POLEFIN columns are useful for high-temperature organic GPC/SEC analysis of polyolefins with molecular weights from 100 to 30,000,000 Da. These organic GPC columns are based on a modified styrene-divinylbenzene copolymer network and have a maximum temperature rating of 210 °C. POLEFIN GPC columns offer flexible configurations, including two particle sizes and two different linear/mixed-bed columns to meet the needs for a variety of polymer analyses, such as polyethylene, polypropylene, and other polyolefins.
Reversed-Phase HPLC Columns.
The Agilent Pursuit family of HPLC columns offers reliable performance in various common particle sizes and phase chemistries, including USP L1, USP L7, and USP L11. Pursuit columns are available in many dimensions, including preparative HPLC columns. In addition, both traditional (Pursuit) and high carbon load (Pursuit XRS) bondings are available.
Features
Wide range of common particle sizes and phase chemistries, including USP L1, USP L7, and USP L11
Available in many dimensions, including preparative HPLC columns
Includes both traditional (Pursuit) and high carbon load (Pursuit XRS) bondings
Polyisoprene standards are useful for organic GPC/SEC column and system validation. These individual standards are available with narrow molar mass distribution ranges from 800 to 1,000,000 Da. A calibration kit is also available, containing molecular weights from 1,000 to 1,100,000 Da.
The Agilent ZORBAX column family is one of the most popular HPLC column families for reversed-phase HPLC. ZORBAX columns are based on traditional fully porous particles and offer the highest loading capacity and resolution.
GPC/SEC Standards.
Polyvinylpyrrolidone standards are available as broad range molecular weight standards. The standards range from a nominal molar mass of 3,000 to 1,000,000 Da with PDI greater than 1.50 and are suitable for aqueous GPC/SEC column and system calibration.
GPC/SEC Standards
Poly(styrene sulfonic acid) standards can be used for aqueous GPC/SEC for column and system calibration. These standards are particularly useful when UV detection is your only available option. Poly(styrene sulfonic acid) standards come in a wide range of molecular weights from 246 to 3,200,000 Da
LCCCValid Validation Kit, PEG with column, standards, and documentation. Includes column, documentation, 3 vials each of 4 different PEG standards with allyl and methyl end functionality, and 6 each of 3 vials containing PEG with different molar masses, 1.5 mL
Agilent WinGPC 3D Spectra Add-On. Adds 3D Spectra capabilities (e.g., DAD spectra) to WinGPC Software. Not for standalone installation. Requires a WinGPC Software main Edition
GPC/SEC Standards.
Poly(styrene sulfonic acid) standards can be used for aqueous GPC/SEC for column and system calibration. These standards are particularly useful when UV detection is your only available option. Poly(styrene sulfonic acid) standards come in a wide range of molecular weights from 246 to 3,200,000 Da, with broad range standards and calibration kits also available.
MCX columns are suitable for the aqueous GPC/SEC analysis of strong polyanions such as poly(styrene sulfonate), lignin sulfonate, modified starches, acids, alcohols, and pectins. This sulfonated styrene-divinylbenzene copolymer-based GPC column can be used for sulfonated polymers with molar masses ranging from 100 to 5,000,000 Da and are available in two particles sizes with a range of porosities to meet your polymer analysis needs.
MCX columns meet USP L22, tolerate high buffer concentrations, pH 1 to 13, temperatures up to 80 °C, and organic solvents (up to 100% methanol or acetonitrile).
SUPREMA columns are ideal for the aqueous GPC/SEC analysis of neutral and anionic polymers, such as PEO, PEG, pullulan, dextran, polyacrylamide, hyaluronic acid, polyacrylic acid, and carboxymethyl cellulose. These acrylate copolymer-based columns are available in three particle sizes, 3, 5, and 10 μm, individual porosities between 30 and 30,000 Å and different linear/mixed-bed columns, to meet a variety of applications needs, including polymers ranging from 100 to 30,000,000 Da.
SUPREMA columns meet USP L25, L37, L38, L39, tolerate high buffer concentrations, pH 2 to 12, temperatures up to 80 °C, and organic solvents (up to 100% methanol or acetonitrile).
