass distribution. For convenience, a calibration kit is also available with standards from 600 to 2,500,000 Da.
Dextran standards are the most commonly used reference standards for aqueous GPC/SEC column calibration. These individual standards are available with molar mass distribution ranges from 180 to 2,000,000 Da to suit a wide variety of application needs.
Dextran standards are also available as standards for membrane characterization, light scattering and viscometry validation kits, and traditional calibration kits. For more convenience, ReadyCal kits are also available with preweighed standards for fast, reproducible calibration curve generation.
ReadyCal Kit Polystyrene for HT GPC, nominal Mp 266 - 12,200,000 Da. Includes 5 each of 4 different vials containing preweighed standards with 4 different molar masses, 4 x 5 vials, 10 mL
POLEFIN columns are useful for high-temperature organic GPC/SEC analysis of polyolefins with molecular weights from 100 to 30,000,000 Da. These organic GPC columns are based on a modified styrene-divinylbenzene copolymer network and have a maximum temperature rating of 210 °C. POLEFIN GPC columns offer flexible configurations, including two particle sizes and two different linear/mixed-bed columns to meet the needs for a variety of polymer analyses, such as polyethylene, polypropylene, and other polyolefins.