EasyValid replacement column for organic applications, 8 x 300 mm. GPC/SEC column, reference materials (part number PSS-PSVAL) and user documentation (included with kit PSS-PSKITVAL) required for use, ships in THF
GPC/SEC Standards.
Polyethylene Glycol, Polyethylene Oxide Standards.
These hydrophilic polymers are suitable for both aqueous and organic GPC/SEC using most polar organic solvents. The polyethylene oxides (PEO) are available in high molecular weights, while the polyethylene glycols (PEG) cover the lower molecular weight range. The two types are chemically similar so they can be used together across a wider molecular weight range, with individual molecular weight aqueous and organic polymer standards from 62 to 1,300,000 Da.
Agilent WinGPC Mass Spectrometry Analysis Add-On. Adds MS calculation functionality to WinGPC Software. Not for standalone installation. Requires a WinGPC Software main Edition
Update to latest version of WinGPC Software workstation Edition (G7890AA or G7890AB)
Only available for updating Agilent WinGPC SW 1.0 Legacy PSS WinGPC versions not supported.
Poly(dimethylsiloxane) standards can be used to calibrate your organic GPC/SEC system and column. The individual molecular weight standards are available from 162 to 320,000 Da. For convenience, a calibration kit is also available with molecular weights ranging from 311 to 300,000 Da.
Poly(methacrylic acid) standards are compatible with aqueous GPC/SEC. These individual standards can be used for column and system calibration. Molar masses for the standards range from 1,200 to 1,000,000 Da. Calibration kits are also available.
Polystyrene standards are the first choice for many organic solvents, either for conventional GPC/SEC column calibration or for calibrating light scattering and viscometry detectors. The molecular weights of our organic polymers are selected to provide equidistant calibration points for greater accuracy. Individual molecular weight standards are available from 162 to 15,000,000 Da, with options for broad molar mass distribution standards. Convenient calibration kits are also available, including traditional kits, InfinityLab EasiCal kits, and ReadyCal kits.
Adds an additional timebase for workstation control to an existing WinGPC Software License. Currently only one additional timebase per WinGPC main Edition possible. Only compatible with G7890AA or G7890AB
TCC clamps for 20 mm id columns. 4 clamps for 20 mm (approximate) id preparative columns, for use in SECcurity thermostatted column compartments TCC6000, TCC6500, TCC7000, or G7886A
Polyethylene Glycol, Polyethylene Oxide Standards
These hydrophilic polymers are suitable for both aqueous and organic GPC/SEC using most polar organic solvents. The polyethylene oxides (PEO) are available in high molecular weights, while the polyethylene glycols (PEG) cover the lower molecular weight range. The two types are chemically similar so they can be used together across a wider molecular weight range, with individual molecular weight aqueous and organic polymer standards from 62 to 1,300,000 Da.
Calibration kit Polystyrene high, nominal Mp 682 - 2,520,000 Da. Includes 12 different Polystyrene individual molar mass standards, nominal Mp 700 - 2,500,000 g/mol, 12 x 1.0 g
GPC/SEC Standards.
Poly(styrene sulfonic acid) standards can be used for aqueous GPC/SEC for column and system calibration. These standards are particularly useful when UV detection is your only available option. Poly(styrene sulfonic acid) standards come in a wide range of molecular weights from 246 to 3,200,000 Da, with broad range standards and calibration kits also available.
ReadyCal Kit Polystyrene low, nominal Mp 266 - 66,000 Da. Includes 10 each of 3 different vials containing preweighed standards with 4 different molar masses, 3 x 10 vials, 4 mL
Visco/LS Validation Standards Kit, PMMA, nominal Mp 8,200 - 903,000 Da. Viscometry/Light Scattering Detector PMMA Validation Kit includes 4 different individual molar mass standards, 4 x 0.5 g
Calibration kit Polyethylene, nominal Mp 338 - 78,400 Da. Includes 10 different Polyethylene individual molar mass standards, nominal Mp 330 - 78,000 g/mol, 10 x 0.25 g
GPC/SEC Standards.
Pullulan standards are commonly used for aqueous GPC/SEC column calibration. These individual polysaccharide reference standards are available with molar masses ranging from 342 to 1,000,000 Da. Pullulan calibration kits and ReadyCal kits are also available, with molecular weights up to 1,000,000 Da.
Calibration kit PMMA low, nominal Mp 102 - 62,200 Da. Includes 8 different Polymethylmethacrylate individual molar mass standards, nominal Mp 100 - 60,000 g/mol, 8 x 0.5 g
Calibration kit PMMA high, nominal Mp 602 - 3,060,000 Da. Includes 12 different Polymethylmethacrylate individual molar mass standards, nominal Mp 600 - 2,700,000 g/mol, 12 x 0.5 g
PolarSil columns are based on polar modified silica and ideal for the organic GPC/SEC separation of low to medium molar mass resins and lignins with molecular weights from 100 to 1,000,000 Da using polar organic solvents. Multiple column configurations are available to match your specific application, including two particle sizes, 3 and 5 μm, and three porosities, 100, 300, and 1,000 Å as well as two different linear/mixed-bed columns.
GPC/SEC Standards.
Polyethylene standards are compatible with high temperature organic GPC/SEC column and system calibration. These individual molecular weight standards are available from 800 to 120,000 Da. Additionally, a calibration kit is available with molecular weights ranging from 338 to 80,000 Da.
GPC/SEC Standards
Polybutadiene standards are suitable for organic GPC/SEC column calibration. These individual polymer standards are available with narrow molar mass distribution ranges, with molecular weights from 110 to 1,000,000 Da. Standards are also available in a calibration kit.
Polaris - Reversed Phase HPLC Columns.
Agilent Polaris HPLC columns offer many polar phase chemistries designed separate mixtures of polar and nonpolar analytes reliably and with excellent peak shapes. The polar-embedded C8 and C18 bonded phases are compatible with 100% water, and offer alternative selectivities while still complying with USP L1 and USP L7. The combination of high carbon load, ultrapure silica, and silanol shielding provides superior peak shape and retention with highly polar samples.
Visco/LS Validation Standards Kit, polystyrene, nominal Mp 9,130 - 556,000 Da. Viscometry/Light Scattering Detector Polystyrene Validation Kit includes 4 different individual molar mass standards, 4 x 0.5 g
MCX columns are suitable for the aqueous GPC/SEC analysis of strong polyanions such as poly(styrene sulfonate), lignin sulfonate, modified starches, acids, alcohols, and pectins. This sulfonated styrene-divinylbenzene copolymer-based GPC column can be used for sulfonated polymers with molar masses ranging from 100 to 5,000,000 Da and are available in two particles sizes with a range of porosities to meet your polymer analysis needs.
MCX columns meet USP L22, tolerate high buffer concentrations, pH 1 to 13, temperatures up to 80 °C, and organic solvents (up to 100% methanol or acetonitrile).
LCCCValid Standards Kit PEG, 6 x 3 and 3 x 4 vials, 1.5 mL. Includes 3 vials each of 4 different PEG standards with allyl and methyl end functionality, and 6 each of 3 vials containing PEG with different molar masses
ReadyCal Kit PMMA, nominal Mp 596 - 2,050,000 Da. Includes 10 each of 3 different vials containing preweighed standards with 4 different molar masses, 3 x 10 vials, 1.5 mL
Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC/SEC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone, and ethyl acetate. They also work well with more polar organic eluents, for example dimethylformamide, dimethylacetamide, and hexafluoroisopropanol. The molecular weights are selected to provide equidistant calibration points for greater accuracy.
Individual molecular weight standards are available from 102 to 15,000,000 Da, with options for both narrow and broad molar mass distribution standards. Convenient calibration kits are also available, including traditional kits, InfinityLab EasiVial kits, and ReadyCal kits.
Adds an additional timebase for workstation control to an existing WinGPC Software License. Currently only one additional timebase per WinGPC main Edition possible. Only compatible with G7890AA or G7890AB.
ReadyVLS Kit Polystyrene narrow. Includes preweighed standards for determination of interdetector delay and detector calibration constants for light scattering detectors, viscometers and triple detection systems, 10 Vials, 1.5 mL